Cargando…
Effects of applied potential and the initial gap between electrodes on localized electrochemical deposition of micrometer copper columns
Micrometer copper columns were fabricated via a technology named localized electrochemical deposition (LECD). This paper studies the effects of applied potential and the initial gap between electrodes on the LECD process. The surface and cross sectional morphologies, as well as the average depositio...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4869097/ https://www.ncbi.nlm.nih.gov/pubmed/27185742 http://dx.doi.org/10.1038/srep26270 |
_version_ | 1782432256303824896 |
---|---|
author | Wang, Fuliang Xiao, Hongbin He, Hu |
author_facet | Wang, Fuliang Xiao, Hongbin He, Hu |
author_sort | Wang, Fuliang |
collection | PubMed |
description | Micrometer copper columns were fabricated via a technology named localized electrochemical deposition (LECD). This paper studies the effects of applied potential and the initial gap between electrodes on the LECD process. The surface and cross sectional morphologies, as well as the average deposition rate were investigated to evaluate the quality of the deposited copper columns. Results demonstrated that the copper columns tended to be cylinder-shape with few voids inside at lower potential (<2.4 V). Whereas,the copper columns tended to be dendriform-shape with lots of voids inside at larger potential (>2.8 V). The average deposition rate increased with the raise of potential. In addition, the copper columns tended to be cylinder-shape with the initial gap between electrodes to be 10 μm or below. However, the copper columns tended to be cone-shape when the initial gap between electrodes became larger (35 μm or above). The number of voids inside the copper column and the average deposition rate both decreased with the increase of the initial gap. Moreover, the process of LECD under varied electric field has also been simulated using COMSOL software, and the formation of cylindrical and conical copper columns was further explained based on the electric field distribution at the cathode. |
format | Online Article Text |
id | pubmed-4869097 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-48690972016-06-01 Effects of applied potential and the initial gap between electrodes on localized electrochemical deposition of micrometer copper columns Wang, Fuliang Xiao, Hongbin He, Hu Sci Rep Article Micrometer copper columns were fabricated via a technology named localized electrochemical deposition (LECD). This paper studies the effects of applied potential and the initial gap between electrodes on the LECD process. The surface and cross sectional morphologies, as well as the average deposition rate were investigated to evaluate the quality of the deposited copper columns. Results demonstrated that the copper columns tended to be cylinder-shape with few voids inside at lower potential (<2.4 V). Whereas,the copper columns tended to be dendriform-shape with lots of voids inside at larger potential (>2.8 V). The average deposition rate increased with the raise of potential. In addition, the copper columns tended to be cylinder-shape with the initial gap between electrodes to be 10 μm or below. However, the copper columns tended to be cone-shape when the initial gap between electrodes became larger (35 μm or above). The number of voids inside the copper column and the average deposition rate both decreased with the increase of the initial gap. Moreover, the process of LECD under varied electric field has also been simulated using COMSOL software, and the formation of cylindrical and conical copper columns was further explained based on the electric field distribution at the cathode. Nature Publishing Group 2016-05-17 /pmc/articles/PMC4869097/ /pubmed/27185742 http://dx.doi.org/10.1038/srep26270 Text en Copyright © 2016, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Wang, Fuliang Xiao, Hongbin He, Hu Effects of applied potential and the initial gap between electrodes on localized electrochemical deposition of micrometer copper columns |
title | Effects of applied potential and the initial gap between electrodes on localized electrochemical deposition of micrometer copper columns |
title_full | Effects of applied potential and the initial gap between electrodes on localized electrochemical deposition of micrometer copper columns |
title_fullStr | Effects of applied potential and the initial gap between electrodes on localized electrochemical deposition of micrometer copper columns |
title_full_unstemmed | Effects of applied potential and the initial gap between electrodes on localized electrochemical deposition of micrometer copper columns |
title_short | Effects of applied potential and the initial gap between electrodes on localized electrochemical deposition of micrometer copper columns |
title_sort | effects of applied potential and the initial gap between electrodes on localized electrochemical deposition of micrometer copper columns |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4869097/ https://www.ncbi.nlm.nih.gov/pubmed/27185742 http://dx.doi.org/10.1038/srep26270 |
work_keys_str_mv | AT wangfuliang effectsofappliedpotentialandtheinitialgapbetweenelectrodesonlocalizedelectrochemicaldepositionofmicrometercoppercolumns AT xiaohongbin effectsofappliedpotentialandtheinitialgapbetweenelectrodesonlocalizedelectrochemicaldepositionofmicrometercoppercolumns AT hehu effectsofappliedpotentialandtheinitialgapbetweenelectrodesonlocalizedelectrochemicaldepositionofmicrometercoppercolumns |