Cargando…

Impact of heterogeneity-corrected dose calculation using a grid-based Boltzmann solver on breast and cervix cancer brachytherapy

PURPOSE: To analyze the impact of heterogeneity-corrected dose calculation on dosimetric quality parameters in gynecological and breast brachytherapy using Acuros, a grid-based Boltzmann equation solver (GBBS), and to evaluate the shielding effects of different cervix brachytherapy applicators. MATE...

Descripción completa

Detalles Bibliográficos
Autores principales: Hofbauer, Julia, Kirisits, Christian, Resch, Alexandra, Xu, Yingjie, Sturdza, Alina, Pötter, Richard, Nesvacil, Nicole
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4873554/
https://www.ncbi.nlm.nih.gov/pubmed/27257419
http://dx.doi.org/10.5114/jcb.2016.59352
_version_ 1782432899691184128
author Hofbauer, Julia
Kirisits, Christian
Resch, Alexandra
Xu, Yingjie
Sturdza, Alina
Pötter, Richard
Nesvacil, Nicole
author_facet Hofbauer, Julia
Kirisits, Christian
Resch, Alexandra
Xu, Yingjie
Sturdza, Alina
Pötter, Richard
Nesvacil, Nicole
author_sort Hofbauer, Julia
collection PubMed
description PURPOSE: To analyze the impact of heterogeneity-corrected dose calculation on dosimetric quality parameters in gynecological and breast brachytherapy using Acuros, a grid-based Boltzmann equation solver (GBBS), and to evaluate the shielding effects of different cervix brachytherapy applicators. MATERIAL AND METHODS: Calculations with TG-43 and Acuros were based on computed tomography (CT) retrospectively, for 10 cases of accelerated partial breast irradiation and 9 cervix cancer cases treated with tandem-ring applicators. Phantom CT-scans of different applicators (plastic and titanium) were acquired. For breast cases the V(20Gyαβ3) to lung, the D(0.1cm(3)), D(1cm(3)), D(2cm(3)) to rib, the D(0.1cm(3)), D(1cm(3)), D(10cm(3)) to skin, and D(max) for all structures were reported. For cervix cases, the D(0.1cm(3)), D(2cm(3)) to bladder, rectum and sigmoid, and the D(50), D(90), D(98), V(100) for the CTV(HR) were reported. For the phantom study, surrogates for target and organ at risk were created for a similar dose volume histogram (DVH) analysis. Absorbed dose and equivalent dose to 2 Gy fractionation (EQD2) were used for comparison. RESULTS: Calculations with TG-43 overestimated the dose for all dosimetric indices investigated. For breast, a decrease of ~8% was found for D(10cm(3)) to the skin and 5% for D(2cm(3)) to rib, resulting in a difference ~ –1.5 Gy EQD2 for overall treatment. Smaller effects were found for cervix cases with the plastic applicator, with up to –2% (–0.2 Gy EQD2) per fraction for organs at risk and –0.5% (–0.3 Gy EQD2) per fraction for CTV(HR). The shielding effect of the titanium applicator resulted in a decrease of 2% for D(2cm(3)) to the organ at risk versus 0.7% for plastic. CONCLUSIONS: Lower doses were reported when calculating with Acuros compared to TG-43. Differences in dose parameters were larger in breast cases. A lower impact on clinical dose parameters was found for the cervix cases. Applicator material causes systematic shielding effects that can be taken into account.
format Online
Article
Text
id pubmed-4873554
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-48735542016-06-02 Impact of heterogeneity-corrected dose calculation using a grid-based Boltzmann solver on breast and cervix cancer brachytherapy Hofbauer, Julia Kirisits, Christian Resch, Alexandra Xu, Yingjie Sturdza, Alina Pötter, Richard Nesvacil, Nicole J Contemp Brachytherapy Original Paper PURPOSE: To analyze the impact of heterogeneity-corrected dose calculation on dosimetric quality parameters in gynecological and breast brachytherapy using Acuros, a grid-based Boltzmann equation solver (GBBS), and to evaluate the shielding effects of different cervix brachytherapy applicators. MATERIAL AND METHODS: Calculations with TG-43 and Acuros were based on computed tomography (CT) retrospectively, for 10 cases of accelerated partial breast irradiation and 9 cervix cancer cases treated with tandem-ring applicators. Phantom CT-scans of different applicators (plastic and titanium) were acquired. For breast cases the V(20Gyαβ3) to lung, the D(0.1cm(3)), D(1cm(3)), D(2cm(3)) to rib, the D(0.1cm(3)), D(1cm(3)), D(10cm(3)) to skin, and D(max) for all structures were reported. For cervix cases, the D(0.1cm(3)), D(2cm(3)) to bladder, rectum and sigmoid, and the D(50), D(90), D(98), V(100) for the CTV(HR) were reported. For the phantom study, surrogates for target and organ at risk were created for a similar dose volume histogram (DVH) analysis. Absorbed dose and equivalent dose to 2 Gy fractionation (EQD2) were used for comparison. RESULTS: Calculations with TG-43 overestimated the dose for all dosimetric indices investigated. For breast, a decrease of ~8% was found for D(10cm(3)) to the skin and 5% for D(2cm(3)) to rib, resulting in a difference ~ –1.5 Gy EQD2 for overall treatment. Smaller effects were found for cervix cases with the plastic applicator, with up to –2% (–0.2 Gy EQD2) per fraction for organs at risk and –0.5% (–0.3 Gy EQD2) per fraction for CTV(HR). The shielding effect of the titanium applicator resulted in a decrease of 2% for D(2cm(3)) to the organ at risk versus 0.7% for plastic. CONCLUSIONS: Lower doses were reported when calculating with Acuros compared to TG-43. Differences in dose parameters were larger in breast cases. A lower impact on clinical dose parameters was found for the cervix cases. Applicator material causes systematic shielding effects that can be taken into account. Termedia Publishing House 2016-04-19 2016-04 /pmc/articles/PMC4873554/ /pubmed/27257419 http://dx.doi.org/10.5114/jcb.2016.59352 Text en Copyright © 2016 Termedia Sp. z o. o. http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
spellingShingle Original Paper
Hofbauer, Julia
Kirisits, Christian
Resch, Alexandra
Xu, Yingjie
Sturdza, Alina
Pötter, Richard
Nesvacil, Nicole
Impact of heterogeneity-corrected dose calculation using a grid-based Boltzmann solver on breast and cervix cancer brachytherapy
title Impact of heterogeneity-corrected dose calculation using a grid-based Boltzmann solver on breast and cervix cancer brachytherapy
title_full Impact of heterogeneity-corrected dose calculation using a grid-based Boltzmann solver on breast and cervix cancer brachytherapy
title_fullStr Impact of heterogeneity-corrected dose calculation using a grid-based Boltzmann solver on breast and cervix cancer brachytherapy
title_full_unstemmed Impact of heterogeneity-corrected dose calculation using a grid-based Boltzmann solver on breast and cervix cancer brachytherapy
title_short Impact of heterogeneity-corrected dose calculation using a grid-based Boltzmann solver on breast and cervix cancer brachytherapy
title_sort impact of heterogeneity-corrected dose calculation using a grid-based boltzmann solver on breast and cervix cancer brachytherapy
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4873554/
https://www.ncbi.nlm.nih.gov/pubmed/27257419
http://dx.doi.org/10.5114/jcb.2016.59352
work_keys_str_mv AT hofbauerjulia impactofheterogeneitycorrecteddosecalculationusingagridbasedboltzmannsolveronbreastandcervixcancerbrachytherapy
AT kirisitschristian impactofheterogeneitycorrecteddosecalculationusingagridbasedboltzmannsolveronbreastandcervixcancerbrachytherapy
AT reschalexandra impactofheterogeneitycorrecteddosecalculationusingagridbasedboltzmannsolveronbreastandcervixcancerbrachytherapy
AT xuyingjie impactofheterogeneitycorrecteddosecalculationusingagridbasedboltzmannsolveronbreastandcervixcancerbrachytherapy
AT sturdzaalina impactofheterogeneitycorrecteddosecalculationusingagridbasedboltzmannsolveronbreastandcervixcancerbrachytherapy
AT potterrichard impactofheterogeneitycorrecteddosecalculationusingagridbasedboltzmannsolveronbreastandcervixcancerbrachytherapy
AT nesvacilnicole impactofheterogeneitycorrecteddosecalculationusingagridbasedboltzmannsolveronbreastandcervixcancerbrachytherapy