Cargando…
Ferrous iron content of intravenous iron formulations
The observed biological differences in safety and efficacy of intravenous (IV) iron formulations are attributable to physicochemical differences. In addition to differences in carbohydrate shell, polarographic signatures due to ferric iron [Fe(III)] and ferrous iron [Fe(II)] differ among IV iron for...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Netherlands
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4879161/ https://www.ncbi.nlm.nih.gov/pubmed/26956439 http://dx.doi.org/10.1007/s10534-016-9923-7 |
_version_ | 1782433645458358272 |
---|---|
author | Gupta, Ajay Pratt, Raymond D. Crumbliss, Alvin L. |
author_facet | Gupta, Ajay Pratt, Raymond D. Crumbliss, Alvin L. |
author_sort | Gupta, Ajay |
collection | PubMed |
description | The observed biological differences in safety and efficacy of intravenous (IV) iron formulations are attributable to physicochemical differences. In addition to differences in carbohydrate shell, polarographic signatures due to ferric iron [Fe(III)] and ferrous iron [Fe(II)] differ among IV iron formulations. Intravenous iron contains Fe(II) and releases labile iron in the circulation. Fe(II) generates toxic free radicals and reactive oxygen species and binds to bacterial siderophores and other in vivo sequestering agents. To evaluate whether differences in Fe(II) content may account for some observed biological differences between IV iron formulations, samples from multiple lots of various IV iron formulations were dissolved in 12 M concentrated HCl to dissociate and release all iron and then diluted with water to achieve 0.1 M HCl concentration. Fe(II) was then directly measured using ferrozine reagent and ultraviolet spectroscopy at 562 nm. Total iron content was measured by adding an excess of ascorbic acid to reduce Fe(III) to Fe(II), and Fe(II) was then measured by ferrozine assay. The Fe(II) concentration as a proportion of total iron content [Fe(III) + Fe(II)] in different lots of IV iron formulations was as follows: iron gluconate, 1.4 and 1.8 %; ferumoxytol, 0.26 %; ferric carboxymaltose, 1.4 %; iron dextran, 0.8 %; and iron sucrose, 10.2, 15.5, and 11.0 % (average, 12.2 %). The average Fe(II) content in iron sucrose was, therefore, ≥7.5-fold higher than in the other IV iron formulations. Further studies are needed to investigate the relationship between Fe(II) content and increased risk of oxidative stress and infections with iron sucrose. |
format | Online Article Text |
id | pubmed-4879161 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Springer Netherlands |
record_format | MEDLINE/PubMed |
spelling | pubmed-48791612016-06-21 Ferrous iron content of intravenous iron formulations Gupta, Ajay Pratt, Raymond D. Crumbliss, Alvin L. Biometals Article The observed biological differences in safety and efficacy of intravenous (IV) iron formulations are attributable to physicochemical differences. In addition to differences in carbohydrate shell, polarographic signatures due to ferric iron [Fe(III)] and ferrous iron [Fe(II)] differ among IV iron formulations. Intravenous iron contains Fe(II) and releases labile iron in the circulation. Fe(II) generates toxic free radicals and reactive oxygen species and binds to bacterial siderophores and other in vivo sequestering agents. To evaluate whether differences in Fe(II) content may account for some observed biological differences between IV iron formulations, samples from multiple lots of various IV iron formulations were dissolved in 12 M concentrated HCl to dissociate and release all iron and then diluted with water to achieve 0.1 M HCl concentration. Fe(II) was then directly measured using ferrozine reagent and ultraviolet spectroscopy at 562 nm. Total iron content was measured by adding an excess of ascorbic acid to reduce Fe(III) to Fe(II), and Fe(II) was then measured by ferrozine assay. The Fe(II) concentration as a proportion of total iron content [Fe(III) + Fe(II)] in different lots of IV iron formulations was as follows: iron gluconate, 1.4 and 1.8 %; ferumoxytol, 0.26 %; ferric carboxymaltose, 1.4 %; iron dextran, 0.8 %; and iron sucrose, 10.2, 15.5, and 11.0 % (average, 12.2 %). The average Fe(II) content in iron sucrose was, therefore, ≥7.5-fold higher than in the other IV iron formulations. Further studies are needed to investigate the relationship between Fe(II) content and increased risk of oxidative stress and infections with iron sucrose. Springer Netherlands 2016-03-08 2016 /pmc/articles/PMC4879161/ /pubmed/26956439 http://dx.doi.org/10.1007/s10534-016-9923-7 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Article Gupta, Ajay Pratt, Raymond D. Crumbliss, Alvin L. Ferrous iron content of intravenous iron formulations |
title | Ferrous iron content of intravenous iron formulations |
title_full | Ferrous iron content of intravenous iron formulations |
title_fullStr | Ferrous iron content of intravenous iron formulations |
title_full_unstemmed | Ferrous iron content of intravenous iron formulations |
title_short | Ferrous iron content of intravenous iron formulations |
title_sort | ferrous iron content of intravenous iron formulations |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4879161/ https://www.ncbi.nlm.nih.gov/pubmed/26956439 http://dx.doi.org/10.1007/s10534-016-9923-7 |
work_keys_str_mv | AT guptaajay ferrousironcontentofintravenousironformulations AT prattraymondd ferrousironcontentofintravenousironformulations AT crumblissalvinl ferrousironcontentofintravenousironformulations |