Cargando…
Low-Dose (10%) Computed Tomography May Be Inferior to Standard-Dose CT in the Evaluation of Acute Renal Colic in the Emergency Room Setting
Introduction: Noncontrast CT is the standard of care to evaluate nephrolithiasis. We evaluated the performance of low-dose CT (LDCT) scan for evaluation of renal colic in the emergency room (ER). Materials and Methods: Patients visiting the ER with suspected nephrolithiasis received a standard-dose...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Mary Ann Liebert, Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4876551/ https://www.ncbi.nlm.nih.gov/pubmed/26728321 http://dx.doi.org/10.1089/end.2015.0760 |
_version_ | 1782433254999064576 |
---|---|
author | Malkawi, Ibraheem M. Han, Esther Atalla, Christopher S. Santucci, Richard A. O'Neil, Brian Wynberg, Jason B. |
author_facet | Malkawi, Ibraheem M. Han, Esther Atalla, Christopher S. Santucci, Richard A. O'Neil, Brian Wynberg, Jason B. |
author_sort | Malkawi, Ibraheem M. |
collection | PubMed |
description | Introduction: Noncontrast CT is the standard of care to evaluate nephrolithiasis. We evaluated the performance of low-dose CT (LDCT) scan for evaluation of renal colic in the emergency room (ER). Materials and Methods: Patients visiting the ER with suspected nephrolithiasis received a standard-dose CT (SDCT) and an LDCT. Two urologists read the LDCTs and later they read SDCTs. Stone information was recorded on a diagram of the renal system. Findings on SDCTs and LDCTs were correlated through side-by-side comparison of the diagrams. Later, the two urologists adjudicated all nonconcordance between SDCTs and LDCTs in an unblinded manner. Results: Twenty-seven patients were included. SDCTs revealed 27 stones in 18 patients. Mean stone size was 3.81 mm. LDCTs revealed 27 stones in 18 patients with a mean stone size of 4.7 mm (p = 0.23). Overall sensitivity and specificity of LDCTs were 70% and 39%, respectively. There were eight false-positive and eight false-negative stones. All the false-positive stones on LDCTs were placed in the ureter, in which all of the corresponding SDCTs were visible calcifications outside the ureter. Of the eight false-negative stones on LDCTs, seven were visible calcifications on the SDCTs and the eighth stone was 1 mm and was not visible. Conclusion: LDCT may not perform well in the evaluation of suspected nephrolithiasis in the acute setting. LDCT scan accurately demonstrates calcifications; however, accurate placement of calcifications in or out of the urinary tract may be diminished due to impaired resolution of soft tissue structures. |
format | Online Article Text |
id | pubmed-4876551 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Mary Ann Liebert, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-48765512016-06-07 Low-Dose (10%) Computed Tomography May Be Inferior to Standard-Dose CT in the Evaluation of Acute Renal Colic in the Emergency Room Setting Malkawi, Ibraheem M. Han, Esther Atalla, Christopher S. Santucci, Richard A. O'Neil, Brian Wynberg, Jason B. J Endourol Imaging and Noninvasive Therapy Introduction: Noncontrast CT is the standard of care to evaluate nephrolithiasis. We evaluated the performance of low-dose CT (LDCT) scan for evaluation of renal colic in the emergency room (ER). Materials and Methods: Patients visiting the ER with suspected nephrolithiasis received a standard-dose CT (SDCT) and an LDCT. Two urologists read the LDCTs and later they read SDCTs. Stone information was recorded on a diagram of the renal system. Findings on SDCTs and LDCTs were correlated through side-by-side comparison of the diagrams. Later, the two urologists adjudicated all nonconcordance between SDCTs and LDCTs in an unblinded manner. Results: Twenty-seven patients were included. SDCTs revealed 27 stones in 18 patients. Mean stone size was 3.81 mm. LDCTs revealed 27 stones in 18 patients with a mean stone size of 4.7 mm (p = 0.23). Overall sensitivity and specificity of LDCTs were 70% and 39%, respectively. There were eight false-positive and eight false-negative stones. All the false-positive stones on LDCTs were placed in the ureter, in which all of the corresponding SDCTs were visible calcifications outside the ureter. Of the eight false-negative stones on LDCTs, seven were visible calcifications on the SDCTs and the eighth stone was 1 mm and was not visible. Conclusion: LDCT may not perform well in the evaluation of suspected nephrolithiasis in the acute setting. LDCT scan accurately demonstrates calcifications; however, accurate placement of calcifications in or out of the urinary tract may be diminished due to impaired resolution of soft tissue structures. Mary Ann Liebert, Inc. 2016-05-01 /pmc/articles/PMC4876551/ /pubmed/26728321 http://dx.doi.org/10.1089/end.2015.0760 Text en © Ibraheem M. Malkawi et al. 2016; Published by Mary Ann Liebert, Inc. This Open Access article is distributed under the terms of the Creative Commons Attribution Noncommercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited. |
spellingShingle | Imaging and Noninvasive Therapy Malkawi, Ibraheem M. Han, Esther Atalla, Christopher S. Santucci, Richard A. O'Neil, Brian Wynberg, Jason B. Low-Dose (10%) Computed Tomography May Be Inferior to Standard-Dose CT in the Evaluation of Acute Renal Colic in the Emergency Room Setting |
title | Low-Dose (10%) Computed Tomography May Be Inferior to Standard-Dose CT in the Evaluation of Acute Renal Colic in the Emergency Room Setting |
title_full | Low-Dose (10%) Computed Tomography May Be Inferior to Standard-Dose CT in the Evaluation of Acute Renal Colic in the Emergency Room Setting |
title_fullStr | Low-Dose (10%) Computed Tomography May Be Inferior to Standard-Dose CT in the Evaluation of Acute Renal Colic in the Emergency Room Setting |
title_full_unstemmed | Low-Dose (10%) Computed Tomography May Be Inferior to Standard-Dose CT in the Evaluation of Acute Renal Colic in the Emergency Room Setting |
title_short | Low-Dose (10%) Computed Tomography May Be Inferior to Standard-Dose CT in the Evaluation of Acute Renal Colic in the Emergency Room Setting |
title_sort | low-dose (10%) computed tomography may be inferior to standard-dose ct in the evaluation of acute renal colic in the emergency room setting |
topic | Imaging and Noninvasive Therapy |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4876551/ https://www.ncbi.nlm.nih.gov/pubmed/26728321 http://dx.doi.org/10.1089/end.2015.0760 |
work_keys_str_mv | AT malkawiibraheemm lowdose10computedtomographymaybeinferiortostandarddosectintheevaluationofacuterenalcolicintheemergencyroomsetting AT hanesther lowdose10computedtomographymaybeinferiortostandarddosectintheevaluationofacuterenalcolicintheemergencyroomsetting AT atallachristophers lowdose10computedtomographymaybeinferiortostandarddosectintheevaluationofacuterenalcolicintheemergencyroomsetting AT santucciricharda lowdose10computedtomographymaybeinferiortostandarddosectintheevaluationofacuterenalcolicintheemergencyroomsetting AT oneilbrian lowdose10computedtomographymaybeinferiortostandarddosectintheevaluationofacuterenalcolicintheemergencyroomsetting AT wynbergjasonb lowdose10computedtomographymaybeinferiortostandarddosectintheevaluationofacuterenalcolicintheemergencyroomsetting |