Cargando…

Effects of applied potential and the initial gap between electrodes on localized electrochemical deposition of micrometer copper columns

Micrometer copper columns were fabricated via a technology named localized electrochemical deposition (LECD). This paper studies the effects of applied potential and the initial gap between electrodes on the LECD process. The surface and cross sectional morphologies, as well as the average depositio...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Fuliang, Xiao, Hongbin, He, Hu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4869097/
https://www.ncbi.nlm.nih.gov/pubmed/27185742
http://dx.doi.org/10.1038/srep26270
_version_ 1782432256303824896
author Wang, Fuliang
Xiao, Hongbin
He, Hu
author_facet Wang, Fuliang
Xiao, Hongbin
He, Hu
author_sort Wang, Fuliang
collection PubMed
description Micrometer copper columns were fabricated via a technology named localized electrochemical deposition (LECD). This paper studies the effects of applied potential and the initial gap between electrodes on the LECD process. The surface and cross sectional morphologies, as well as the average deposition rate were investigated to evaluate the quality of the deposited copper columns. Results demonstrated that the copper columns tended to be cylinder-shape with few voids inside at lower potential (<2.4 V). Whereas,the copper columns tended to be dendriform-shape with lots of voids inside at larger potential (>2.8 V). The average deposition rate increased with the raise of potential. In addition, the copper columns tended to be cylinder-shape with the initial gap between electrodes to be 10 μm or below. However, the copper columns tended to be cone-shape when the initial gap between electrodes became larger (35 μm or above). The number of voids inside the copper column and the average deposition rate both decreased with the increase of the initial gap. Moreover, the process of LECD under varied electric field has also been simulated using COMSOL software, and the formation of cylindrical and conical copper columns was further explained based on the electric field distribution at the cathode.
format Online
Article
Text
id pubmed-4869097
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-48690972016-06-01 Effects of applied potential and the initial gap between electrodes on localized electrochemical deposition of micrometer copper columns Wang, Fuliang Xiao, Hongbin He, Hu Sci Rep Article Micrometer copper columns were fabricated via a technology named localized electrochemical deposition (LECD). This paper studies the effects of applied potential and the initial gap between electrodes on the LECD process. The surface and cross sectional morphologies, as well as the average deposition rate were investigated to evaluate the quality of the deposited copper columns. Results demonstrated that the copper columns tended to be cylinder-shape with few voids inside at lower potential (<2.4 V). Whereas,the copper columns tended to be dendriform-shape with lots of voids inside at larger potential (>2.8 V). The average deposition rate increased with the raise of potential. In addition, the copper columns tended to be cylinder-shape with the initial gap between electrodes to be 10 μm or below. However, the copper columns tended to be cone-shape when the initial gap between electrodes became larger (35 μm or above). The number of voids inside the copper column and the average deposition rate both decreased with the increase of the initial gap. Moreover, the process of LECD under varied electric field has also been simulated using COMSOL software, and the formation of cylindrical and conical copper columns was further explained based on the electric field distribution at the cathode. Nature Publishing Group 2016-05-17 /pmc/articles/PMC4869097/ /pubmed/27185742 http://dx.doi.org/10.1038/srep26270 Text en Copyright © 2016, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Wang, Fuliang
Xiao, Hongbin
He, Hu
Effects of applied potential and the initial gap between electrodes on localized electrochemical deposition of micrometer copper columns
title Effects of applied potential and the initial gap between electrodes on localized electrochemical deposition of micrometer copper columns
title_full Effects of applied potential and the initial gap between electrodes on localized electrochemical deposition of micrometer copper columns
title_fullStr Effects of applied potential and the initial gap between electrodes on localized electrochemical deposition of micrometer copper columns
title_full_unstemmed Effects of applied potential and the initial gap between electrodes on localized electrochemical deposition of micrometer copper columns
title_short Effects of applied potential and the initial gap between electrodes on localized electrochemical deposition of micrometer copper columns
title_sort effects of applied potential and the initial gap between electrodes on localized electrochemical deposition of micrometer copper columns
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4869097/
https://www.ncbi.nlm.nih.gov/pubmed/27185742
http://dx.doi.org/10.1038/srep26270
work_keys_str_mv AT wangfuliang effectsofappliedpotentialandtheinitialgapbetweenelectrodesonlocalizedelectrochemicaldepositionofmicrometercoppercolumns
AT xiaohongbin effectsofappliedpotentialandtheinitialgapbetweenelectrodesonlocalizedelectrochemicaldepositionofmicrometercoppercolumns
AT hehu effectsofappliedpotentialandtheinitialgapbetweenelectrodesonlocalizedelectrochemicaldepositionofmicrometercoppercolumns