Cargando…

Build-up material requirements in clinical dosimetry during total body irradiation treatments

Total body irradiation (TBI) treatments are mainly used in a preparative regimen for hematopoietic stem cell (or bone marrow) transplantation. Our standard clinical regimen is a 12 Gy/6 fraction bi-daily technique using 6MV X-rays at a large extended source to surface distance (SSD). This work inves...

Descripción completa

Detalles Bibliográficos
Autores principales: Butson, Martin, Pope, Dane, Haque, Mamoon, Chen, Tom, Song, Guangli, Whitaker, May
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4871005/
https://www.ncbi.nlm.nih.gov/pubmed/27217628
http://dx.doi.org/10.4103/0971-6203.181632
_version_ 1782432537637814272
author Butson, Martin
Pope, Dane
Haque, Mamoon
Chen, Tom
Song, Guangli
Whitaker, May
author_facet Butson, Martin
Pope, Dane
Haque, Mamoon
Chen, Tom
Song, Guangli
Whitaker, May
author_sort Butson, Martin
collection PubMed
description Total body irradiation (TBI) treatments are mainly used in a preparative regimen for hematopoietic stem cell (or bone marrow) transplantation. Our standard clinical regimen is a 12 Gy/6 fraction bi-daily technique using 6MV X-rays at a large extended source to surface distance (SSD). This work investigates and quantifies the dose build-up characteristics and thus the requirements for bolus used for in vivo dosimetry for TBI applications. Percentage dose build-up characteristics of photon beams have been investigated at large extended SSDs using ionization chambers and Gafchromic film. Open field measurements at different field sizes and with differing scatter conditions such as the introduction of standard Perspex scattering plates at different distances to the measurement point were made in an effort to determine the required bolus/build-up material required for accurate determination of applied dose. Percentage surface dose values measured for open fields at 300 cm SSD were found to range from 20% up to 65.5% for fields 5 cm × 5 cm to 40 cm × 40 cm, respectively. With the introduction of 1 cm Perspex scattering plates used in TBI treatments, the surface dose values increased up to 83–90% (93–97% at 1 mm depth), depending on the position of the Perspex scattering plate compared to the measurement point. Our work showed that at least 5 mm water equivalent bolus/scatter material should be placed over the EBT3 film for accurate dose assessment for TBI treatments. Results also show that a small but measurable decrease in measured dose occurred with 5 mm water equivalent thick bolus material of areas '3 cm(2). As such, we recommend that 3 cm × 3 cm × 5 mm bolus build-up is the smallest size that should be placed over EBT3 Gafchromic film when used for accurate in vivo dosimetry for TBI applications.
format Online
Article
Text
id pubmed-4871005
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-48710052016-05-23 Build-up material requirements in clinical dosimetry during total body irradiation treatments Butson, Martin Pope, Dane Haque, Mamoon Chen, Tom Song, Guangli Whitaker, May J Med Phys Original Article Total body irradiation (TBI) treatments are mainly used in a preparative regimen for hematopoietic stem cell (or bone marrow) transplantation. Our standard clinical regimen is a 12 Gy/6 fraction bi-daily technique using 6MV X-rays at a large extended source to surface distance (SSD). This work investigates and quantifies the dose build-up characteristics and thus the requirements for bolus used for in vivo dosimetry for TBI applications. Percentage dose build-up characteristics of photon beams have been investigated at large extended SSDs using ionization chambers and Gafchromic film. Open field measurements at different field sizes and with differing scatter conditions such as the introduction of standard Perspex scattering plates at different distances to the measurement point were made in an effort to determine the required bolus/build-up material required for accurate determination of applied dose. Percentage surface dose values measured for open fields at 300 cm SSD were found to range from 20% up to 65.5% for fields 5 cm × 5 cm to 40 cm × 40 cm, respectively. With the introduction of 1 cm Perspex scattering plates used in TBI treatments, the surface dose values increased up to 83–90% (93–97% at 1 mm depth), depending on the position of the Perspex scattering plate compared to the measurement point. Our work showed that at least 5 mm water equivalent bolus/scatter material should be placed over the EBT3 film for accurate dose assessment for TBI treatments. Results also show that a small but measurable decrease in measured dose occurred with 5 mm water equivalent thick bolus material of areas '3 cm(2). As such, we recommend that 3 cm × 3 cm × 5 mm bolus build-up is the smallest size that should be placed over EBT3 Gafchromic film when used for accurate in vivo dosimetry for TBI applications. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC4871005/ /pubmed/27217628 http://dx.doi.org/10.4103/0971-6203.181632 Text en Copyright: © Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution NonCommercial ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Butson, Martin
Pope, Dane
Haque, Mamoon
Chen, Tom
Song, Guangli
Whitaker, May
Build-up material requirements in clinical dosimetry during total body irradiation treatments
title Build-up material requirements in clinical dosimetry during total body irradiation treatments
title_full Build-up material requirements in clinical dosimetry during total body irradiation treatments
title_fullStr Build-up material requirements in clinical dosimetry during total body irradiation treatments
title_full_unstemmed Build-up material requirements in clinical dosimetry during total body irradiation treatments
title_short Build-up material requirements in clinical dosimetry during total body irradiation treatments
title_sort build-up material requirements in clinical dosimetry during total body irradiation treatments
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4871005/
https://www.ncbi.nlm.nih.gov/pubmed/27217628
http://dx.doi.org/10.4103/0971-6203.181632
work_keys_str_mv AT butsonmartin buildupmaterialrequirementsinclinicaldosimetryduringtotalbodyirradiationtreatments
AT popedane buildupmaterialrequirementsinclinicaldosimetryduringtotalbodyirradiationtreatments
AT haquemamoon buildupmaterialrequirementsinclinicaldosimetryduringtotalbodyirradiationtreatments
AT chentom buildupmaterialrequirementsinclinicaldosimetryduringtotalbodyirradiationtreatments
AT songguangli buildupmaterialrequirementsinclinicaldosimetryduringtotalbodyirradiationtreatments
AT whitakermay buildupmaterialrequirementsinclinicaldosimetryduringtotalbodyirradiationtreatments