Pressure bandage over venous conduit harvesting site causing compartment syndrome in a patient with intra-aortic balloon pump: An unusual cause
Intra Aortic Balloon Pump (IABP) is conventionally used to support coronary perfusion and weaning from cardiopulmonary bypass. IABP in situ has its own share of complications. We present a case where a patient on IABP support who had reduced peripheral pulsations of the ipsilateral limb and was init...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4881702/ https://www.ncbi.nlm.nih.gov/pubmed/26139763 http://dx.doi.org/10.4103/0971-9784.159823 |
Sumario: | Intra Aortic Balloon Pump (IABP) is conventionally used to support coronary perfusion and weaning from cardiopulmonary bypass. IABP in situ has its own share of complications. We present a case where a patient on IABP support who had reduced peripheral pulsations of the ipsilateral limb and was initially misdiagnosed as IABP catheter associated thromboembolism. A negative embolectomy ruled out the same. Further looking for the cause of reduction of ipsilateral pulses it was found that the tight compressive bandage at saphenous vein conduit harvesting site had led to development of compartment syndrome (CS). |
---|