Cargando…

Standardized Loads Acting in Hip Implants

With the increasing success of hip joint replacements, the average age of patients has decreased, patients have become more active and their expectations of the implant durability have risen. Thus, pre-clinical endurance tests on hip implants require defining realistic in vivo loads from younger and...

Descripción completa

Detalles Bibliográficos
Autores principales: Bergmann, Georg, Bender, Alwina, Dymke, Jörn, Duda, Georg, Damm, Philipp
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4873223/
https://www.ncbi.nlm.nih.gov/pubmed/27195789
http://dx.doi.org/10.1371/journal.pone.0155612
_version_ 1782432866231123968
author Bergmann, Georg
Bender, Alwina
Dymke, Jörn
Duda, Georg
Damm, Philipp
author_facet Bergmann, Georg
Bender, Alwina
Dymke, Jörn
Duda, Georg
Damm, Philipp
author_sort Bergmann, Georg
collection PubMed
description With the increasing success of hip joint replacements, the average age of patients has decreased, patients have become more active and their expectations of the implant durability have risen. Thus, pre-clinical endurance tests on hip implants require defining realistic in vivo loads from younger and more active patients. These loads require simplifications to be applicable for simulator tests and numerical analyses. Here, the contact forces in the joint were measured with instrumented hip implants in ten subjects during nine of the most physically demanding and frequent activities of daily living. Typical levels and directions of average and high joint loads were extracted from the intra- and inter-individually widely varying individual data. These data can also be used to analyse bone remodelling at the implant-bone interface, evaluate tissue straining in finite element studies or validate analytical loading predictions, among other uses. The current ISO standards for endurance tests of implant stems and necks are based on historic analytical data from the 1970s. Comparisons of these test forces with in vivo loads unveiled that their unidirectional orientations deviate from the time-dependent in vivo directions during walking and most other activities. The ISO force for testing the stem is substantially too low while the ISO force for the neck better matches typical in vivo magnitudes. Because the magnitudes and orientations of peak forces substantially vary among the activities, load scenarios that reflect a collection of time-dependent high forces should be applied rather than using unidirectional forces. Based on data from ten patients, proposals for the most demanding activities, the time courses of the contact forces and the required cycle numbers for testing are given here. Friction moments in the joint were measured in addition to the contact forces. The moment data were also standardized and can be applied to wear tests of the implant. It was shown that friction only very slightly influences the stresses in the implant neck and shaft.
format Online
Article
Text
id pubmed-4873223
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-48732232016-06-09 Standardized Loads Acting in Hip Implants Bergmann, Georg Bender, Alwina Dymke, Jörn Duda, Georg Damm, Philipp PLoS One Research Article With the increasing success of hip joint replacements, the average age of patients has decreased, patients have become more active and their expectations of the implant durability have risen. Thus, pre-clinical endurance tests on hip implants require defining realistic in vivo loads from younger and more active patients. These loads require simplifications to be applicable for simulator tests and numerical analyses. Here, the contact forces in the joint were measured with instrumented hip implants in ten subjects during nine of the most physically demanding and frequent activities of daily living. Typical levels and directions of average and high joint loads were extracted from the intra- and inter-individually widely varying individual data. These data can also be used to analyse bone remodelling at the implant-bone interface, evaluate tissue straining in finite element studies or validate analytical loading predictions, among other uses. The current ISO standards for endurance tests of implant stems and necks are based on historic analytical data from the 1970s. Comparisons of these test forces with in vivo loads unveiled that their unidirectional orientations deviate from the time-dependent in vivo directions during walking and most other activities. The ISO force for testing the stem is substantially too low while the ISO force for the neck better matches typical in vivo magnitudes. Because the magnitudes and orientations of peak forces substantially vary among the activities, load scenarios that reflect a collection of time-dependent high forces should be applied rather than using unidirectional forces. Based on data from ten patients, proposals for the most demanding activities, the time courses of the contact forces and the required cycle numbers for testing are given here. Friction moments in the joint were measured in addition to the contact forces. The moment data were also standardized and can be applied to wear tests of the implant. It was shown that friction only very slightly influences the stresses in the implant neck and shaft. Public Library of Science 2016-05-19 /pmc/articles/PMC4873223/ /pubmed/27195789 http://dx.doi.org/10.1371/journal.pone.0155612 Text en © 2016 Bergmann et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Bergmann, Georg
Bender, Alwina
Dymke, Jörn
Duda, Georg
Damm, Philipp
Standardized Loads Acting in Hip Implants
title Standardized Loads Acting in Hip Implants
title_full Standardized Loads Acting in Hip Implants
title_fullStr Standardized Loads Acting in Hip Implants
title_full_unstemmed Standardized Loads Acting in Hip Implants
title_short Standardized Loads Acting in Hip Implants
title_sort standardized loads acting in hip implants
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4873223/
https://www.ncbi.nlm.nih.gov/pubmed/27195789
http://dx.doi.org/10.1371/journal.pone.0155612
work_keys_str_mv AT bergmanngeorg standardizedloadsactinginhipimplants
AT benderalwina standardizedloadsactinginhipimplants
AT dymkejorn standardizedloadsactinginhipimplants
AT dudageorg standardizedloadsactinginhipimplants
AT dammphilipp standardizedloadsactinginhipimplants