A Comprehensive Evaluation of NIPAM Polymer Gel Dosimeters on Three Orthogonal Planes and Temporal Stability Analysis

Polymer gel dosimeters have been proven useful for dose evaluation in radiotherapy treatments. Previous studies have demonstrated that using a polymer gel dosimeter requires a 24 h reaction time to stabilize and further evaluate the measured dose distribution in two-dimensional dosimetry. In this st...

Descripción completa

Detalles Bibliográficos
Autores principales: Cheng, Kai-Yuan, Hsieh, Ling-Ling, Shih, Cheng-Ting
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4871428/
https://www.ncbi.nlm.nih.gov/pubmed/27192217
http://dx.doi.org/10.1371/journal.pone.0155797
_version_ 1782432589101924352
author Cheng, Kai-Yuan
Hsieh, Ling-Ling
Shih, Cheng-Ting
author_facet Cheng, Kai-Yuan
Hsieh, Ling-Ling
Shih, Cheng-Ting
author_sort Cheng, Kai-Yuan
collection PubMed
description Polymer gel dosimeters have been proven useful for dose evaluation in radiotherapy treatments. Previous studies have demonstrated that using a polymer gel dosimeter requires a 24 h reaction time to stabilize and further evaluate the measured dose distribution in two-dimensional dosimetry. In this study, the short-term stability within 24 h and feasibility of N-isopropylacrylamide (NIPAM) polymer gel dosimeters for use in three-dimensional dosimetry were evaluated using magnetic resonance imaging (MRI). NIPAM gels were used to measure the dose volume in a clinical case of intensity-modulated radiation therapy (IMRT). For dose readouts, MR images of irradiated NIPAM gel phantoms were acquired at 2, 5, 12, and 24 h after dose delivery. The mean standard errors of dose conversion from using dose calibration curves (DRC) were calculated. The measured dose volumes at the four time points were compared with those calculated using a treatment planning system (TPS). The mean standard errors of the dose conversion from using the DRCs were lower than 1 Gy. Mean pass rates of 2, 5, 12, and 24 h axial dose maps calculated using gamma evaluation with 3% dose difference and 3 mm distance-to-agreement criteria were 83.5% ± 0.9%, 85.9% ± 0.6%, 98.7% ± 0.3%, and 98.5% ± 0.9%, respectively. Compared with the dose volume histogram of the TPS, the absolute mean relative volume differences of the 2, 5, 12, and 24 h measured dose volumes were lower than 1% for the irradiated region with an absorbed dose higher than 2.8 Gy. It was concluded that a 12 h reaction time was sufficient to acquire accurate dose volume using the NIPAM gels with MR readouts.
format Online
Article
Text
id pubmed-4871428
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-48714282016-05-31 A Comprehensive Evaluation of NIPAM Polymer Gel Dosimeters on Three Orthogonal Planes and Temporal Stability Analysis Cheng, Kai-Yuan Hsieh, Ling-Ling Shih, Cheng-Ting PLoS One Research Article Polymer gel dosimeters have been proven useful for dose evaluation in radiotherapy treatments. Previous studies have demonstrated that using a polymer gel dosimeter requires a 24 h reaction time to stabilize and further evaluate the measured dose distribution in two-dimensional dosimetry. In this study, the short-term stability within 24 h and feasibility of N-isopropylacrylamide (NIPAM) polymer gel dosimeters for use in three-dimensional dosimetry were evaluated using magnetic resonance imaging (MRI). NIPAM gels were used to measure the dose volume in a clinical case of intensity-modulated radiation therapy (IMRT). For dose readouts, MR images of irradiated NIPAM gel phantoms were acquired at 2, 5, 12, and 24 h after dose delivery. The mean standard errors of dose conversion from using dose calibration curves (DRC) were calculated. The measured dose volumes at the four time points were compared with those calculated using a treatment planning system (TPS). The mean standard errors of the dose conversion from using the DRCs were lower than 1 Gy. Mean pass rates of 2, 5, 12, and 24 h axial dose maps calculated using gamma evaluation with 3% dose difference and 3 mm distance-to-agreement criteria were 83.5% ± 0.9%, 85.9% ± 0.6%, 98.7% ± 0.3%, and 98.5% ± 0.9%, respectively. Compared with the dose volume histogram of the TPS, the absolute mean relative volume differences of the 2, 5, 12, and 24 h measured dose volumes were lower than 1% for the irradiated region with an absorbed dose higher than 2.8 Gy. It was concluded that a 12 h reaction time was sufficient to acquire accurate dose volume using the NIPAM gels with MR readouts. Public Library of Science 2016-05-18 /pmc/articles/PMC4871428/ /pubmed/27192217 http://dx.doi.org/10.1371/journal.pone.0155797 Text en © 2016 Cheng et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Cheng, Kai-Yuan
Hsieh, Ling-Ling
Shih, Cheng-Ting
A Comprehensive Evaluation of NIPAM Polymer Gel Dosimeters on Three Orthogonal Planes and Temporal Stability Analysis
title A Comprehensive Evaluation of NIPAM Polymer Gel Dosimeters on Three Orthogonal Planes and Temporal Stability Analysis
title_full A Comprehensive Evaluation of NIPAM Polymer Gel Dosimeters on Three Orthogonal Planes and Temporal Stability Analysis
title_fullStr A Comprehensive Evaluation of NIPAM Polymer Gel Dosimeters on Three Orthogonal Planes and Temporal Stability Analysis
title_full_unstemmed A Comprehensive Evaluation of NIPAM Polymer Gel Dosimeters on Three Orthogonal Planes and Temporal Stability Analysis
title_short A Comprehensive Evaluation of NIPAM Polymer Gel Dosimeters on Three Orthogonal Planes and Temporal Stability Analysis
title_sort comprehensive evaluation of nipam polymer gel dosimeters on three orthogonal planes and temporal stability analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4871428/
https://www.ncbi.nlm.nih.gov/pubmed/27192217
http://dx.doi.org/10.1371/journal.pone.0155797
work_keys_str_mv AT chengkaiyuan acomprehensiveevaluationofnipampolymergeldosimetersonthreeorthogonalplanesandtemporalstabilityanalysis
AT hsiehlingling acomprehensiveevaluationofnipampolymergeldosimetersonthreeorthogonalplanesandtemporalstabilityanalysis
AT shihchengting acomprehensiveevaluationofnipampolymergeldosimetersonthreeorthogonalplanesandtemporalstabilityanalysis
AT chengkaiyuan comprehensiveevaluationofnipampolymergeldosimetersonthreeorthogonalplanesandtemporalstabilityanalysis
AT hsiehlingling comprehensiveevaluationofnipampolymergeldosimetersonthreeorthogonalplanesandtemporalstabilityanalysis
AT shihchengting comprehensiveevaluationofnipampolymergeldosimetersonthreeorthogonalplanesandtemporalstabilityanalysis