Cargando…

Induced apnea enhances image quality and visualization of cardiopulmonary anatomic during contrastenhanced cardiac computerized tomographic angiography in children

OBJECTIVE: The purpose of our study was to determine the effect of induced apnea on quality of cardiopulmonary structures during computerized tomographic (CT) angiography images in children with congenital heart diseases. METHODS: Pediatric patients with congenital heart defects undergoing cardiac C...

Descripción completa

Detalles Bibliográficos
Autores principales: Chakravarthy, Murali, Sunilkumar, Gubbihalli, Pargaonkar, Sumant, Hosur, Rajathadri, Harivelam, Chidananda, Kavaraganahalli, Deepak, Srinivasan, Pradeep
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4881624/
https://www.ncbi.nlm.nih.gov/pubmed/25849686
http://dx.doi.org/10.4103/0971-9784.154471
_version_ 1782434000162258944
author Chakravarthy, Murali
Sunilkumar, Gubbihalli
Pargaonkar, Sumant
Hosur, Rajathadri
Harivelam, Chidananda
Kavaraganahalli, Deepak
Srinivasan, Pradeep
author_facet Chakravarthy, Murali
Sunilkumar, Gubbihalli
Pargaonkar, Sumant
Hosur, Rajathadri
Harivelam, Chidananda
Kavaraganahalli, Deepak
Srinivasan, Pradeep
author_sort Chakravarthy, Murali
collection PubMed
description OBJECTIVE: The purpose of our study was to determine the effect of induced apnea on quality of cardiopulmonary structures during computerized tomographic (CT) angiography images in children with congenital heart diseases. METHODS: Pediatric patients with congenital heart defects undergoing cardiac CT angiography at our facility in the past 3 years participated in this study. The earlier patients underwent cardiac CT angiography without induced apnea and while, later, apnea was induced in patients, which was followed by electrocardiogram gated cardiac CT angiography. General anesthesia was induced using sleep dose of intravenous propofol. After the initial check CT, on request by the radiologist, apnea was induced by the anesthesiologist by administering 1 mg/kg of intravenous suxamethonium. Soon after apnea ensued, the contrast was injected, and CT angiogram carried out. CT images in the “apnea group” were compared with those in “nonapnea group.” After the completion of the procedure, the patients were mask ventilated with 100% oxygen till the spontaneous ventilation was restored. RESULTS: We studied 46 patients, of whom 36 with apnea and yet another 10 without. The quality of the image, visualization of structures such as cardiac wall, outflow tracts, lung field, aortopulmonary shunts, and coronary arteries were analyzed and subjected to statistical analysis (Mann–Whitney U, Fischer's exact test and Pearson's Chi-square test). In the induced apnea group, overall image quality was considered excellent in 89% (n = 33) of the studies, while in the “no apnea group,” only 30% of studies were excellent. Absent or minimal motion artifacts were seen in a majority of the studies in apnea group (94%). In the nonapnea group, the respiratory and body motion artifacts were severe in 50%, moderate in 30%, and minimal in 20%, but they were significantly lesser in the apnea group. All the studied parameters were statistically significant in the apnea group in contrast to nonapnea group (P < 0.000). CONCLUSION: The image quality of cardiac CT angiography greatly improves, and motion artifact significantly decreases with the use of induced apnea in pediatrics patients being evaluated for congenital heart disease. This technique poses no additional morbidity of significance.
format Online
Article
Text
id pubmed-4881624
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-48816242016-06-16 Induced apnea enhances image quality and visualization of cardiopulmonary anatomic during contrastenhanced cardiac computerized tomographic angiography in children Chakravarthy, Murali Sunilkumar, Gubbihalli Pargaonkar, Sumant Hosur, Rajathadri Harivelam, Chidananda Kavaraganahalli, Deepak Srinivasan, Pradeep Ann Card Anaesth Original Article OBJECTIVE: The purpose of our study was to determine the effect of induced apnea on quality of cardiopulmonary structures during computerized tomographic (CT) angiography images in children with congenital heart diseases. METHODS: Pediatric patients with congenital heart defects undergoing cardiac CT angiography at our facility in the past 3 years participated in this study. The earlier patients underwent cardiac CT angiography without induced apnea and while, later, apnea was induced in patients, which was followed by electrocardiogram gated cardiac CT angiography. General anesthesia was induced using sleep dose of intravenous propofol. After the initial check CT, on request by the radiologist, apnea was induced by the anesthesiologist by administering 1 mg/kg of intravenous suxamethonium. Soon after apnea ensued, the contrast was injected, and CT angiogram carried out. CT images in the “apnea group” were compared with those in “nonapnea group.” After the completion of the procedure, the patients were mask ventilated with 100% oxygen till the spontaneous ventilation was restored. RESULTS: We studied 46 patients, of whom 36 with apnea and yet another 10 without. The quality of the image, visualization of structures such as cardiac wall, outflow tracts, lung field, aortopulmonary shunts, and coronary arteries were analyzed and subjected to statistical analysis (Mann–Whitney U, Fischer's exact test and Pearson's Chi-square test). In the induced apnea group, overall image quality was considered excellent in 89% (n = 33) of the studies, while in the “no apnea group,” only 30% of studies were excellent. Absent or minimal motion artifacts were seen in a majority of the studies in apnea group (94%). In the nonapnea group, the respiratory and body motion artifacts were severe in 50%, moderate in 30%, and minimal in 20%, but they were significantly lesser in the apnea group. All the studied parameters were statistically significant in the apnea group in contrast to nonapnea group (P < 0.000). CONCLUSION: The image quality of cardiac CT angiography greatly improves, and motion artifact significantly decreases with the use of induced apnea in pediatrics patients being evaluated for congenital heart disease. This technique poses no additional morbidity of significance. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4881624/ /pubmed/25849686 http://dx.doi.org/10.4103/0971-9784.154471 Text en Copyright: © 2015 Annals of Cardiac Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Chakravarthy, Murali
Sunilkumar, Gubbihalli
Pargaonkar, Sumant
Hosur, Rajathadri
Harivelam, Chidananda
Kavaraganahalli, Deepak
Srinivasan, Pradeep
Induced apnea enhances image quality and visualization of cardiopulmonary anatomic during contrastenhanced cardiac computerized tomographic angiography in children
title Induced apnea enhances image quality and visualization of cardiopulmonary anatomic during contrastenhanced cardiac computerized tomographic angiography in children
title_full Induced apnea enhances image quality and visualization of cardiopulmonary anatomic during contrastenhanced cardiac computerized tomographic angiography in children
title_fullStr Induced apnea enhances image quality and visualization of cardiopulmonary anatomic during contrastenhanced cardiac computerized tomographic angiography in children
title_full_unstemmed Induced apnea enhances image quality and visualization of cardiopulmonary anatomic during contrastenhanced cardiac computerized tomographic angiography in children
title_short Induced apnea enhances image quality and visualization of cardiopulmonary anatomic during contrastenhanced cardiac computerized tomographic angiography in children
title_sort induced apnea enhances image quality and visualization of cardiopulmonary anatomic during contrastenhanced cardiac computerized tomographic angiography in children
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4881624/
https://www.ncbi.nlm.nih.gov/pubmed/25849686
http://dx.doi.org/10.4103/0971-9784.154471
work_keys_str_mv AT chakravarthymurali inducedapneaenhancesimagequalityandvisualizationofcardiopulmonaryanatomicduringcontrastenhancedcardiaccomputerizedtomographicangiographyinchildren
AT sunilkumargubbihalli inducedapneaenhancesimagequalityandvisualizationofcardiopulmonaryanatomicduringcontrastenhancedcardiaccomputerizedtomographicangiographyinchildren
AT pargaonkarsumant inducedapneaenhancesimagequalityandvisualizationofcardiopulmonaryanatomicduringcontrastenhancedcardiaccomputerizedtomographicangiographyinchildren
AT hosurrajathadri inducedapneaenhancesimagequalityandvisualizationofcardiopulmonaryanatomicduringcontrastenhancedcardiaccomputerizedtomographicangiographyinchildren
AT harivelamchidananda inducedapneaenhancesimagequalityandvisualizationofcardiopulmonaryanatomicduringcontrastenhancedcardiaccomputerizedtomographicangiographyinchildren
AT kavaraganahallideepak inducedapneaenhancesimagequalityandvisualizationofcardiopulmonaryanatomicduringcontrastenhancedcardiaccomputerizedtomographicangiographyinchildren
AT srinivasanpradeep inducedapneaenhancesimagequalityandvisualizationofcardiopulmonaryanatomicduringcontrastenhancedcardiaccomputerizedtomographicangiographyinchildren