Cargando…

Implantable collamer lens V4b and V4c for correction of high myopia

PURPOSE: To evaluate the visual outcome and intraocular pressure changes after Visian Implantable Collamer Lens (ICL) implantation V4b and V4c (with central hole) for correction of high myopia. METHODS: A prospective, consecutive, interventional comparative case series of V4b and V4c ICL implantatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Bhandari, Vipul, Karandikar, Smitha, Reddy, Jagdeesh K., Relekar, Kirti
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4881151/
https://www.ncbi.nlm.nih.gov/pubmed/27239582
http://dx.doi.org/10.1016/j.joco.2016.01.001
_version_ 1782433921361772544
author Bhandari, Vipul
Karandikar, Smitha
Reddy, Jagdeesh K.
Relekar, Kirti
author_facet Bhandari, Vipul
Karandikar, Smitha
Reddy, Jagdeesh K.
Relekar, Kirti
author_sort Bhandari, Vipul
collection PubMed
description PURPOSE: To evaluate the visual outcome and intraocular pressure changes after Visian Implantable Collamer Lens (ICL) implantation V4b and V4c (with central hole) for correction of high myopia. METHODS: A prospective, consecutive, interventional comparative case series of V4b and V4c ICL implantation was done in high myopic patients who were unsuitable for laser vision. The main outcome measures studied were uncorrected and corrected distant visual acuity (UDVA, CDVA), ICL vault, intraocular pressure (IOP), endothelial cell count (ECC), and development of subcapsular lens opacities. The patients were evaluated at postoperative 1,3,6, and 9 months. RESULTS: A total of 62 eyes of 32 patients (24.56 ± 4.8 years) underwent V4b ICL implantation (21 non-toric, 41 toric ICL-TICL) with intraoperative peripheral iridectomy (PI), and 10 eyes of 5 patients (26.13 ± 3.8 years) had implantation of V4c ICL (4 non-toric, 6 TICL). The mean preoperative manifest spherical equivalent (MSE) was −9.98 ± 2.8 D and −9.14 ± 2.4 D in the V4b and V4c groups, respectively, which reduced to postoperative values of −0.24 ± 1.3 D and −0.2 ± 1.18 D, respectively. At the end of 9 months follow-up, mean ECC loss was 6.4% and 6.1%, mean vault was 573.13 ± 241.13 μ, and 612 ± 251.14 μ, respectively, in the V4b and V4c groups. Anterior subcapsular opacities were present in 6.9% and 3.14% of eyes with V4b and V4c groups, respectively. Four eyes from V4b (9.75%) and 1 eye from V4c (16.66%) had rotation of more than 30° and required realignment surgery, which was done successfully. Two eyes (3.22%) with V4b ICL implantation had high postoperative IOP (>35 mm Hg) due to blocked PI and required Nd:Yag laser iridotomy, which was done with successful control of IOP. The safety indices were 1.11 and 1.14, and efficacy indices were 1.4 and 1.5 in the V4b and V4c groups, respectively, at the end of 9 months. CONCLUSION: ICL implantation is a safe and effective surgery for correction of high myopia. Implantation of ICL with a central hole showed negligible postoperative IOP fluctuations without a peripheral iridectomy.
format Online
Article
Text
id pubmed-4881151
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-48811512016-05-27 Implantable collamer lens V4b and V4c for correction of high myopia Bhandari, Vipul Karandikar, Smitha Reddy, Jagdeesh K. Relekar, Kirti J Curr Ophthalmol Article PURPOSE: To evaluate the visual outcome and intraocular pressure changes after Visian Implantable Collamer Lens (ICL) implantation V4b and V4c (with central hole) for correction of high myopia. METHODS: A prospective, consecutive, interventional comparative case series of V4b and V4c ICL implantation was done in high myopic patients who were unsuitable for laser vision. The main outcome measures studied were uncorrected and corrected distant visual acuity (UDVA, CDVA), ICL vault, intraocular pressure (IOP), endothelial cell count (ECC), and development of subcapsular lens opacities. The patients were evaluated at postoperative 1,3,6, and 9 months. RESULTS: A total of 62 eyes of 32 patients (24.56 ± 4.8 years) underwent V4b ICL implantation (21 non-toric, 41 toric ICL-TICL) with intraoperative peripheral iridectomy (PI), and 10 eyes of 5 patients (26.13 ± 3.8 years) had implantation of V4c ICL (4 non-toric, 6 TICL). The mean preoperative manifest spherical equivalent (MSE) was −9.98 ± 2.8 D and −9.14 ± 2.4 D in the V4b and V4c groups, respectively, which reduced to postoperative values of −0.24 ± 1.3 D and −0.2 ± 1.18 D, respectively. At the end of 9 months follow-up, mean ECC loss was 6.4% and 6.1%, mean vault was 573.13 ± 241.13 μ, and 612 ± 251.14 μ, respectively, in the V4b and V4c groups. Anterior subcapsular opacities were present in 6.9% and 3.14% of eyes with V4b and V4c groups, respectively. Four eyes from V4b (9.75%) and 1 eye from V4c (16.66%) had rotation of more than 30° and required realignment surgery, which was done successfully. Two eyes (3.22%) with V4b ICL implantation had high postoperative IOP (>35 mm Hg) due to blocked PI and required Nd:Yag laser iridotomy, which was done with successful control of IOP. The safety indices were 1.11 and 1.14, and efficacy indices were 1.4 and 1.5 in the V4b and V4c groups, respectively, at the end of 9 months. CONCLUSION: ICL implantation is a safe and effective surgery for correction of high myopia. Implantation of ICL with a central hole showed negligible postoperative IOP fluctuations without a peripheral iridectomy. Elsevier 2016-02-09 /pmc/articles/PMC4881151/ /pubmed/27239582 http://dx.doi.org/10.1016/j.joco.2016.01.001 Text en Copyright © 2016, Iranian Society of Ophthalmology. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Bhandari, Vipul
Karandikar, Smitha
Reddy, Jagdeesh K.
Relekar, Kirti
Implantable collamer lens V4b and V4c for correction of high myopia
title Implantable collamer lens V4b and V4c for correction of high myopia
title_full Implantable collamer lens V4b and V4c for correction of high myopia
title_fullStr Implantable collamer lens V4b and V4c for correction of high myopia
title_full_unstemmed Implantable collamer lens V4b and V4c for correction of high myopia
title_short Implantable collamer lens V4b and V4c for correction of high myopia
title_sort implantable collamer lens v4b and v4c for correction of high myopia
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4881151/
https://www.ncbi.nlm.nih.gov/pubmed/27239582
http://dx.doi.org/10.1016/j.joco.2016.01.001
work_keys_str_mv AT bhandarivipul implantablecollamerlensv4bandv4cforcorrectionofhighmyopia
AT karandikarsmitha implantablecollamerlensv4bandv4cforcorrectionofhighmyopia
AT reddyjagdeeshk implantablecollamerlensv4bandv4cforcorrectionofhighmyopia
AT relekarkirti implantablecollamerlensv4bandv4cforcorrectionofhighmyopia