Cargando…
Pressure bandage over venous conduit harvesting site causing compartment syndrome in a patient with intra-aortic balloon pump: An unusual cause
Intra Aortic Balloon Pump (IABP) is conventionally used to support coronary perfusion and weaning from cardiopulmonary bypass. IABP in situ has its own share of complications. We present a case where a patient on IABP support who had reduced peripheral pulsations of the ipsilateral limb and was init...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4881702/ https://www.ncbi.nlm.nih.gov/pubmed/26139763 http://dx.doi.org/10.4103/0971-9784.159823 |
_version_ | 1782434017531920384 |
---|---|
author | Rastogi, Amit Haldar, Rudrashish Majumdar, Gauranga Pahade, Akhilesh Singh, Prabhat. K. |
author_facet | Rastogi, Amit Haldar, Rudrashish Majumdar, Gauranga Pahade, Akhilesh Singh, Prabhat. K. |
author_sort | Rastogi, Amit |
collection | PubMed |
description | Intra Aortic Balloon Pump (IABP) is conventionally used to support coronary perfusion and weaning from cardiopulmonary bypass. IABP in situ has its own share of complications. We present a case where a patient on IABP support who had reduced peripheral pulsations of the ipsilateral limb and was initially misdiagnosed as IABP catheter associated thromboembolism. A negative embolectomy ruled out the same. Further looking for the cause of reduction of ipsilateral pulses it was found that the tight compressive bandage at saphenous vein conduit harvesting site had led to development of compartment syndrome (CS). |
format | Online Article Text |
id | pubmed-4881702 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-48817022016-06-16 Pressure bandage over venous conduit harvesting site causing compartment syndrome in a patient with intra-aortic balloon pump: An unusual cause Rastogi, Amit Haldar, Rudrashish Majumdar, Gauranga Pahade, Akhilesh Singh, Prabhat. K. Ann Card Anaesth Case Report Intra Aortic Balloon Pump (IABP) is conventionally used to support coronary perfusion and weaning from cardiopulmonary bypass. IABP in situ has its own share of complications. We present a case where a patient on IABP support who had reduced peripheral pulsations of the ipsilateral limb and was initially misdiagnosed as IABP catheter associated thromboembolism. A negative embolectomy ruled out the same. Further looking for the cause of reduction of ipsilateral pulses it was found that the tight compressive bandage at saphenous vein conduit harvesting site had led to development of compartment syndrome (CS). Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4881702/ /pubmed/26139763 http://dx.doi.org/10.4103/0971-9784.159823 Text en Copyright: © 2015 Annals of Cardiac Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Case Report Rastogi, Amit Haldar, Rudrashish Majumdar, Gauranga Pahade, Akhilesh Singh, Prabhat. K. Pressure bandage over venous conduit harvesting site causing compartment syndrome in a patient with intra-aortic balloon pump: An unusual cause |
title | Pressure bandage over venous conduit harvesting site causing compartment syndrome in a patient with intra-aortic balloon pump: An unusual cause |
title_full | Pressure bandage over venous conduit harvesting site causing compartment syndrome in a patient with intra-aortic balloon pump: An unusual cause |
title_fullStr | Pressure bandage over venous conduit harvesting site causing compartment syndrome in a patient with intra-aortic balloon pump: An unusual cause |
title_full_unstemmed | Pressure bandage over venous conduit harvesting site causing compartment syndrome in a patient with intra-aortic balloon pump: An unusual cause |
title_short | Pressure bandage over venous conduit harvesting site causing compartment syndrome in a patient with intra-aortic balloon pump: An unusual cause |
title_sort | pressure bandage over venous conduit harvesting site causing compartment syndrome in a patient with intra-aortic balloon pump: an unusual cause |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4881702/ https://www.ncbi.nlm.nih.gov/pubmed/26139763 http://dx.doi.org/10.4103/0971-9784.159823 |
work_keys_str_mv | AT rastogiamit pressurebandageovervenousconduitharvestingsitecausingcompartmentsyndromeinapatientwithintraaorticballoonpumpanunusualcause AT haldarrudrashish pressurebandageovervenousconduitharvestingsitecausingcompartmentsyndromeinapatientwithintraaorticballoonpumpanunusualcause AT majumdargauranga pressurebandageovervenousconduitharvestingsitecausingcompartmentsyndromeinapatientwithintraaorticballoonpumpanunusualcause AT pahadeakhilesh pressurebandageovervenousconduitharvestingsitecausingcompartmentsyndromeinapatientwithintraaorticballoonpumpanunusualcause AT singhprabhatk pressurebandageovervenousconduitharvestingsitecausingcompartmentsyndromeinapatientwithintraaorticballoonpumpanunusualcause |