Comparison of intraocular pressure adjusted by central corneal thickness or corneal biomechanical properties as measured in glaucomatous eyes using noncontact tonometers and the Goldmann applanation tonometer

PURPOSE: To investigate the correlation coefficients between intraocular pressure (IOP) before and after adjusting for central corneal thickness (CCT) and corneal biomechanical properties. PATIENTS AND METHODS: A total of 218 eyes of 218 patients with primary open-angle glaucoma (mean age =71.5 year...

Descripción completa

Detalles Bibliográficos
Autores principales: Yaoeda, Kiyoshi, Fukushima, Atsushi, Shirakashi, Motohiro, Fukuchi, Takeo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4869658/
https://www.ncbi.nlm.nih.gov/pubmed/27274187
http://dx.doi.org/10.2147/OPTH.S106836
_version_ 1782432356722802688
author Yaoeda, Kiyoshi
Fukushima, Atsushi
Shirakashi, Motohiro
Fukuchi, Takeo
author_facet Yaoeda, Kiyoshi
Fukushima, Atsushi
Shirakashi, Motohiro
Fukuchi, Takeo
author_sort Yaoeda, Kiyoshi
collection PubMed
description PURPOSE: To investigate the correlation coefficients between intraocular pressure (IOP) before and after adjusting for central corneal thickness (CCT) and corneal biomechanical properties. PATIENTS AND METHODS: A total of 218 eyes of 218 patients with primary open-angle glaucoma (mean age =71.5 years; mean spherical equivalent =−0.51 D; mean deviation determined by Humphrey visual field analyzer =−3.22 dB) were included in this study. The tIOP and tIOPCCT, which were adjusted by the CCT (with tIOP meaning IOP not adjusted by CCT, as determined using the CT-1P; and tIOPCCT meaning IOP adjusted by CCT, as determined using the CT-1P), were determined using a noncontact tonometer. The IOPg and IOPCCT, which were adjusted by CCT, and IOPcc adjusted by corneal biomechanical properties were determined using a Reichert 7CR (with IOPg meaning IOP not adjusted by CCT or corneal biomechanical properties, as determined using the Reichert 7CR; IOPCCT meaning IOP adjusted by CCT, as determined using the Reichert 7CR; and IOPcc meaning IOP adjusted by corneal biomechanical properties, as determined using the Reichert 7CR). The GT and GTCCT adjusted by CCT were determined using a Goldmann applanation tonometer (with GT meaning IOP not adjusted by CCT, as determined using the Goldmann applanation tonometer; and with GTCCT meaning IOP adjusted by CCT, as determined using the GAT). Pearson’s correlation coefficients among the IOPs were calculated and compared. P-values <0.05 were considered as statistically significant. RESULTS: The tIOP, tIOPCCT, IOPg, IOPCCT, IOPcc, GT, and GTCCT were 14.8±2.5, 15.0±2.4, 13.1±3.2, 13.3±3.1, 13.7±2.9, 13.2±2.4, and 13.4±2.3 mmHg (mean ± standard deviation), respectively. The correlation coefficient between tIOPCCT and tIOP (r=0.979) was significantly higher than that between tIOPCCT and the other IOPs (r=0.668–0.852; P<0.001, respectively). The correlation coefficient between IOPCCT and IOPg (r=0.994) or IOPcc and IOPg (r=0.892) was significantly higher than that between IOPCCT or IOPcc and the other IOPs (r=0.669–0.740; P<0.001, respectively). The correlation coefficient between GTCCT and GT (r=0.989) was significantly higher than that between GTCCT and the other IOPs (r=0.669–0.740; P<0.001, respectively). CONCLUSION: The IOP adjusted by CCT or corneal biomechanical properties depends on the measurement instrument itself, rather than the adjustment methods, for eyes of patients with primary open-angle glaucoma.
format Online
Article
Text
id pubmed-4869658
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-48696582016-06-07 Comparison of intraocular pressure adjusted by central corneal thickness or corneal biomechanical properties as measured in glaucomatous eyes using noncontact tonometers and the Goldmann applanation tonometer Yaoeda, Kiyoshi Fukushima, Atsushi Shirakashi, Motohiro Fukuchi, Takeo Clin Ophthalmol Original Research PURPOSE: To investigate the correlation coefficients between intraocular pressure (IOP) before and after adjusting for central corneal thickness (CCT) and corneal biomechanical properties. PATIENTS AND METHODS: A total of 218 eyes of 218 patients with primary open-angle glaucoma (mean age =71.5 years; mean spherical equivalent =−0.51 D; mean deviation determined by Humphrey visual field analyzer =−3.22 dB) were included in this study. The tIOP and tIOPCCT, which were adjusted by the CCT (with tIOP meaning IOP not adjusted by CCT, as determined using the CT-1P; and tIOPCCT meaning IOP adjusted by CCT, as determined using the CT-1P), were determined using a noncontact tonometer. The IOPg and IOPCCT, which were adjusted by CCT, and IOPcc adjusted by corneal biomechanical properties were determined using a Reichert 7CR (with IOPg meaning IOP not adjusted by CCT or corneal biomechanical properties, as determined using the Reichert 7CR; IOPCCT meaning IOP adjusted by CCT, as determined using the Reichert 7CR; and IOPcc meaning IOP adjusted by corneal biomechanical properties, as determined using the Reichert 7CR). The GT and GTCCT adjusted by CCT were determined using a Goldmann applanation tonometer (with GT meaning IOP not adjusted by CCT, as determined using the Goldmann applanation tonometer; and with GTCCT meaning IOP adjusted by CCT, as determined using the GAT). Pearson’s correlation coefficients among the IOPs were calculated and compared. P-values <0.05 were considered as statistically significant. RESULTS: The tIOP, tIOPCCT, IOPg, IOPCCT, IOPcc, GT, and GTCCT were 14.8±2.5, 15.0±2.4, 13.1±3.2, 13.3±3.1, 13.7±2.9, 13.2±2.4, and 13.4±2.3 mmHg (mean ± standard deviation), respectively. The correlation coefficient between tIOPCCT and tIOP (r=0.979) was significantly higher than that between tIOPCCT and the other IOPs (r=0.668–0.852; P<0.001, respectively). The correlation coefficient between IOPCCT and IOPg (r=0.994) or IOPcc and IOPg (r=0.892) was significantly higher than that between IOPCCT or IOPcc and the other IOPs (r=0.669–0.740; P<0.001, respectively). The correlation coefficient between GTCCT and GT (r=0.989) was significantly higher than that between GTCCT and the other IOPs (r=0.669–0.740; P<0.001, respectively). CONCLUSION: The IOP adjusted by CCT or corneal biomechanical properties depends on the measurement instrument itself, rather than the adjustment methods, for eyes of patients with primary open-angle glaucoma. Dove Medical Press 2016-05-11 /pmc/articles/PMC4869658/ /pubmed/27274187 http://dx.doi.org/10.2147/OPTH.S106836 Text en © 2016 Yaoeda et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Yaoeda, Kiyoshi
Fukushima, Atsushi
Shirakashi, Motohiro
Fukuchi, Takeo
Comparison of intraocular pressure adjusted by central corneal thickness or corneal biomechanical properties as measured in glaucomatous eyes using noncontact tonometers and the Goldmann applanation tonometer
title Comparison of intraocular pressure adjusted by central corneal thickness or corneal biomechanical properties as measured in glaucomatous eyes using noncontact tonometers and the Goldmann applanation tonometer
title_full Comparison of intraocular pressure adjusted by central corneal thickness or corneal biomechanical properties as measured in glaucomatous eyes using noncontact tonometers and the Goldmann applanation tonometer
title_fullStr Comparison of intraocular pressure adjusted by central corneal thickness or corneal biomechanical properties as measured in glaucomatous eyes using noncontact tonometers and the Goldmann applanation tonometer
title_full_unstemmed Comparison of intraocular pressure adjusted by central corneal thickness or corneal biomechanical properties as measured in glaucomatous eyes using noncontact tonometers and the Goldmann applanation tonometer
title_short Comparison of intraocular pressure adjusted by central corneal thickness or corneal biomechanical properties as measured in glaucomatous eyes using noncontact tonometers and the Goldmann applanation tonometer
title_sort comparison of intraocular pressure adjusted by central corneal thickness or corneal biomechanical properties as measured in glaucomatous eyes using noncontact tonometers and the goldmann applanation tonometer
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4869658/
https://www.ncbi.nlm.nih.gov/pubmed/27274187
http://dx.doi.org/10.2147/OPTH.S106836
work_keys_str_mv AT yaoedakiyoshi comparisonofintraocularpressureadjustedbycentralcornealthicknessorcornealbiomechanicalpropertiesasmeasuredinglaucomatouseyesusingnoncontacttonometersandthegoldmannapplanationtonometer
AT fukushimaatsushi comparisonofintraocularpressureadjustedbycentralcornealthicknessorcornealbiomechanicalpropertiesasmeasuredinglaucomatouseyesusingnoncontacttonometersandthegoldmannapplanationtonometer
AT shirakashimotohiro comparisonofintraocularpressureadjustedbycentralcornealthicknessorcornealbiomechanicalpropertiesasmeasuredinglaucomatouseyesusingnoncontacttonometersandthegoldmannapplanationtonometer
AT fukuchitakeo comparisonofintraocularpressureadjustedbycentralcornealthicknessorcornealbiomechanicalpropertiesasmeasuredinglaucomatouseyesusingnoncontacttonometersandthegoldmannapplanationtonometer