Cargando…
Accuracy of the Safer Dx Instrument to Identify Diagnostic Errors in Primary Care
IMPORTANCE: Diagnostic errors are common and harmful, but difficult to define and measure. Measurement of diagnostic errors often depends on retrospective medical record reviews, frequently resulting in reviewer disagreement. OBJECTIVES: We aimed to test the accuracy of an instrument to help detect...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4870415/ https://www.ncbi.nlm.nih.gov/pubmed/26902245 http://dx.doi.org/10.1007/s11606-016-3601-x |
Sumario: | IMPORTANCE: Diagnostic errors are common and harmful, but difficult to define and measure. Measurement of diagnostic errors often depends on retrospective medical record reviews, frequently resulting in reviewer disagreement. OBJECTIVES: We aimed to test the accuracy of an instrument to help detect presence or absence of diagnostic error through record reviews. DESIGN: We gathered questions from several previously used instruments for diagnostic error measurement, then developed and refined our instrument. We tested the accuracy of the instrument against a sample of patient records (n = 389), with and without previously identified diagnostic errors (n = 129 and n = 260, respectively). RESULTS: The final version of our instrument (titled Safer Dx Instrument) consisted of 11 questions assessing diagnostic processes in the patient–provider encounter and a main outcome question to determine diagnostic error. In comparison with the previous sample, the instrument yielded an overall accuracy of 84 %, sensitivity of 71 %, specificity of 90 %, negative predictive value of 86 %, and positive predictive value of 78 %. All 11 items correlated significantly with the instrument’s error outcome question (all p values ≤ 0.01). Using factor analysis, the 11 questions clustered into two domains with high internal consistency (initial diagnostic assessment, and performance and interpretation of diagnostic tests) and a patient factor domain with low internal consistency (Cronbach’s alpha coefficients 0.93, 0.92, and 0.38, respectively). CONCLUSIONS: The Safer Dx Instrument helps quantify the likelihood of diagnostic error in primary care visits, achieving a high degree of accuracy for measuring their presence or absence. This instrument could be useful to identify high-risk cases for further study and quality improvement. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s11606-016-3601-x) contains supplementary material, which is available to authorized users. |
---|