Cargando…

Thermal-Conductivity Apparatus for Steady-State, Comparative Measurement of Ceramic Coatings

An apparatus has been developed to measure the thermal conductivity of ceramic coatings. Since the method uses an infrared microscope for temperature measurement, coatings as thin as 20 μm can, in principle, be measured using this technique. This steady-state, comparative measurement method uses the...

Descripción completa

Detalles Bibliográficos
Autor principal: Slifka, A. J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2000
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4877160/
https://www.ncbi.nlm.nih.gov/pubmed/27551628
http://dx.doi.org/10.6028/jres.105.050
Descripción
Sumario:An apparatus has been developed to measure the thermal conductivity of ceramic coatings. Since the method uses an infrared microscope for temperature measurement, coatings as thin as 20 μm can, in principle, be measured using this technique. This steady-state, comparative measurement method uses the known thermal conductivity of the substrate material as the reference material for heat-flow measurement. The experimental method is validated by measuring a plasma-sprayed coating that has been previously measured using an absolute, steady-state measurement method. The new measurement method has a relative standard uncertainty of about 10 %. The measurement of the plasma-sprayed coating gives 0.58 W·m(−1)·K(−l) which compares well with the 0.62 W·m(−1)·K(−l) measured using the absolute method.