Cargando…

Development of a morphology-based modeling technique for tracking solid-body displacements: examining the reliability of a potential MRI-only approach for joint kinematics assessment

BACKGROUND: Single or biplanar video radiography and Roentgen stereophotogrammetry (RSA) techniques used for the assessment of in-vivo joint kinematics involves application of ionizing radiation, which is a limitation for clinical research involving human subjects. To overcome this limitation, our l...

Descripción completa

Detalles Bibliográficos
Autores principales: Mahato, Niladri K., Montuelle, Stephane, Cotton, John, Williams, Susan, Thomas, James, Clark, Brian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4870733/
https://www.ncbi.nlm.nih.gov/pubmed/27189195
http://dx.doi.org/10.1186/s12880-016-0140-1
_version_ 1782432485839208448
author Mahato, Niladri K.
Montuelle, Stephane
Cotton, John
Williams, Susan
Thomas, James
Clark, Brian
author_facet Mahato, Niladri K.
Montuelle, Stephane
Cotton, John
Williams, Susan
Thomas, James
Clark, Brian
author_sort Mahato, Niladri K.
collection PubMed
description BACKGROUND: Single or biplanar video radiography and Roentgen stereophotogrammetry (RSA) techniques used for the assessment of in-vivo joint kinematics involves application of ionizing radiation, which is a limitation for clinical research involving human subjects. To overcome this limitation, our long-term goal is to develop a magnetic resonance imaging (MRI)-only, three dimensional (3-D) modeling technique that permits dynamic imaging of joint motion in humans. Here, we present our initial findings, as well as reliability data, for an MRI-only protocol and modeling technique. METHODS: We developed a morphology-based motion-analysis technique that uses MRI of custom-built solid-body objects to animate and quantify experimental displacements between them. The technique involved four major steps. First, the imaging volume was calibrated using a custom-built grid. Second, 3-D models were segmented from axial scans of two custom-built solid-body cubes. Third, these cubes were positioned at pre-determined relative displacements (translation and rotation) in the magnetic resonance coil and scanned with a T(1) and a fast contrast-enhanced pulse sequences. The digital imaging and communications in medicine (DICOM) images were then processed for animation. The fourth step involved importing these processed images into an animation software, where they were displayed as background scenes. In the same step, 3-D models of the cubes were imported into the animation software, where the user manipulated the models to match their outlines in the scene (rotoscoping) and registered the models into an anatomical joint system. Measurements of displacements obtained from two different rotoscoping sessions were tested for reliability using coefficient of variations (CV), intraclass correlation coefficients (ICC), Bland-Altman plots, and Limits of Agreement analyses. RESULTS: Between-session reliability was high for both the T(1) and the contrast-enhanced sequences. Specifically, the average CVs for translation were 4.31 % and 5.26 % for the two pulse sequences, respectively, while the ICCs were 0.99 for both. For rotation measures, the CVs were 3.19 % and 2.44 % for the two pulse sequences with the ICCs being 0.98 and 0.97, respectively. A novel biplanar imaging approach also yielded high reliability with mean CVs of 2.66 % and 3.39 % for translation in the x- and z-planes, respectively, and ICCs of 0.97 in both planes. CONCLUSIONS: This work provides basic proof-of-concept for a reliable marker-less non-ionizing-radiation-based quasi-dynamic motion quantification technique that can potentially be developed into a tool for real-time joint kinematics analysis.
format Online
Article
Text
id pubmed-4870733
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-48707332016-05-19 Development of a morphology-based modeling technique for tracking solid-body displacements: examining the reliability of a potential MRI-only approach for joint kinematics assessment Mahato, Niladri K. Montuelle, Stephane Cotton, John Williams, Susan Thomas, James Clark, Brian BMC Med Imaging Research Article BACKGROUND: Single or biplanar video radiography and Roentgen stereophotogrammetry (RSA) techniques used for the assessment of in-vivo joint kinematics involves application of ionizing radiation, which is a limitation for clinical research involving human subjects. To overcome this limitation, our long-term goal is to develop a magnetic resonance imaging (MRI)-only, three dimensional (3-D) modeling technique that permits dynamic imaging of joint motion in humans. Here, we present our initial findings, as well as reliability data, for an MRI-only protocol and modeling technique. METHODS: We developed a morphology-based motion-analysis technique that uses MRI of custom-built solid-body objects to animate and quantify experimental displacements between them. The technique involved four major steps. First, the imaging volume was calibrated using a custom-built grid. Second, 3-D models were segmented from axial scans of two custom-built solid-body cubes. Third, these cubes were positioned at pre-determined relative displacements (translation and rotation) in the magnetic resonance coil and scanned with a T(1) and a fast contrast-enhanced pulse sequences. The digital imaging and communications in medicine (DICOM) images were then processed for animation. The fourth step involved importing these processed images into an animation software, where they were displayed as background scenes. In the same step, 3-D models of the cubes were imported into the animation software, where the user manipulated the models to match their outlines in the scene (rotoscoping) and registered the models into an anatomical joint system. Measurements of displacements obtained from two different rotoscoping sessions were tested for reliability using coefficient of variations (CV), intraclass correlation coefficients (ICC), Bland-Altman plots, and Limits of Agreement analyses. RESULTS: Between-session reliability was high for both the T(1) and the contrast-enhanced sequences. Specifically, the average CVs for translation were 4.31 % and 5.26 % for the two pulse sequences, respectively, while the ICCs were 0.99 for both. For rotation measures, the CVs were 3.19 % and 2.44 % for the two pulse sequences with the ICCs being 0.98 and 0.97, respectively. A novel biplanar imaging approach also yielded high reliability with mean CVs of 2.66 % and 3.39 % for translation in the x- and z-planes, respectively, and ICCs of 0.97 in both planes. CONCLUSIONS: This work provides basic proof-of-concept for a reliable marker-less non-ionizing-radiation-based quasi-dynamic motion quantification technique that can potentially be developed into a tool for real-time joint kinematics analysis. BioMed Central 2016-05-18 /pmc/articles/PMC4870733/ /pubmed/27189195 http://dx.doi.org/10.1186/s12880-016-0140-1 Text en © Mahato et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Mahato, Niladri K.
Montuelle, Stephane
Cotton, John
Williams, Susan
Thomas, James
Clark, Brian
Development of a morphology-based modeling technique for tracking solid-body displacements: examining the reliability of a potential MRI-only approach for joint kinematics assessment
title Development of a morphology-based modeling technique for tracking solid-body displacements: examining the reliability of a potential MRI-only approach for joint kinematics assessment
title_full Development of a morphology-based modeling technique for tracking solid-body displacements: examining the reliability of a potential MRI-only approach for joint kinematics assessment
title_fullStr Development of a morphology-based modeling technique for tracking solid-body displacements: examining the reliability of a potential MRI-only approach for joint kinematics assessment
title_full_unstemmed Development of a morphology-based modeling technique for tracking solid-body displacements: examining the reliability of a potential MRI-only approach for joint kinematics assessment
title_short Development of a morphology-based modeling technique for tracking solid-body displacements: examining the reliability of a potential MRI-only approach for joint kinematics assessment
title_sort development of a morphology-based modeling technique for tracking solid-body displacements: examining the reliability of a potential mri-only approach for joint kinematics assessment
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4870733/
https://www.ncbi.nlm.nih.gov/pubmed/27189195
http://dx.doi.org/10.1186/s12880-016-0140-1
work_keys_str_mv AT mahatoniladrik developmentofamorphologybasedmodelingtechniquefortrackingsolidbodydisplacementsexaminingthereliabilityofapotentialmrionlyapproachforjointkinematicsassessment
AT montuellestephane developmentofamorphologybasedmodelingtechniquefortrackingsolidbodydisplacementsexaminingthereliabilityofapotentialmrionlyapproachforjointkinematicsassessment
AT cottonjohn developmentofamorphologybasedmodelingtechniquefortrackingsolidbodydisplacementsexaminingthereliabilityofapotentialmrionlyapproachforjointkinematicsassessment
AT williamssusan developmentofamorphologybasedmodelingtechniquefortrackingsolidbodydisplacementsexaminingthereliabilityofapotentialmrionlyapproachforjointkinematicsassessment
AT thomasjames developmentofamorphologybasedmodelingtechniquefortrackingsolidbodydisplacementsexaminingthereliabilityofapotentialmrionlyapproachforjointkinematicsassessment
AT clarkbrian developmentofamorphologybasedmodelingtechniquefortrackingsolidbodydisplacementsexaminingthereliabilityofapotentialmrionlyapproachforjointkinematicsassessment