Comparison of Titanium vs. Polycel Total Ossicular Replacement Prosthesis

INTRODUCTION: Even though modern technology progresses so rapidly, annals of otology are replete with so many challenging article, which often compare various types of prosthesis. Since there has not been a prospective randomized clinical trial study which compares the hearing result of total ossicu...

Descripción completa

Detalles Bibliográficos
Autores principales: Faramarzi, Mohammad, Jahangiri, Reza, Roosta, Sareh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Mashhad University of Medical Sciences 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4881876/
https://www.ncbi.nlm.nih.gov/pubmed/27280094
_version_ 1782434030478688256
author Faramarzi, Mohammad
Jahangiri, Reza
Roosta, Sareh
author_facet Faramarzi, Mohammad
Jahangiri, Reza
Roosta, Sareh
author_sort Faramarzi, Mohammad
collection PubMed
description INTRODUCTION: Even though modern technology progresses so rapidly, annals of otology are replete with so many challenging article, which often compare various types of prosthesis. Since there has not been a prospective randomized clinical trial study which compares the hearing result of total ossicular replacement prosthesis made of Titanium with omega connector and Polycel in the literature, we decided to perform a study encompassing this issue. MATERIALS AND METHODS: 105 patients, who were in the 2nd stage of their operation and who needed total ossicular replacement prosthesis, were included in this prospective single blind randomized clinical trial study. Patients were classified in two groups: titanium Kurz (TTP™ -Vario system, Kurz GmbH, Dusslingen, Germany) with omega connector and Polycel (Sheehy Plastipore Polycel, Medtronic Xomed Inc). The duration of the follow up was 6-12 months. In order to evaluate hearing results, pure tone audiometric in 0.5, 1, 2, and 4 kHz were checked. In addition, speech reception threshold was recorded. A successful surgery was defined as having a postoperative air–bone gap within 20 dB. RESULTS: We accomplished successful hearing in 64.4% of patients with titanium and 65% of patients with a Polycel prosthesis.Improvement in speech reception threshold was 11.5 dB in the titanium group and 13 dB in the Polycel group. In other words, there was no significant difference between the two groups. In addition, air-bone gap improvement after ossiculoplasty was 11.2 dB in the patients with a titanium prosthesis and 12.4 dB in the Polycel group. In fact, the difference was not significant. CONCLUSION: We found that both the titanium and the Polycel prosthesis improve speech reception threshold and air-bone gap closure in a similar manner.
format Online
Article
Text
id pubmed-4881876
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Mashhad University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-48818762016-06-08 Comparison of Titanium vs. Polycel Total Ossicular Replacement Prosthesis Faramarzi, Mohammad Jahangiri, Reza Roosta, Sareh Iran J Otorhinolaryngol Original Article INTRODUCTION: Even though modern technology progresses so rapidly, annals of otology are replete with so many challenging article, which often compare various types of prosthesis. Since there has not been a prospective randomized clinical trial study which compares the hearing result of total ossicular replacement prosthesis made of Titanium with omega connector and Polycel in the literature, we decided to perform a study encompassing this issue. MATERIALS AND METHODS: 105 patients, who were in the 2nd stage of their operation and who needed total ossicular replacement prosthesis, were included in this prospective single blind randomized clinical trial study. Patients were classified in two groups: titanium Kurz (TTP™ -Vario system, Kurz GmbH, Dusslingen, Germany) with omega connector and Polycel (Sheehy Plastipore Polycel, Medtronic Xomed Inc). The duration of the follow up was 6-12 months. In order to evaluate hearing results, pure tone audiometric in 0.5, 1, 2, and 4 kHz were checked. In addition, speech reception threshold was recorded. A successful surgery was defined as having a postoperative air–bone gap within 20 dB. RESULTS: We accomplished successful hearing in 64.4% of patients with titanium and 65% of patients with a Polycel prosthesis.Improvement in speech reception threshold was 11.5 dB in the titanium group and 13 dB in the Polycel group. In other words, there was no significant difference between the two groups. In addition, air-bone gap improvement after ossiculoplasty was 11.2 dB in the patients with a titanium prosthesis and 12.4 dB in the Polycel group. In fact, the difference was not significant. CONCLUSION: We found that both the titanium and the Polycel prosthesis improve speech reception threshold and air-bone gap closure in a similar manner. Mashhad University of Medical Sciences 2016-03 /pmc/articles/PMC4881876/ /pubmed/27280094 Text en This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Faramarzi, Mohammad
Jahangiri, Reza
Roosta, Sareh
Comparison of Titanium vs. Polycel Total Ossicular Replacement Prosthesis
title Comparison of Titanium vs. Polycel Total Ossicular Replacement Prosthesis
title_full Comparison of Titanium vs. Polycel Total Ossicular Replacement Prosthesis
title_fullStr Comparison of Titanium vs. Polycel Total Ossicular Replacement Prosthesis
title_full_unstemmed Comparison of Titanium vs. Polycel Total Ossicular Replacement Prosthesis
title_short Comparison of Titanium vs. Polycel Total Ossicular Replacement Prosthesis
title_sort comparison of titanium vs. polycel total ossicular replacement prosthesis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4881876/
https://www.ncbi.nlm.nih.gov/pubmed/27280094
work_keys_str_mv AT faramarzimohammad comparisonoftitaniumvspolyceltotalossicularreplacementprosthesis
AT jahangirireza comparisonoftitaniumvspolyceltotalossicularreplacementprosthesis
AT roostasareh comparisonoftitaniumvspolyceltotalossicularreplacementprosthesis