BACKGROUND: During the downstream process of bio-based bulk chemicals, organic impurities, mostly residues from the fermentation process, must be separated to obtain a pure and ready-to-market chemical. In this study, capillary electrophoresis was investigated for the non-targeting downstream proces...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4872333/ https://www.ncbi.nlm.nih.gov/pubmed/27200108 http://dx.doi.org/10.1186/s13036-016-0027-2 |
_version_ | 1782432708689920000 |
---|---|
author | Laube, Hendrik Matysik, Frank-Michael Schmidberger, Andreas Mehlmann, Kerstin Toursel, Andreas Boden, Jana |
author_facet | Laube, Hendrik Matysik, Frank-Michael Schmidberger, Andreas Mehlmann, Kerstin Toursel, Andreas Boden, Jana |
author_sort | Laube, Hendrik |
collection | PubMed |
description | BACKGROUND: During the downstream process of bio-based bulk chemicals, organic impurities, mostly residues from the fermentation process, must be separated to obtain a pure and ready-to-market chemical. In this study, capillary electrophoresis was investigated for the non-targeting downstream process monitoring of organic impurities and simultaneous quantitative detection of lactic acid during the purification process of fermentatively produced lactic acid. The downstream process incorporated 11 separation units, ranging from filtration, adsorption and ion exchange to electrodialysis and distillation, and 15 different second-generation renewable feedstocks were processed into lactic acid. The identification of organic impurities was established through spiking and the utilization of an advanced capillary electrophoresis mass spectrometry system. RESULTS: A total of 53 % of the organic impurities were efficiently removed via bipolar electrodialysis; however, one impurity, pyroglutamic acid, was recalcitrant to separation. It was demonstrated that the presence of pyroglutamic acid disrupts the polymerization of lactic acid into poly lactic acid. Pyroglutamic acid was present in all lactic acid solutions, independent of the type of renewable resource or the bacterium applied. Pyroglutamic acid, also known as 5-oxoproline, is a metabolite in the glutathione cycle, which is present in all living microorganisms. pyroglutamic acid is found in many proteins, and during intracellular protein metabolism, N-terminal glutamic acid and glutamine residues can spontaneously cyclize to become pyroglutamic acid. Hence, the concentration of pyroglutamic acid in the lactic acid solution can only be limited to a certain amount. CONCLUSIONS: The present study proved the capillary electrophoresis system to be an important tool for downstream process monitoring. The high product concentration encountered in biological production processes did not hinder the capillary electrophoresis from separating and detecting organic impurities, even at minor concentrations. The coupling of the capillary electrophoresis with a mass spectrometry system allowed for the straightforward identification of the remaining critical impurity, pyroglutamic acid. Although 11 separation units were applied during the downstream process, the pyroglutamic acid concentration remained at 12,900 ppm, which was comparatively high. All organic impurities found were tracked by the capillary electrophoresis, allowing for further separation optimization. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13036-016-0027-2) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-4872333 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-48723332016-05-20 CE-UV/VIS and CE-MS for monitoring organic impurities during the downstream processing of fermentative-produced lactic acid from second-generation renewable feedstocks Laube, Hendrik Matysik, Frank-Michael Schmidberger, Andreas Mehlmann, Kerstin Toursel, Andreas Boden, Jana J Biol Eng Research BACKGROUND: During the downstream process of bio-based bulk chemicals, organic impurities, mostly residues from the fermentation process, must be separated to obtain a pure and ready-to-market chemical. In this study, capillary electrophoresis was investigated for the non-targeting downstream process monitoring of organic impurities and simultaneous quantitative detection of lactic acid during the purification process of fermentatively produced lactic acid. The downstream process incorporated 11 separation units, ranging from filtration, adsorption and ion exchange to electrodialysis and distillation, and 15 different second-generation renewable feedstocks were processed into lactic acid. The identification of organic impurities was established through spiking and the utilization of an advanced capillary electrophoresis mass spectrometry system. RESULTS: A total of 53 % of the organic impurities were efficiently removed via bipolar electrodialysis; however, one impurity, pyroglutamic acid, was recalcitrant to separation. It was demonstrated that the presence of pyroglutamic acid disrupts the polymerization of lactic acid into poly lactic acid. Pyroglutamic acid was present in all lactic acid solutions, independent of the type of renewable resource or the bacterium applied. Pyroglutamic acid, also known as 5-oxoproline, is a metabolite in the glutathione cycle, which is present in all living microorganisms. pyroglutamic acid is found in many proteins, and during intracellular protein metabolism, N-terminal glutamic acid and glutamine residues can spontaneously cyclize to become pyroglutamic acid. Hence, the concentration of pyroglutamic acid in the lactic acid solution can only be limited to a certain amount. CONCLUSIONS: The present study proved the capillary electrophoresis system to be an important tool for downstream process monitoring. The high product concentration encountered in biological production processes did not hinder the capillary electrophoresis from separating and detecting organic impurities, even at minor concentrations. The coupling of the capillary electrophoresis with a mass spectrometry system allowed for the straightforward identification of the remaining critical impurity, pyroglutamic acid. Although 11 separation units were applied during the downstream process, the pyroglutamic acid concentration remained at 12,900 ppm, which was comparatively high. All organic impurities found were tracked by the capillary electrophoresis, allowing for further separation optimization. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13036-016-0027-2) contains supplementary material, which is available to authorized users. BioMed Central 2016-05-19 /pmc/articles/PMC4872333/ /pubmed/27200108 http://dx.doi.org/10.1186/s13036-016-0027-2 Text en © Laube et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Laube, Hendrik Matysik, Frank-Michael Schmidberger, Andreas Mehlmann, Kerstin Toursel, Andreas Boden, Jana CE-UV/VIS and CE-MS for monitoring organic impurities during the downstream processing of fermentative-produced lactic acid from second-generation renewable feedstocks |
title | CE-UV/VIS and CE-MS for monitoring organic impurities during the downstream processing of fermentative-produced lactic acid from second-generation renewable feedstocks |
title_full | CE-UV/VIS and CE-MS for monitoring organic impurities during the downstream processing of fermentative-produced lactic acid from second-generation renewable feedstocks |
title_fullStr | CE-UV/VIS and CE-MS for monitoring organic impurities during the downstream processing of fermentative-produced lactic acid from second-generation renewable feedstocks |
title_full_unstemmed | CE-UV/VIS and CE-MS for monitoring organic impurities during the downstream processing of fermentative-produced lactic acid from second-generation renewable feedstocks |
title_short | CE-UV/VIS and CE-MS for monitoring organic impurities during the downstream processing of fermentative-produced lactic acid from second-generation renewable feedstocks |
title_sort | ce-uv/vis and ce-ms for monitoring organic impurities during the downstream processing of fermentative-produced lactic acid from second-generation renewable feedstocks |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4872333/ https://www.ncbi.nlm.nih.gov/pubmed/27200108 http://dx.doi.org/10.1186/s13036-016-0027-2 |
work_keys_str_mv | AT laubehendrik ceuvvisandcemsformonitoringorganicimpuritiesduringthedownstreamprocessingoffermentativeproducedlacticacidfromsecondgenerationrenewablefeedstocks AT matysikfrankmichael ceuvvisandcemsformonitoringorganicimpuritiesduringthedownstreamprocessingoffermentativeproducedlacticacidfromsecondgenerationrenewablefeedstocks AT schmidbergerandreas ceuvvisandcemsformonitoringorganicimpuritiesduringthedownstreamprocessingoffermentativeproducedlacticacidfromsecondgenerationrenewablefeedstocks AT mehlmannkerstin ceuvvisandcemsformonitoringorganicimpuritiesduringthedownstreamprocessingoffermentativeproducedlacticacidfromsecondgenerationrenewablefeedstocks AT tourselandreas ceuvvisandcemsformonitoringorganicimpuritiesduringthedownstreamprocessingoffermentativeproducedlacticacidfromsecondgenerationrenewablefeedstocks AT bodenjana ceuvvisandcemsformonitoringorganicimpuritiesduringthedownstreamprocessingoffermentativeproducedlacticacidfromsecondgenerationrenewablefeedstocks |