The risk of intra-urethral Foley catheter balloon inflation in spinal cord-injured patients: Lessons learned from a retrospective case series

BACKGROUND: Inflating the balloon of Foley catheter in urethra is a complication of urethral catheterisation. We report five patients in whom this complication occurred because of unskilled catheterisation. Due to lack of awareness, the problem was not recognised promptly and patients came to harm....

Descripción completa

Detalles Bibliográficos
Autores principales: Subramanian, Vaidyanathan, Soni, Bakul M., Hughes, Peter L., Singh, Gurpreet, Oo, Tun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4875696/
https://www.ncbi.nlm.nih.gov/pubmed/27213016
http://dx.doi.org/10.1186/s13037-016-0101-1
_version_ 1782433140265975808
author Subramanian, Vaidyanathan
Soni, Bakul M.
Hughes, Peter L.
Singh, Gurpreet
Oo, Tun
author_facet Subramanian, Vaidyanathan
Soni, Bakul M.
Hughes, Peter L.
Singh, Gurpreet
Oo, Tun
author_sort Subramanian, Vaidyanathan
collection PubMed
description BACKGROUND: Inflating the balloon of Foley catheter in urethra is a complication of urethral catheterisation. We report five patients in whom this complication occurred because of unskilled catheterisation. Due to lack of awareness, the problem was not recognised promptly and patients came to harm. CASE SERIES: 1. A tetraplegic patient developed pain in lower abdomen and became unwell after transurethral catheterisation. CT pelvis revealed full bladder with balloon of Foley catheter in dilated urethra. 2. Routine ultrasound examination in an asymptomatic tetraplegic patient with urethral catheter drainage, revealed Foley balloon in the urethra. He was advised to get catheterisations done by senior health professionals. 3. A paraplegic patient developed bleeding and bypassing after transurethral catheterisation. X-ray revealed Foley balloon in urethra; urethral catheter was changed ensuring its correct placement in urinary bladder. Subsequently, balloon of Foley catheter was inflated in urethra several times by community nurses, which resulted in erosion of bulbous urethra and urinary fistula. Suprapubic cystostomy was performed. 4. A tetraplegic patient developed sweating and increased spasms following urethral catheterisations. CT of abdomen revealed distended bladder with the balloon of Foley catheter located in urethra. Flexible cystoscopy and transurethral catheterisation over a guide-wire were performed. Patient noticed decrease in sweating and spasms. 5. A paraplegic patient developed lower abdominal pain and nausea following catheterisation. CT abdomen revealed bilateral hydronephrosis and hydroureter and Foley balloon located in urethra. Urehral catheterisation was performed over a guide-wire after cystoscopy. Subsequently suprapubic cystostomy was done. CONCLUSION: Spinal cord injury patients are at increased risk for intra-urethral Foley catheter balloon inflation because of lack of sensation in urethra, urethral sphincter spasm, and false passage due to previous urethral trauma. Education and training of doctors and nurses in proper technique of catheterisation in spinal cord injury patients is vital to prevent intra-urethral inflation of Foley catheter balloon. If a spinal cord injury patient develops bypassing or symptoms of autonomic dysreflexia following catheterisation, incorrect placement of urethral catheter should be suspected.
format Online
Article
Text
id pubmed-4875696
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-48756962016-05-22 The risk of intra-urethral Foley catheter balloon inflation in spinal cord-injured patients: Lessons learned from a retrospective case series Subramanian, Vaidyanathan Soni, Bakul M. Hughes, Peter L. Singh, Gurpreet Oo, Tun Patient Saf Surg Short Report BACKGROUND: Inflating the balloon of Foley catheter in urethra is a complication of urethral catheterisation. We report five patients in whom this complication occurred because of unskilled catheterisation. Due to lack of awareness, the problem was not recognised promptly and patients came to harm. CASE SERIES: 1. A tetraplegic patient developed pain in lower abdomen and became unwell after transurethral catheterisation. CT pelvis revealed full bladder with balloon of Foley catheter in dilated urethra. 2. Routine ultrasound examination in an asymptomatic tetraplegic patient with urethral catheter drainage, revealed Foley balloon in the urethra. He was advised to get catheterisations done by senior health professionals. 3. A paraplegic patient developed bleeding and bypassing after transurethral catheterisation. X-ray revealed Foley balloon in urethra; urethral catheter was changed ensuring its correct placement in urinary bladder. Subsequently, balloon of Foley catheter was inflated in urethra several times by community nurses, which resulted in erosion of bulbous urethra and urinary fistula. Suprapubic cystostomy was performed. 4. A tetraplegic patient developed sweating and increased spasms following urethral catheterisations. CT of abdomen revealed distended bladder with the balloon of Foley catheter located in urethra. Flexible cystoscopy and transurethral catheterisation over a guide-wire were performed. Patient noticed decrease in sweating and spasms. 5. A paraplegic patient developed lower abdominal pain and nausea following catheterisation. CT abdomen revealed bilateral hydronephrosis and hydroureter and Foley balloon located in urethra. Urehral catheterisation was performed over a guide-wire after cystoscopy. Subsequently suprapubic cystostomy was done. CONCLUSION: Spinal cord injury patients are at increased risk for intra-urethral Foley catheter balloon inflation because of lack of sensation in urethra, urethral sphincter spasm, and false passage due to previous urethral trauma. Education and training of doctors and nurses in proper technique of catheterisation in spinal cord injury patients is vital to prevent intra-urethral inflation of Foley catheter balloon. If a spinal cord injury patient develops bypassing or symptoms of autonomic dysreflexia following catheterisation, incorrect placement of urethral catheter should be suspected. BioMed Central 2016-05-21 /pmc/articles/PMC4875696/ /pubmed/27213016 http://dx.doi.org/10.1186/s13037-016-0101-1 Text en © Vaidyanathan et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Short Report
Subramanian, Vaidyanathan
Soni, Bakul M.
Hughes, Peter L.
Singh, Gurpreet
Oo, Tun
The risk of intra-urethral Foley catheter balloon inflation in spinal cord-injured patients: Lessons learned from a retrospective case series
title The risk of intra-urethral Foley catheter balloon inflation in spinal cord-injured patients: Lessons learned from a retrospective case series
title_full The risk of intra-urethral Foley catheter balloon inflation in spinal cord-injured patients: Lessons learned from a retrospective case series
title_fullStr The risk of intra-urethral Foley catheter balloon inflation in spinal cord-injured patients: Lessons learned from a retrospective case series
title_full_unstemmed The risk of intra-urethral Foley catheter balloon inflation in spinal cord-injured patients: Lessons learned from a retrospective case series
title_short The risk of intra-urethral Foley catheter balloon inflation in spinal cord-injured patients: Lessons learned from a retrospective case series
title_sort risk of intra-urethral foley catheter balloon inflation in spinal cord-injured patients: lessons learned from a retrospective case series
topic Short Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4875696/
https://www.ncbi.nlm.nih.gov/pubmed/27213016
http://dx.doi.org/10.1186/s13037-016-0101-1
work_keys_str_mv AT subramanianvaidyanathan theriskofintraurethralfoleycatheterballooninflationinspinalcordinjuredpatientslessonslearnedfromaretrospectivecaseseries
AT sonibakulm theriskofintraurethralfoleycatheterballooninflationinspinalcordinjuredpatientslessonslearnedfromaretrospectivecaseseries
AT hughespeterl theriskofintraurethralfoleycatheterballooninflationinspinalcordinjuredpatientslessonslearnedfromaretrospectivecaseseries
AT singhgurpreet theriskofintraurethralfoleycatheterballooninflationinspinalcordinjuredpatientslessonslearnedfromaretrospectivecaseseries
AT ootun theriskofintraurethralfoleycatheterballooninflationinspinalcordinjuredpatientslessonslearnedfromaretrospectivecaseseries
AT subramanianvaidyanathan riskofintraurethralfoleycatheterballooninflationinspinalcordinjuredpatientslessonslearnedfromaretrospectivecaseseries
AT sonibakulm riskofintraurethralfoleycatheterballooninflationinspinalcordinjuredpatientslessonslearnedfromaretrospectivecaseseries
AT hughespeterl riskofintraurethralfoleycatheterballooninflationinspinalcordinjuredpatientslessonslearnedfromaretrospectivecaseseries
AT singhgurpreet riskofintraurethralfoleycatheterballooninflationinspinalcordinjuredpatientslessonslearnedfromaretrospectivecaseseries
AT ootun riskofintraurethralfoleycatheterballooninflationinspinalcordinjuredpatientslessonslearnedfromaretrospectivecaseseries