Cargando…

Prophylactic Resorbable Synthetic Mesh to Prevent Wound Dehiscence and Incisional Hernia in High High-risk Laparotomy: A Pilot Study of Using TIGR Matrix Mesh

BACKGROUND: Wound dehiscence and incisional hernia are potentially serious complications following abdominal surgery, especially if performed through a midline incision. Although prophylactic reinforcement with on-lay mesh has been shown to reduce this risk, a permanent mesh carries the risk of sero...

Descripción completa

Detalles Bibliográficos
Autores principales: Söderbäck, Harald, Mahteme, Haile, Hellman, Per, Sandblom, Gabriel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4870474/
https://www.ncbi.nlm.nih.gov/pubmed/27243017
http://dx.doi.org/10.3389/fsurg.2016.00028
_version_ 1782432438888169472
author Söderbäck, Harald
Mahteme, Haile
Hellman, Per
Sandblom, Gabriel
author_facet Söderbäck, Harald
Mahteme, Haile
Hellman, Per
Sandblom, Gabriel
author_sort Söderbäck, Harald
collection PubMed
description BACKGROUND: Wound dehiscence and incisional hernia are potentially serious complications following abdominal surgery, especially if performed through a midline incision. Although prophylactic reinforcement with on-lay mesh has been shown to reduce this risk, a permanent mesh carries the risk of seroma formation, infection, and persistent pain. The aim of this study was to assess the safety of a reabsorbable on-lay mesh to reinforce the midline suture in patients with high risk for wound dehiscence or incisional hernia. METHOD: Sixteen patients with three or more risk factors for wound dehiscence or incisional hernia were included. A TIGR(®) Matrix mesh, composed of a mixture of 40% copolymer fibers of polyglycolide, polylactide, and polytrimethylene carbonate and 60% copolymer fibers of polylactide and polytrimethylene carbonate, was placed on the aponeurosis with an overlap of five on either side and fixated with continuous monofilament polydioxanone suture. All postoperative complications were registered at clinical follow-up. RESULTS: Mean follow-up was 9 months. One patient developed a seroma that needed drainage and antibiotic treatment. One patient had a wound infection that needed antibiotic treatment. There was no complication requiring a reoperation. No wound dehiscence or incisional hernia was seen. CONCLUSION: On-lay placement of TIGR(®) Matrix is safe and may provide a feasible way of reinforcing the suture line in patients with high risk for postoperative wound dehiscence or incisional hernia. Larger samples are required, however, if one is to draw any conclusion regarding the safety and effectiveness of this technique.
format Online
Article
Text
id pubmed-4870474
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-48704742016-05-30 Prophylactic Resorbable Synthetic Mesh to Prevent Wound Dehiscence and Incisional Hernia in High High-risk Laparotomy: A Pilot Study of Using TIGR Matrix Mesh Söderbäck, Harald Mahteme, Haile Hellman, Per Sandblom, Gabriel Front Surg Surgery BACKGROUND: Wound dehiscence and incisional hernia are potentially serious complications following abdominal surgery, especially if performed through a midline incision. Although prophylactic reinforcement with on-lay mesh has been shown to reduce this risk, a permanent mesh carries the risk of seroma formation, infection, and persistent pain. The aim of this study was to assess the safety of a reabsorbable on-lay mesh to reinforce the midline suture in patients with high risk for wound dehiscence or incisional hernia. METHOD: Sixteen patients with three or more risk factors for wound dehiscence or incisional hernia were included. A TIGR(®) Matrix mesh, composed of a mixture of 40% copolymer fibers of polyglycolide, polylactide, and polytrimethylene carbonate and 60% copolymer fibers of polylactide and polytrimethylene carbonate, was placed on the aponeurosis with an overlap of five on either side and fixated with continuous monofilament polydioxanone suture. All postoperative complications were registered at clinical follow-up. RESULTS: Mean follow-up was 9 months. One patient developed a seroma that needed drainage and antibiotic treatment. One patient had a wound infection that needed antibiotic treatment. There was no complication requiring a reoperation. No wound dehiscence or incisional hernia was seen. CONCLUSION: On-lay placement of TIGR(®) Matrix is safe and may provide a feasible way of reinforcing the suture line in patients with high risk for postoperative wound dehiscence or incisional hernia. Larger samples are required, however, if one is to draw any conclusion regarding the safety and effectiveness of this technique. Frontiers Media S.A. 2016-05-18 /pmc/articles/PMC4870474/ /pubmed/27243017 http://dx.doi.org/10.3389/fsurg.2016.00028 Text en Copyright © 2016 Söderbäck, Mahteme, Hellman and Sandblom. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Surgery
Söderbäck, Harald
Mahteme, Haile
Hellman, Per
Sandblom, Gabriel
Prophylactic Resorbable Synthetic Mesh to Prevent Wound Dehiscence and Incisional Hernia in High High-risk Laparotomy: A Pilot Study of Using TIGR Matrix Mesh
title Prophylactic Resorbable Synthetic Mesh to Prevent Wound Dehiscence and Incisional Hernia in High High-risk Laparotomy: A Pilot Study of Using TIGR Matrix Mesh
title_full Prophylactic Resorbable Synthetic Mesh to Prevent Wound Dehiscence and Incisional Hernia in High High-risk Laparotomy: A Pilot Study of Using TIGR Matrix Mesh
title_fullStr Prophylactic Resorbable Synthetic Mesh to Prevent Wound Dehiscence and Incisional Hernia in High High-risk Laparotomy: A Pilot Study of Using TIGR Matrix Mesh
title_full_unstemmed Prophylactic Resorbable Synthetic Mesh to Prevent Wound Dehiscence and Incisional Hernia in High High-risk Laparotomy: A Pilot Study of Using TIGR Matrix Mesh
title_short Prophylactic Resorbable Synthetic Mesh to Prevent Wound Dehiscence and Incisional Hernia in High High-risk Laparotomy: A Pilot Study of Using TIGR Matrix Mesh
title_sort prophylactic resorbable synthetic mesh to prevent wound dehiscence and incisional hernia in high high-risk laparotomy: a pilot study of using tigr matrix mesh
topic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4870474/
https://www.ncbi.nlm.nih.gov/pubmed/27243017
http://dx.doi.org/10.3389/fsurg.2016.00028
work_keys_str_mv AT soderbackharald prophylacticresorbablesyntheticmeshtopreventwounddehiscenceandincisionalherniainhighhighrisklaparotomyapilotstudyofusingtigrmatrixmesh
AT mahtemehaile prophylacticresorbablesyntheticmeshtopreventwounddehiscenceandincisionalherniainhighhighrisklaparotomyapilotstudyofusingtigrmatrixmesh
AT hellmanper prophylacticresorbablesyntheticmeshtopreventwounddehiscenceandincisionalherniainhighhighrisklaparotomyapilotstudyofusingtigrmatrixmesh
AT sandblomgabriel prophylacticresorbablesyntheticmeshtopreventwounddehiscenceandincisionalherniainhighhighrisklaparotomyapilotstudyofusingtigrmatrixmesh