BACKGROUND: Transapical off-pump mitral valve intervention with neochord implantation for degenerative mitral valve disease have been recently introduced in the surgical practice. The procedure is performed under 2D-3D transesophageal echocardiography guidance. METHODS: The use of 3D real-time trans...

Descripción completa

Detalles Bibliográficos
Autores principales: Demetrio, Pittarello, Andrea, Colli, Gianclaudio, Falasco, Antonio, Marcassa, Gino, Gerosa, Carlo, Ori
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4881639/
https://www.ncbi.nlm.nih.gov/pubmed/25849688
http://dx.doi.org/10.4103/0971-9784.154473
_version_ 1782434003297501184
author Demetrio, Pittarello
Andrea, Colli
Gianclaudio, Falasco
Antonio, Marcassa
Gino, Gerosa
Carlo, Ori
author_facet Demetrio, Pittarello
Andrea, Colli
Gianclaudio, Falasco
Antonio, Marcassa
Gino, Gerosa
Carlo, Ori
author_sort Demetrio, Pittarello
collection PubMed
description BACKGROUND: Transapical off-pump mitral valve intervention with neochord implantation for degenerative mitral valve disease have been recently introduced in the surgical practice. The procedure is performed under 2D-3D transesophageal echocardiography guidance. METHODS: The use of 3D real-time transesophageal echocardiography provides more accurate information than 2D echocardiography only in all the steps of the procedure. In particular 3D echocardiography is mandatory for preoperative assessment of the morphology of the valve, for correct positioning of the neochord on the diseased segment, for the final tensioning of the chordae and for the final evaluation of the surgical result. RESULT AND CONCLUSION: This article is to outline the technical aspects of the transesophageal echocardiography guidance of the NeoChord procedure showing that the procedure can be performed only with a close and continuous interaction between the anesthesiologist and the cardiac surgeon.
format Online
Article
Text
id pubmed-4881639
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-48816392016-06-16 Transesophageal echocardiography in NeoChord procedure Demetrio, Pittarello Andrea, Colli Gianclaudio, Falasco Antonio, Marcassa Gino, Gerosa Carlo, Ori Ann Card Anaesth Original Article BACKGROUND: Transapical off-pump mitral valve intervention with neochord implantation for degenerative mitral valve disease have been recently introduced in the surgical practice. The procedure is performed under 2D-3D transesophageal echocardiography guidance. METHODS: The use of 3D real-time transesophageal echocardiography provides more accurate information than 2D echocardiography only in all the steps of the procedure. In particular 3D echocardiography is mandatory for preoperative assessment of the morphology of the valve, for correct positioning of the neochord on the diseased segment, for the final tensioning of the chordae and for the final evaluation of the surgical result. RESULT AND CONCLUSION: This article is to outline the technical aspects of the transesophageal echocardiography guidance of the NeoChord procedure showing that the procedure can be performed only with a close and continuous interaction between the anesthesiologist and the cardiac surgeon. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4881639/ /pubmed/25849688 http://dx.doi.org/10.4103/0971-9784.154473 Text en Copyright: © 2015 Annals of Cardiac Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Demetrio, Pittarello
Andrea, Colli
Gianclaudio, Falasco
Antonio, Marcassa
Gino, Gerosa
Carlo, Ori
Transesophageal echocardiography in NeoChord procedure
title Transesophageal echocardiography in NeoChord procedure
title_full Transesophageal echocardiography in NeoChord procedure
title_fullStr Transesophageal echocardiography in NeoChord procedure
title_full_unstemmed Transesophageal echocardiography in NeoChord procedure
title_short Transesophageal echocardiography in NeoChord procedure
title_sort transesophageal echocardiography in neochord procedure
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4881639/
https://www.ncbi.nlm.nih.gov/pubmed/25849688
http://dx.doi.org/10.4103/0971-9784.154473
work_keys_str_mv AT demetriopittarello transesophagealechocardiographyinneochordprocedure
AT andreacolli transesophagealechocardiographyinneochordprocedure
AT gianclaudiofalasco transesophagealechocardiographyinneochordprocedure
AT antoniomarcassa transesophagealechocardiographyinneochordprocedure
AT ginogerosa transesophagealechocardiographyinneochordprocedure
AT carloori transesophagealechocardiographyinneochordprocedure