Cargando…

Radiative Calibration of Heat-Flux Sensors at NIST: Facilities and Techniques

We present an overview of the National Institute of Standards and Technology high temperature blackbodies, both in operation and in development, suitable for heat-flux sensor calibration. Typical results of calibrations using the transfer technique in the 25 mm Variable-Temperature Blackbody are pre...

Descripción completa

Detalles Bibliográficos
Autores principales: Murthy, A. V., Tsai, B. K., Saunders, R. D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2000
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4872686/
https://www.ncbi.nlm.nih.gov/pubmed/27551612
http://dx.doi.org/10.6028/jres.105.033
_version_ 1782432768143130624
author Murthy, A. V.
Tsai, B. K.
Saunders, R. D.
author_facet Murthy, A. V.
Tsai, B. K.
Saunders, R. D.
author_sort Murthy, A. V.
collection PubMed
description We present an overview of the National Institute of Standards and Technology high temperature blackbodies, both in operation and in development, suitable for heat-flux sensor calibration. Typical results of calibrations using the transfer technique in the 25 mm Variable-Temperature Blackbody are presented to demonstrate the long-term repeatability of the calibration technique. A comparative study of the absolute and transfer calibrations of a Gardon gage in a spherical blackbody with a cooled enclosure surrounding the gage housing was conducted. Results of this study demonstrated the influence of convection associated with absolute calibration of sensors in a cooled enclosure. Plans for further development of the transfer technique to higher heat-flux levels and the associated technical issues are discussed.
format Online
Article
Text
id pubmed-4872686
institution National Center for Biotechnology Information
language English
publishDate 2000
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-48726862016-08-22 Radiative Calibration of Heat-Flux Sensors at NIST: Facilities and Techniques Murthy, A. V. Tsai, B. K. Saunders, R. D. J Res Natl Inst Stand Technol Article We present an overview of the National Institute of Standards and Technology high temperature blackbodies, both in operation and in development, suitable for heat-flux sensor calibration. Typical results of calibrations using the transfer technique in the 25 mm Variable-Temperature Blackbody are presented to demonstrate the long-term repeatability of the calibration technique. A comparative study of the absolute and transfer calibrations of a Gardon gage in a spherical blackbody with a cooled enclosure surrounding the gage housing was conducted. Results of this study demonstrated the influence of convection associated with absolute calibration of sensors in a cooled enclosure. Plans for further development of the transfer technique to higher heat-flux levels and the associated technical issues are discussed. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2000 2000-04-01 /pmc/articles/PMC4872686/ /pubmed/27551612 http://dx.doi.org/10.6028/jres.105.033 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Murthy, A. V.
Tsai, B. K.
Saunders, R. D.
Radiative Calibration of Heat-Flux Sensors at NIST: Facilities and Techniques
title Radiative Calibration of Heat-Flux Sensors at NIST: Facilities and Techniques
title_full Radiative Calibration of Heat-Flux Sensors at NIST: Facilities and Techniques
title_fullStr Radiative Calibration of Heat-Flux Sensors at NIST: Facilities and Techniques
title_full_unstemmed Radiative Calibration of Heat-Flux Sensors at NIST: Facilities and Techniques
title_short Radiative Calibration of Heat-Flux Sensors at NIST: Facilities and Techniques
title_sort radiative calibration of heat-flux sensors at nist: facilities and techniques
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4872686/
https://www.ncbi.nlm.nih.gov/pubmed/27551612
http://dx.doi.org/10.6028/jres.105.033
work_keys_str_mv AT murthyav radiativecalibrationofheatfluxsensorsatnistfacilitiesandtechniques
AT tsaibk radiativecalibrationofheatfluxsensorsatnistfacilitiesandtechniques
AT saundersrd radiativecalibrationofheatfluxsensorsatnistfacilitiesandtechniques