Cargando…
ROM Plus(®): accurate point-of-care detection of ruptured fetal membranes
Accurate and timely diagnosis of rupture of fetal membranes is imperative to inform and guide gestational age-specific interventions to optimize perinatal outcomes and reduce the risk of serious complications, including preterm delivery and infections. The ROM Plus is a rapid, point-of-care, qualita...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4869842/ https://www.ncbi.nlm.nih.gov/pubmed/27274316 http://dx.doi.org/10.2147/MDER.S106106 |
_version_ | 1782432382256676864 |
---|---|
author | McQuivey, Ross W Block, Jon E |
author_facet | McQuivey, Ross W Block, Jon E |
author_sort | McQuivey, Ross W |
collection | PubMed |
description | Accurate and timely diagnosis of rupture of fetal membranes is imperative to inform and guide gestational age-specific interventions to optimize perinatal outcomes and reduce the risk of serious complications, including preterm delivery and infections. The ROM Plus is a rapid, point-of-care, qualitative immunochromatographic diagnostic test that uses a unique monoclonal/polyclonal antibody approach to detect two different proteins found in amniotic fluid at high concentrations: alpha-fetoprotein and insulin-like growth factor binding protein-1. Clinical study results have uniformly demonstrated high diagnostic accuracy and performance characteristics with this point-of-care test that exceeds conventional clinical testing with external laboratory evaluation. The description, indications for use, procedural steps, and laboratory and clinical characterization of this assay are presented in this article. |
format | Online Article Text |
id | pubmed-4869842 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-48698422016-06-07 ROM Plus(®): accurate point-of-care detection of ruptured fetal membranes McQuivey, Ross W Block, Jon E Med Devices (Auckl) Review Accurate and timely diagnosis of rupture of fetal membranes is imperative to inform and guide gestational age-specific interventions to optimize perinatal outcomes and reduce the risk of serious complications, including preterm delivery and infections. The ROM Plus is a rapid, point-of-care, qualitative immunochromatographic diagnostic test that uses a unique monoclonal/polyclonal antibody approach to detect two different proteins found in amniotic fluid at high concentrations: alpha-fetoprotein and insulin-like growth factor binding protein-1. Clinical study results have uniformly demonstrated high diagnostic accuracy and performance characteristics with this point-of-care test that exceeds conventional clinical testing with external laboratory evaluation. The description, indications for use, procedural steps, and laboratory and clinical characterization of this assay are presented in this article. Dove Medical Press 2016-05-09 /pmc/articles/PMC4869842/ /pubmed/27274316 http://dx.doi.org/10.2147/MDER.S106106 Text en © 2016 McQuivey and Block. This work is published and licensed by Dove Medical Press Limited The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Review McQuivey, Ross W Block, Jon E ROM Plus(®): accurate point-of-care detection of ruptured fetal membranes |
title | ROM Plus(®): accurate point-of-care detection of ruptured fetal membranes |
title_full | ROM Plus(®): accurate point-of-care detection of ruptured fetal membranes |
title_fullStr | ROM Plus(®): accurate point-of-care detection of ruptured fetal membranes |
title_full_unstemmed | ROM Plus(®): accurate point-of-care detection of ruptured fetal membranes |
title_short | ROM Plus(®): accurate point-of-care detection of ruptured fetal membranes |
title_sort | rom plus(®): accurate point-of-care detection of ruptured fetal membranes |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4869842/ https://www.ncbi.nlm.nih.gov/pubmed/27274316 http://dx.doi.org/10.2147/MDER.S106106 |
work_keys_str_mv | AT mcquiveyrossw romplusaccuratepointofcaredetectionofrupturedfetalmembranes AT blockjone romplusaccuratepointofcaredetectionofrupturedfetalmembranes |