Cargando…
Massic Activity Ratios of the NBS/NIST Tritiated-Water Standards Issued Between 1954 and 1999
As part of the preparation and calibration of three new National Institute of Standards and Technology (NIST) tritiated-water radioactivity Standard Reference Materials (SRMs), the massic-activity (activity of the sample divided by the mass of the sample) ratios of all of the available NBS/NIST trit...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
[Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
2000
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4877154/ https://www.ncbi.nlm.nih.gov/pubmed/27551620 http://dx.doi.org/10.6028/jres.105.042 |
_version_ | 1782433341695328256 |
---|---|
author | Lucas, L. L. |
author_facet | Lucas, L. L. |
author_sort | Lucas, L. L. |
collection | PubMed |
description | As part of the preparation and calibration of three new National Institute of Standards and Technology (NIST) tritiated-water radioactivity Standard Reference Materials (SRMs), the massic-activity (activity of the sample divided by the mass of the sample) ratios of all of the available NBS/NIST tritiated-water SRMs issued between 1954 and 1999 were measured using liquid-scintillation (LS) counting. Four of the tritiated-water standards (SRMs 4361, 4926B, 4927C, and 4927D) were not available for measurement. All of the other tritiated-water standards (SRMs 4361B, 4361C, 4926, 4926C, 4926D, 4926E, 4927, 4927B, 4927E, and 4927F) were available, having been stored in flame-sealed glass ampoules. Where possible, massic-activity ratios measured by liquid-scintillation counting are compared with massic-activity ratios calculated from gravimetric dilution factors. The agreement is well within the stated uncertainties. For two of the tritiated-water standards that were not available for measurement (SRMs 4361 and 4926B), massic-activity ratios calculated from gravimetric dilution factors are available. |
format | Online Article Text |
id | pubmed-4877154 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2000 |
publisher | [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology |
record_format | MEDLINE/PubMed |
spelling | pubmed-48771542016-08-22 Massic Activity Ratios of the NBS/NIST Tritiated-Water Standards Issued Between 1954 and 1999 Lucas, L. L. J Res Natl Inst Stand Technol Article As part of the preparation and calibration of three new National Institute of Standards and Technology (NIST) tritiated-water radioactivity Standard Reference Materials (SRMs), the massic-activity (activity of the sample divided by the mass of the sample) ratios of all of the available NBS/NIST tritiated-water SRMs issued between 1954 and 1999 were measured using liquid-scintillation (LS) counting. Four of the tritiated-water standards (SRMs 4361, 4926B, 4927C, and 4927D) were not available for measurement. All of the other tritiated-water standards (SRMs 4361B, 4361C, 4926, 4926C, 4926D, 4926E, 4927, 4927B, 4927E, and 4927F) were available, having been stored in flame-sealed glass ampoules. Where possible, massic-activity ratios measured by liquid-scintillation counting are compared with massic-activity ratios calculated from gravimetric dilution factors. The agreement is well within the stated uncertainties. For two of the tritiated-water standards that were not available for measurement (SRMs 4361 and 4926B), massic-activity ratios calculated from gravimetric dilution factors are available. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2000 2000-08-01 /pmc/articles/PMC4877154/ /pubmed/27551620 http://dx.doi.org/10.6028/jres.105.042 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright. |
spellingShingle | Article Lucas, L. L. Massic Activity Ratios of the NBS/NIST Tritiated-Water Standards Issued Between 1954 and 1999 |
title | Massic Activity Ratios of the NBS/NIST Tritiated-Water Standards Issued Between 1954 and 1999 |
title_full | Massic Activity Ratios of the NBS/NIST Tritiated-Water Standards Issued Between 1954 and 1999 |
title_fullStr | Massic Activity Ratios of the NBS/NIST Tritiated-Water Standards Issued Between 1954 and 1999 |
title_full_unstemmed | Massic Activity Ratios of the NBS/NIST Tritiated-Water Standards Issued Between 1954 and 1999 |
title_short | Massic Activity Ratios of the NBS/NIST Tritiated-Water Standards Issued Between 1954 and 1999 |
title_sort | massic activity ratios of the nbs/nist tritiated-water standards issued between 1954 and 1999 |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4877154/ https://www.ncbi.nlm.nih.gov/pubmed/27551620 http://dx.doi.org/10.6028/jres.105.042 |
work_keys_str_mv | AT lucasll massicactivityratiosofthenbsnisttritiatedwaterstandardsissuedbetween1954and1999 |