Cargando…
Initial experience with sacral neuromodulation for the treatment of lower urinary tract dysfunction in Brazil
OBJECTIVES: We report on the short-term outcomes of sacral neuromodulation (SNM) for treatment of idiopathic lower urinary tract dysfunction in Brazil (procedures performed before 2014). MATERIALS AND METHODS: Clinical data and surgical outcomes of patients who underwent SNM staged procedures were r...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sociedade Brasileira de Urologia
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4871392/ https://www.ncbi.nlm.nih.gov/pubmed/27176186 http://dx.doi.org/10.1590/S1677-5538.IBJU.2014.0603 |
Sumario: | OBJECTIVES: We report on the short-term outcomes of sacral neuromodulation (SNM) for treatment of idiopathic lower urinary tract dysfunction in Brazil (procedures performed before 2014). MATERIALS AND METHODS: Clinical data and surgical outcomes of patients who underwent SNM staged procedures were retrospective evaluated. Urological assessment included a focused medical history and physical examination, measurement of postvoid residual volumes, urodynamics, and bladder diaries. A successful test phase has been defined by improvement of at least 50% of the symptoms, based on bladder diaries. RESULTS: From January 2011 to December 2013, eighteen consecutive patients underwent test phase for SNM due to refractory overactive bladder (15 patients), non-obstructive chronic urinary retention (2 patients), and bladder pain syndrome/interstitial cystitis (1 patient). All patients underwent staged procedures at four outpatient surgical centers. Mean age was 48.3±21.2 (range 10-84 years). There were 16 women and 2 men. Median follow-up was 3 months. Fifteen patients (83.3%) had a successful test phase and underwent implantation of the pulse generator (IPG). Median duration of the test phase was 7 days (range 5–24 days). Mean age was 45.6±18.19 years in responders versus 61.66±34.44 years in non-responders (p=0.242). Mean operative time (test phase) was 99±33.12 min in responders versus 95±35 min for non-responders (p=0.852). No severe complications were reported. CONCLUSION: SNM is a minimally invasive treatment option for patients with refractory idiopathic lower urinary tract dysfunction. Our initial experience with staged technique showed that tined-lead electrodes yielded a high rate of responders and favorable clinical results in the short-term follow-up. |
---|