Cargando…

A Randomized Clinical Trial Comparing the Standard Mcintosh Laryngoscope and the C-Mac D blade Video laryngoscope™ for Double Lumen Tube Insertion for One Lung Ventilation in Onco surgical Patients

BACKGROUND AND AIMS: Several devices enabling double-lumen tube (DLT) placement for thoracic surgeries are available, but there are no studies for D-blade video laryngoscope-guided DLT insertion. We compared the CMac D-blade videolaryngoscope™ and the Macintosh laryngoscope for DLT endobronchial int...

Descripción completa

Detalles Bibliográficos
Autores principales: Shah, Shagun Bhatia, Bhargava, Ajay Kumar, Hariharan, Uma, Mittal, Amit Kumar, Goel, Nitesh, Choudhary, Manish
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4870943/
https://www.ncbi.nlm.nih.gov/pubmed/27212717
http://dx.doi.org/10.4103/0019-5049.181591
_version_ 1782432523564875776
author Shah, Shagun Bhatia
Bhargava, Ajay Kumar
Hariharan, Uma
Mittal, Amit Kumar
Goel, Nitesh
Choudhary, Manish
author_facet Shah, Shagun Bhatia
Bhargava, Ajay Kumar
Hariharan, Uma
Mittal, Amit Kumar
Goel, Nitesh
Choudhary, Manish
author_sort Shah, Shagun Bhatia
collection PubMed
description BACKGROUND AND AIMS: Several devices enabling double-lumen tube (DLT) placement for thoracic surgeries are available, but there are no studies for D-blade video laryngoscope-guided DLT insertion. We compared the CMac D-blade videolaryngoscope™ and the Macintosh laryngoscope for DLT endobronchial intubation using parameters of time and attempts required for intubation, glottic view, incidence of complications and haemodynamic changes. METHODS: Prospective, parallel group, randomised controlled clinical trial where sixty American Society of Anesthesiologists I and II patients aged 18-80 years scheduled for thoracic surgeries entailing DLT placement were randomly allocated in two groups based on the laryngoscopic device used for endobronchial intubation. Data were subjected to statistical analysis SPSS (version 17), the paired and Student's t-test for equality of means. Nominal categorical data between the groups were compared using Chi-squared test or Fisher's exact test as appropriate. P ˂ 0.05 was considered statistically significant. RESULTS: Time required for intubation was comparable (37.41 ± 18.80 s in Group-M and 32.27 ± 11.13 s in Group-D). Number of attempts and incidence of complications (trauma, DLT cuff rupture, oesophageal intubation) was greater in the Macintosh group, except malpositioning into the wrong bronchus (easily rectified fibre-optic bronchoscopically), which was greater with the D-blade. Greater haemodynamic changes were observed during Macintosh laryngoscopy. CONCLUSION: D-blade videolaryngoscope™ is a useful alternative to the standard Macintosh laryngoscope for routine DLT insertion.
format Online
Article
Text
id pubmed-4870943
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-48709432016-05-20 A Randomized Clinical Trial Comparing the Standard Mcintosh Laryngoscope and the C-Mac D blade Video laryngoscope™ for Double Lumen Tube Insertion for One Lung Ventilation in Onco surgical Patients Shah, Shagun Bhatia Bhargava, Ajay Kumar Hariharan, Uma Mittal, Amit Kumar Goel, Nitesh Choudhary, Manish Indian J Anaesth Original Article BACKGROUND AND AIMS: Several devices enabling double-lumen tube (DLT) placement for thoracic surgeries are available, but there are no studies for D-blade video laryngoscope-guided DLT insertion. We compared the CMac D-blade videolaryngoscope™ and the Macintosh laryngoscope for DLT endobronchial intubation using parameters of time and attempts required for intubation, glottic view, incidence of complications and haemodynamic changes. METHODS: Prospective, parallel group, randomised controlled clinical trial where sixty American Society of Anesthesiologists I and II patients aged 18-80 years scheduled for thoracic surgeries entailing DLT placement were randomly allocated in two groups based on the laryngoscopic device used for endobronchial intubation. Data were subjected to statistical analysis SPSS (version 17), the paired and Student's t-test for equality of means. Nominal categorical data between the groups were compared using Chi-squared test or Fisher's exact test as appropriate. P ˂ 0.05 was considered statistically significant. RESULTS: Time required for intubation was comparable (37.41 ± 18.80 s in Group-M and 32.27 ± 11.13 s in Group-D). Number of attempts and incidence of complications (trauma, DLT cuff rupture, oesophageal intubation) was greater in the Macintosh group, except malpositioning into the wrong bronchus (easily rectified fibre-optic bronchoscopically), which was greater with the D-blade. Greater haemodynamic changes were observed during Macintosh laryngoscopy. CONCLUSION: D-blade videolaryngoscope™ is a useful alternative to the standard Macintosh laryngoscope for routine DLT insertion. Medknow Publications & Media Pvt Ltd 2016-05 /pmc/articles/PMC4870943/ /pubmed/27212717 http://dx.doi.org/10.4103/0019-5049.181591 Text en Copyright: © Indian Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution NonCommercial ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Shah, Shagun Bhatia
Bhargava, Ajay Kumar
Hariharan, Uma
Mittal, Amit Kumar
Goel, Nitesh
Choudhary, Manish
A Randomized Clinical Trial Comparing the Standard Mcintosh Laryngoscope and the C-Mac D blade Video laryngoscope™ for Double Lumen Tube Insertion for One Lung Ventilation in Onco surgical Patients
title A Randomized Clinical Trial Comparing the Standard Mcintosh Laryngoscope and the C-Mac D blade Video laryngoscope™ for Double Lumen Tube Insertion for One Lung Ventilation in Onco surgical Patients
title_full A Randomized Clinical Trial Comparing the Standard Mcintosh Laryngoscope and the C-Mac D blade Video laryngoscope™ for Double Lumen Tube Insertion for One Lung Ventilation in Onco surgical Patients
title_fullStr A Randomized Clinical Trial Comparing the Standard Mcintosh Laryngoscope and the C-Mac D blade Video laryngoscope™ for Double Lumen Tube Insertion for One Lung Ventilation in Onco surgical Patients
title_full_unstemmed A Randomized Clinical Trial Comparing the Standard Mcintosh Laryngoscope and the C-Mac D blade Video laryngoscope™ for Double Lumen Tube Insertion for One Lung Ventilation in Onco surgical Patients
title_short A Randomized Clinical Trial Comparing the Standard Mcintosh Laryngoscope and the C-Mac D blade Video laryngoscope™ for Double Lumen Tube Insertion for One Lung Ventilation in Onco surgical Patients
title_sort randomized clinical trial comparing the standard mcintosh laryngoscope and the c-mac d blade video laryngoscope™ for double lumen tube insertion for one lung ventilation in onco surgical patients
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4870943/
https://www.ncbi.nlm.nih.gov/pubmed/27212717
http://dx.doi.org/10.4103/0019-5049.181591
work_keys_str_mv AT shahshagunbhatia arandomizedclinicaltrialcomparingthestandardmcintoshlaryngoscopeandthecmacdbladevideolaryngoscopefordoublelumentubeinsertionforonelungventilationinoncosurgicalpatients
AT bhargavaajaykumar arandomizedclinicaltrialcomparingthestandardmcintoshlaryngoscopeandthecmacdbladevideolaryngoscopefordoublelumentubeinsertionforonelungventilationinoncosurgicalpatients
AT hariharanuma arandomizedclinicaltrialcomparingthestandardmcintoshlaryngoscopeandthecmacdbladevideolaryngoscopefordoublelumentubeinsertionforonelungventilationinoncosurgicalpatients
AT mittalamitkumar arandomizedclinicaltrialcomparingthestandardmcintoshlaryngoscopeandthecmacdbladevideolaryngoscopefordoublelumentubeinsertionforonelungventilationinoncosurgicalpatients
AT goelnitesh arandomizedclinicaltrialcomparingthestandardmcintoshlaryngoscopeandthecmacdbladevideolaryngoscopefordoublelumentubeinsertionforonelungventilationinoncosurgicalpatients
AT choudharymanish arandomizedclinicaltrialcomparingthestandardmcintoshlaryngoscopeandthecmacdbladevideolaryngoscopefordoublelumentubeinsertionforonelungventilationinoncosurgicalpatients
AT shahshagunbhatia randomizedclinicaltrialcomparingthestandardmcintoshlaryngoscopeandthecmacdbladevideolaryngoscopefordoublelumentubeinsertionforonelungventilationinoncosurgicalpatients
AT bhargavaajaykumar randomizedclinicaltrialcomparingthestandardmcintoshlaryngoscopeandthecmacdbladevideolaryngoscopefordoublelumentubeinsertionforonelungventilationinoncosurgicalpatients
AT hariharanuma randomizedclinicaltrialcomparingthestandardmcintoshlaryngoscopeandthecmacdbladevideolaryngoscopefordoublelumentubeinsertionforonelungventilationinoncosurgicalpatients
AT mittalamitkumar randomizedclinicaltrialcomparingthestandardmcintoshlaryngoscopeandthecmacdbladevideolaryngoscopefordoublelumentubeinsertionforonelungventilationinoncosurgicalpatients
AT goelnitesh randomizedclinicaltrialcomparingthestandardmcintoshlaryngoscopeandthecmacdbladevideolaryngoscopefordoublelumentubeinsertionforonelungventilationinoncosurgicalpatients
AT choudharymanish randomizedclinicaltrialcomparingthestandardmcintoshlaryngoscopeandthecmacdbladevideolaryngoscopefordoublelumentubeinsertionforonelungventilationinoncosurgicalpatients