Very late stent thrombosis with bare-metal stent: identifying severe stent malapposition and underexpansion by intravascular ultrasound

A 60-year-old man with a history of implantation of two bare-metal stents 2 years prior presented to the emergency department with new-onset chest pain. He has been regularly taking angiotensin-converting enzyme inhibitors, beta blockers and aspirin. Aspirin was suspended for 10 days prior to the cu...

Descripción completa

Detalles Bibliográficos
Autores principales: Caixeta, Adriano, Braga, Vanessa Cristina Salomon Palma, Mintz, Gary S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Instituto Israelita de Ensino e Pesquisa Albert Einstein 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4878597/
https://www.ncbi.nlm.nih.gov/pubmed/24136765
http://dx.doi.org/10.1590/S1679-45082013000300017
_version_ 1782433582432649216
author Caixeta, Adriano
Braga, Vanessa Cristina Salomon Palma
Mintz, Gary S
author_facet Caixeta, Adriano
Braga, Vanessa Cristina Salomon Palma
Mintz, Gary S
author_sort Caixeta, Adriano
collection PubMed
description A 60-year-old man with a history of implantation of two bare-metal stents 2 years prior presented to the emergency department with new-onset chest pain. He has been regularly taking angiotensin-converting enzyme inhibitors, beta blockers and aspirin. Aspirin was suspended for 10 days prior to the current hospitalization in order to perform surgery to remove a kidney tumor. He underwent coronary angiography, which revealed a right coronary artery with a distal intraluminal defect within the stents, suggesting thrombus. Intravascular ultrasound demonstrated a severe malapposition and underexpansion throughout the entire length of the stents containing thrombus. In this case, the mechanisms of very late stent thrombosis after bare-metal stent most likely were a combination of mechanical factors (severe stent undersizing during the index procedure) and pharmacological factors (aspirin discontinuation).
format Online
Article
Text
id pubmed-4878597
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Instituto Israelita de Ensino e Pesquisa Albert Einstein
record_format MEDLINE/PubMed
spelling pubmed-48785972016-08-10 Very late stent thrombosis with bare-metal stent: identifying severe stent malapposition and underexpansion by intravascular ultrasound Caixeta, Adriano Braga, Vanessa Cristina Salomon Palma Mintz, Gary S Einstein (Sao Paulo) Case Report A 60-year-old man with a history of implantation of two bare-metal stents 2 years prior presented to the emergency department with new-onset chest pain. He has been regularly taking angiotensin-converting enzyme inhibitors, beta blockers and aspirin. Aspirin was suspended for 10 days prior to the current hospitalization in order to perform surgery to remove a kidney tumor. He underwent coronary angiography, which revealed a right coronary artery with a distal intraluminal defect within the stents, suggesting thrombus. Intravascular ultrasound demonstrated a severe malapposition and underexpansion throughout the entire length of the stents containing thrombus. In this case, the mechanisms of very late stent thrombosis after bare-metal stent most likely were a combination of mechanical factors (severe stent undersizing during the index procedure) and pharmacological factors (aspirin discontinuation). Instituto Israelita de Ensino e Pesquisa Albert Einstein 2013 /pmc/articles/PMC4878597/ /pubmed/24136765 http://dx.doi.org/10.1590/S1679-45082013000300017 Text en http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Caixeta, Adriano
Braga, Vanessa Cristina Salomon Palma
Mintz, Gary S
Very late stent thrombosis with bare-metal stent: identifying severe stent malapposition and underexpansion by intravascular ultrasound
title Very late stent thrombosis with bare-metal stent: identifying severe stent malapposition and underexpansion by intravascular ultrasound
title_full Very late stent thrombosis with bare-metal stent: identifying severe stent malapposition and underexpansion by intravascular ultrasound
title_fullStr Very late stent thrombosis with bare-metal stent: identifying severe stent malapposition and underexpansion by intravascular ultrasound
title_full_unstemmed Very late stent thrombosis with bare-metal stent: identifying severe stent malapposition and underexpansion by intravascular ultrasound
title_short Very late stent thrombosis with bare-metal stent: identifying severe stent malapposition and underexpansion by intravascular ultrasound
title_sort very late stent thrombosis with bare-metal stent: identifying severe stent malapposition and underexpansion by intravascular ultrasound
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4878597/
https://www.ncbi.nlm.nih.gov/pubmed/24136765
http://dx.doi.org/10.1590/S1679-45082013000300017
work_keys_str_mv AT caixetaadriano verylatestentthrombosiswithbaremetalstentidentifyingseverestentmalappositionandunderexpansionbyintravascularultrasound
AT bragavanessacristinasalomonpalma verylatestentthrombosiswithbaremetalstentidentifyingseverestentmalappositionandunderexpansionbyintravascularultrasound
AT mintzgarys verylatestentthrombosiswithbaremetalstentidentifyingseverestentmalappositionandunderexpansionbyintravascularultrasound