The NIST Quantitative Infrared Database
With the recent developments in Fourier transform infrared (FTIR) spectrometers it is becoming more feasible to place these instruments in field environments. As a result, there has been enormous increase in the use of FTIR techniques for a variety of qualitative and quantitative chemical measuremen...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
[Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
1999
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4877123/ http://dx.doi.org/10.6028/jres.104.004 |
_version_ | 1782433336990367744 |
---|---|
author | Chu, P. M. Guenther, F. R. Rhoderick, G. C. Lafferty, W. J. |
author_facet | Chu, P. M. Guenther, F. R. Rhoderick, G. C. Lafferty, W. J. |
author_sort | Chu, P. M. |
collection | PubMed |
description | With the recent developments in Fourier transform infrared (FTIR) spectrometers it is becoming more feasible to place these instruments in field environments. As a result, there has been enormous increase in the use of FTIR techniques for a variety of qualitative and quantitative chemical measurements. These methods offer the possibility of fully automated real-time quantitation of many analytes; therefore FTIR has great potential as an analytical tool. Recently, the U.S. Environmental Protection Agency (U.S.EPA) has developed protocol methods for emissions monitoring using both extractive and open-path FTIR measurements. Depending upon the analyte, the experimental conditions and the analyte matrix, approximately 100 of the hazardous air pollutants (HAPs) listed in the 1990 U.S.EPA Clean Air Act amendment (CAAA) can be measured. The National Institute of Standards and Technology (NIST) has initiated a program to provide quality-assured infrared absorption coefficient data based on NIST prepared primary gas standards. Currently, absorption coefficient data has been acquired for approximately 20 of the HAPs. For each compound, the absorption coefficient spectrum was calculated using nine transmittance spectra at 0.12 cm(−1) resolution and the Beer’s law relationship. The uncertainties in the absorption coefficient data were estimated from the linear regressions of the transmittance data and considerations of other error sources such as the nonlinear detector response. For absorption coefficient values greater than 1 × 10(−4) μmol/mol)(−1) m(−1) the average relative expanded uncertainty is 2.2 %. This quantitative infrared database is currently an ongoing project at NIST. Additional spectra will be added to the database as they are acquired. Our current plans include continued data acquisition of the compounds listed in the CAAA, as well as the compounds that contribute to global warming and ozone depletion. |
format | Online Article Text |
id | pubmed-4877123 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1999 |
publisher | [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology |
record_format | MEDLINE/PubMed |
spelling | pubmed-48771232016-09-06 The NIST Quantitative Infrared Database Chu, P. M. Guenther, F. R. Rhoderick, G. C. Lafferty, W. J. J Res Natl Inst Stand Technol Article With the recent developments in Fourier transform infrared (FTIR) spectrometers it is becoming more feasible to place these instruments in field environments. As a result, there has been enormous increase in the use of FTIR techniques for a variety of qualitative and quantitative chemical measurements. These methods offer the possibility of fully automated real-time quantitation of many analytes; therefore FTIR has great potential as an analytical tool. Recently, the U.S. Environmental Protection Agency (U.S.EPA) has developed protocol methods for emissions monitoring using both extractive and open-path FTIR measurements. Depending upon the analyte, the experimental conditions and the analyte matrix, approximately 100 of the hazardous air pollutants (HAPs) listed in the 1990 U.S.EPA Clean Air Act amendment (CAAA) can be measured. The National Institute of Standards and Technology (NIST) has initiated a program to provide quality-assured infrared absorption coefficient data based on NIST prepared primary gas standards. Currently, absorption coefficient data has been acquired for approximately 20 of the HAPs. For each compound, the absorption coefficient spectrum was calculated using nine transmittance spectra at 0.12 cm(−1) resolution and the Beer’s law relationship. The uncertainties in the absorption coefficient data were estimated from the linear regressions of the transmittance data and considerations of other error sources such as the nonlinear detector response. For absorption coefficient values greater than 1 × 10(−4) μmol/mol)(−1) m(−1) the average relative expanded uncertainty is 2.2 %. This quantitative infrared database is currently an ongoing project at NIST. Additional spectra will be added to the database as they are acquired. Our current plans include continued data acquisition of the compounds listed in the CAAA, as well as the compounds that contribute to global warming and ozone depletion. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1999 1999-02-01 /pmc/articles/PMC4877123/ http://dx.doi.org/10.6028/jres.104.004 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright. |
spellingShingle | Article Chu, P. M. Guenther, F. R. Rhoderick, G. C. Lafferty, W. J. The NIST Quantitative Infrared Database |
title | The NIST Quantitative Infrared Database |
title_full | The NIST Quantitative Infrared Database |
title_fullStr | The NIST Quantitative Infrared Database |
title_full_unstemmed | The NIST Quantitative Infrared Database |
title_short | The NIST Quantitative Infrared Database |
title_sort | nist quantitative infrared database |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4877123/ http://dx.doi.org/10.6028/jres.104.004 |
work_keys_str_mv | AT chupm thenistquantitativeinfrareddatabase AT guentherfr thenistquantitativeinfrareddatabase AT rhoderickgc thenistquantitativeinfrareddatabase AT laffertywj thenistquantitativeinfrareddatabase AT chupm nistquantitativeinfrareddatabase AT guentherfr nistquantitativeinfrareddatabase AT rhoderickgc nistquantitativeinfrareddatabase AT laffertywj nistquantitativeinfrareddatabase |