Cargando…

Clinical and echocardiographic characteristics associated with the evolution of the ductus arteriosus in the neonate with birth weight lower than 1,500g

OBJECTIVE: To identify clinical and echocardiographic parameters associated with the evolution of the ductus arteriosus in neonates with birth weight lower than 1,500g. METHODS: Retrospective study of 119 neonates in which clinical parameters (Prenatal: maternal age, risk of infection and chorioamni...

Descripción completa

Detalles Bibliográficos
Autores principales: Visconti, Luiza Fortunato, Morhy, Samira Saady, Deutsch, Alice D'Agostini, Tavares, Gláucia Maria Penha, Wilberg, Tatiana Jardim Mussi, Rossi, Felipe de Souza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Instituto Israelita de Ensino e Pesquisa Albert Einstein 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4878590/
https://www.ncbi.nlm.nih.gov/pubmed/24136758
http://dx.doi.org/10.1590/S1679-45082013000300010
_version_ 1782433580818890752
author Visconti, Luiza Fortunato
Morhy, Samira Saady
Deutsch, Alice D'Agostini
Tavares, Gláucia Maria Penha
Wilberg, Tatiana Jardim Mussi
Rossi, Felipe de Souza
author_facet Visconti, Luiza Fortunato
Morhy, Samira Saady
Deutsch, Alice D'Agostini
Tavares, Gláucia Maria Penha
Wilberg, Tatiana Jardim Mussi
Rossi, Felipe de Souza
author_sort Visconti, Luiza Fortunato
collection PubMed
description OBJECTIVE: To identify clinical and echocardiographic parameters associated with the evolution of the ductus arteriosus in neonates with birth weight lower than 1,500g. METHODS: Retrospective study of 119 neonates in which clinical parameters (Prenatal: maternal age, risk of infection and chorioamnionitis, use of corticosteroid, mode of delivery and gestational age. Perinatal: weight, Apgar score, gender and birth weight/gestational age classification; Postnatal: use of surfactant, sepsis, fluid intake, heart murmur, heart rate, precordial movement and pulses, use of diuretics, oxygenation index, desaturation/apnea, ventilatory support, food intolerance, chest radiography, renal function, hemodynamic instability, and metabolic changes) and echocardiographic parameters (ductus arteriosus diameter, ductus arteriosus/weight ratio, left atrium/ aorta ratio, left ventricular diastolic diameter, and transductal flow direction, pattern and velocity) were analyzed. The clinical and echocardiographic parameters analyzed were considered statistically significant when p<0.05. RESULTS: In the 119 neonates, the incidence of patent ductus arteriosus was 61.3%; 56 received treatment (46 pharmacological and 10 surgical treatment), 11 had spontaneous closure, 4 died, and 2 were discharged with patent ductus arteriosus. A higher incidence of chorioamnionitis, use of surfactant, lower weight and gestational age, sepsis, heart murmur, ventilatory support and worse oxygenation indices were observed in the neonates receiving treatment. The group with spontaneous closure had a smaller ductus arteriosus diameter, lower ductus arteriosus/weight ratio, and higher transductal flow velocity. CONCLUSION: Based on clinical and echocardiographic parameters, the neonates with spontaneous closure of the ductus arteriosus could be differentiated from those who required treatment.
format Online
Article
Text
id pubmed-4878590
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Instituto Israelita de Ensino e Pesquisa Albert Einstein
record_format MEDLINE/PubMed
spelling pubmed-48785902016-08-10 Clinical and echocardiographic characteristics associated with the evolution of the ductus arteriosus in the neonate with birth weight lower than 1,500g Visconti, Luiza Fortunato Morhy, Samira Saady Deutsch, Alice D'Agostini Tavares, Gláucia Maria Penha Wilberg, Tatiana Jardim Mussi Rossi, Felipe de Souza Einstein (Sao Paulo) Original Article OBJECTIVE: To identify clinical and echocardiographic parameters associated with the evolution of the ductus arteriosus in neonates with birth weight lower than 1,500g. METHODS: Retrospective study of 119 neonates in which clinical parameters (Prenatal: maternal age, risk of infection and chorioamnionitis, use of corticosteroid, mode of delivery and gestational age. Perinatal: weight, Apgar score, gender and birth weight/gestational age classification; Postnatal: use of surfactant, sepsis, fluid intake, heart murmur, heart rate, precordial movement and pulses, use of diuretics, oxygenation index, desaturation/apnea, ventilatory support, food intolerance, chest radiography, renal function, hemodynamic instability, and metabolic changes) and echocardiographic parameters (ductus arteriosus diameter, ductus arteriosus/weight ratio, left atrium/ aorta ratio, left ventricular diastolic diameter, and transductal flow direction, pattern and velocity) were analyzed. The clinical and echocardiographic parameters analyzed were considered statistically significant when p<0.05. RESULTS: In the 119 neonates, the incidence of patent ductus arteriosus was 61.3%; 56 received treatment (46 pharmacological and 10 surgical treatment), 11 had spontaneous closure, 4 died, and 2 were discharged with patent ductus arteriosus. A higher incidence of chorioamnionitis, use of surfactant, lower weight and gestational age, sepsis, heart murmur, ventilatory support and worse oxygenation indices were observed in the neonates receiving treatment. The group with spontaneous closure had a smaller ductus arteriosus diameter, lower ductus arteriosus/weight ratio, and higher transductal flow velocity. CONCLUSION: Based on clinical and echocardiographic parameters, the neonates with spontaneous closure of the ductus arteriosus could be differentiated from those who required treatment. Instituto Israelita de Ensino e Pesquisa Albert Einstein 2013 /pmc/articles/PMC4878590/ /pubmed/24136758 http://dx.doi.org/10.1590/S1679-45082013000300010 Text en http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Visconti, Luiza Fortunato
Morhy, Samira Saady
Deutsch, Alice D'Agostini
Tavares, Gláucia Maria Penha
Wilberg, Tatiana Jardim Mussi
Rossi, Felipe de Souza
Clinical and echocardiographic characteristics associated with the evolution of the ductus arteriosus in the neonate with birth weight lower than 1,500g
title Clinical and echocardiographic characteristics associated with the evolution of the ductus arteriosus in the neonate with birth weight lower than 1,500g
title_full Clinical and echocardiographic characteristics associated with the evolution of the ductus arteriosus in the neonate with birth weight lower than 1,500g
title_fullStr Clinical and echocardiographic characteristics associated with the evolution of the ductus arteriosus in the neonate with birth weight lower than 1,500g
title_full_unstemmed Clinical and echocardiographic characteristics associated with the evolution of the ductus arteriosus in the neonate with birth weight lower than 1,500g
title_short Clinical and echocardiographic characteristics associated with the evolution of the ductus arteriosus in the neonate with birth weight lower than 1,500g
title_sort clinical and echocardiographic characteristics associated with the evolution of the ductus arteriosus in the neonate with birth weight lower than 1,500g
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4878590/
https://www.ncbi.nlm.nih.gov/pubmed/24136758
http://dx.doi.org/10.1590/S1679-45082013000300010
work_keys_str_mv AT viscontiluizafortunato clinicalandechocardiographiccharacteristicsassociatedwiththeevolutionoftheductusarteriosusintheneonatewithbirthweightlowerthan1500g
AT morhysamirasaady clinicalandechocardiographiccharacteristicsassociatedwiththeevolutionoftheductusarteriosusintheneonatewithbirthweightlowerthan1500g
AT deutschalicedagostini clinicalandechocardiographiccharacteristicsassociatedwiththeevolutionoftheductusarteriosusintheneonatewithbirthweightlowerthan1500g
AT tavaresglauciamariapenha clinicalandechocardiographiccharacteristicsassociatedwiththeevolutionoftheductusarteriosusintheneonatewithbirthweightlowerthan1500g
AT wilbergtatianajardimmussi clinicalandechocardiographiccharacteristicsassociatedwiththeevolutionoftheductusarteriosusintheneonatewithbirthweightlowerthan1500g
AT rossifelipedesouza clinicalandechocardiographiccharacteristicsassociatedwiththeevolutionoftheductusarteriosusintheneonatewithbirthweightlowerthan1500g