Cargando…
Comparison of the NIST and BIPM Air-Kerma Standards for Measurements in the Low-Energy X-Ray Range
A direct comparison was made between the air-kerma standards used for the measurement of low-energy x rays at the National Institute of Standards and Technology (NIST) and the Bureau International des Poids et Mesures (BIPM). The comparison was carried out at the BIPM using the BIPM reference beam q...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
[Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
1999
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4877116/ http://dx.doi.org/10.6028/jres.104.009 |
_version_ | 1782433335334666240 |
---|---|
author | Burns, D. T. Lamperti, P. O’Brien, M. |
author_facet | Burns, D. T. Lamperti, P. O’Brien, M. |
author_sort | Burns, D. T. |
collection | PubMed |
description | A direct comparison was made between the air-kerma standards used for the measurement of low-energy x rays at the National Institute of Standards and Technology (NIST) and the Bureau International des Poids et Mesures (BIPM). The comparison was carried out at the BIPM using the BIPM reference beam qualities in the range from 10 kV to 100 kV. The results show the standards to be in agreement to around 0.5 % at reference beam qualities up to 50 kV and at 100 kV. The result at the 80 kV beam quality is less favorable, with agreement at the 1 % level. |
format | Online Article Text |
id | pubmed-4877116 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1999 |
publisher | [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology |
record_format | MEDLINE/PubMed |
spelling | pubmed-48771162016-09-06 Comparison of the NIST and BIPM Air-Kerma Standards for Measurements in the Low-Energy X-Ray Range Burns, D. T. Lamperti, P. O’Brien, M. J Res Natl Inst Stand Technol Article A direct comparison was made between the air-kerma standards used for the measurement of low-energy x rays at the National Institute of Standards and Technology (NIST) and the Bureau International des Poids et Mesures (BIPM). The comparison was carried out at the BIPM using the BIPM reference beam qualities in the range from 10 kV to 100 kV. The results show the standards to be in agreement to around 0.5 % at reference beam qualities up to 50 kV and at 100 kV. The result at the 80 kV beam quality is less favorable, with agreement at the 1 % level. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1999 1999-04-01 /pmc/articles/PMC4877116/ http://dx.doi.org/10.6028/jres.104.009 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright. |
spellingShingle | Article Burns, D. T. Lamperti, P. O’Brien, M. Comparison of the NIST and BIPM Air-Kerma Standards for Measurements in the Low-Energy X-Ray Range |
title | Comparison of the NIST and BIPM Air-Kerma Standards for Measurements in the Low-Energy X-Ray Range |
title_full | Comparison of the NIST and BIPM Air-Kerma Standards for Measurements in the Low-Energy X-Ray Range |
title_fullStr | Comparison of the NIST and BIPM Air-Kerma Standards for Measurements in the Low-Energy X-Ray Range |
title_full_unstemmed | Comparison of the NIST and BIPM Air-Kerma Standards for Measurements in the Low-Energy X-Ray Range |
title_short | Comparison of the NIST and BIPM Air-Kerma Standards for Measurements in the Low-Energy X-Ray Range |
title_sort | comparison of the nist and bipm air-kerma standards for measurements in the low-energy x-ray range |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4877116/ http://dx.doi.org/10.6028/jres.104.009 |
work_keys_str_mv | AT burnsdt comparisonofthenistandbipmairkermastandardsformeasurementsinthelowenergyxrayrange AT lampertip comparisonofthenistandbipmairkermastandardsformeasurementsinthelowenergyxrayrange AT obrienm comparisonofthenistandbipmairkermastandardsformeasurementsinthelowenergyxrayrange |