Cargando…

Comparison of the NIST and BIPM Air-Kerma Standards for Measurements in the Low-Energy X-Ray Range

A direct comparison was made between the air-kerma standards used for the measurement of low-energy x rays at the National Institute of Standards and Technology (NIST) and the Bureau International des Poids et Mesures (BIPM). The comparison was carried out at the BIPM using the BIPM reference beam q...

Descripción completa

Detalles Bibliográficos
Autores principales: Burns, D. T., Lamperti, P., O’Brien, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1999
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4877116/
http://dx.doi.org/10.6028/jres.104.009
_version_ 1782433335334666240
author Burns, D. T.
Lamperti, P.
O’Brien, M.
author_facet Burns, D. T.
Lamperti, P.
O’Brien, M.
author_sort Burns, D. T.
collection PubMed
description A direct comparison was made between the air-kerma standards used for the measurement of low-energy x rays at the National Institute of Standards and Technology (NIST) and the Bureau International des Poids et Mesures (BIPM). The comparison was carried out at the BIPM using the BIPM reference beam qualities in the range from 10 kV to 100 kV. The results show the standards to be in agreement to around 0.5 % at reference beam qualities up to 50 kV and at 100 kV. The result at the 80 kV beam quality is less favorable, with agreement at the 1 % level.
format Online
Article
Text
id pubmed-4877116
institution National Center for Biotechnology Information
language English
publishDate 1999
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-48771162016-09-06 Comparison of the NIST and BIPM Air-Kerma Standards for Measurements in the Low-Energy X-Ray Range Burns, D. T. Lamperti, P. O’Brien, M. J Res Natl Inst Stand Technol Article A direct comparison was made between the air-kerma standards used for the measurement of low-energy x rays at the National Institute of Standards and Technology (NIST) and the Bureau International des Poids et Mesures (BIPM). The comparison was carried out at the BIPM using the BIPM reference beam qualities in the range from 10 kV to 100 kV. The results show the standards to be in agreement to around 0.5 % at reference beam qualities up to 50 kV and at 100 kV. The result at the 80 kV beam quality is less favorable, with agreement at the 1 % level. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1999 1999-04-01 /pmc/articles/PMC4877116/ http://dx.doi.org/10.6028/jres.104.009 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Burns, D. T.
Lamperti, P.
O’Brien, M.
Comparison of the NIST and BIPM Air-Kerma Standards for Measurements in the Low-Energy X-Ray Range
title Comparison of the NIST and BIPM Air-Kerma Standards for Measurements in the Low-Energy X-Ray Range
title_full Comparison of the NIST and BIPM Air-Kerma Standards for Measurements in the Low-Energy X-Ray Range
title_fullStr Comparison of the NIST and BIPM Air-Kerma Standards for Measurements in the Low-Energy X-Ray Range
title_full_unstemmed Comparison of the NIST and BIPM Air-Kerma Standards for Measurements in the Low-Energy X-Ray Range
title_short Comparison of the NIST and BIPM Air-Kerma Standards for Measurements in the Low-Energy X-Ray Range
title_sort comparison of the nist and bipm air-kerma standards for measurements in the low-energy x-ray range
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4877116/
http://dx.doi.org/10.6028/jres.104.009
work_keys_str_mv AT burnsdt comparisonofthenistandbipmairkermastandardsformeasurementsinthelowenergyxrayrange
AT lampertip comparisonofthenistandbipmairkermastandardsformeasurementsinthelowenergyxrayrange
AT obrienm comparisonofthenistandbipmairkermastandardsformeasurementsinthelowenergyxrayrange