Cargando…

The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses

This study investigates the impact of the subcutaneous fat layer (SFL) thickness on localized electrical impedance myography (EIM), as well as the effects of different current electrodes, varying in distance and direction, on EIM output. Twenty-three healthy subjects underwent localized multi-freque...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Le, Li, Xiaoyan, Hu, Huijing, Shin, Henry, Zhou, Ping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4882074/
https://www.ncbi.nlm.nih.gov/pubmed/27227876
http://dx.doi.org/10.1371/journal.pone.0156154
_version_ 1782434075166900224
author Li, Le
Li, Xiaoyan
Hu, Huijing
Shin, Henry
Zhou, Ping
author_facet Li, Le
Li, Xiaoyan
Hu, Huijing
Shin, Henry
Zhou, Ping
author_sort Li, Le
collection PubMed
description This study investigates the impact of the subcutaneous fat layer (SFL) thickness on localized electrical impedance myography (EIM), as well as the effects of different current electrodes, varying in distance and direction, on EIM output. Twenty-three healthy subjects underwent localized multi-frequency EIM on their biceps brachii muscles with a hand-held electrode array. The EIM measurements were recorded under three different configurations: wide (or outer) longitudinal configuration 6.8 cm, narrow (or inner) longitudinal configuration 4.5 cm, and narrow transverse configuration 4.5 cm. Ultrasound was applied to measure the SFL thickness. Coefficients of determination (R(2)) of three EIM variables (resistance, reactance, and phase) and SFL thickness were calculated. For the longitudinal configuration, the wide distance could reduce the effects of the subcutaneous fat when compared with the narrow distance, but a significant correlation still remained for all three EIM parameters. However, there was no significant correlation between SFL thickness and reactance in the transverse configuration (R(2) = 0.0294, p = 0.434). Utilizing a ratio of 50kHz/100kHz phase was found to be able to help reduce the correlation with SFL thickness for all the three configurations. The findings indicate that the appropriate selection of the current electrode distance, direction and the multi-frequency phase ratio can reduce the impact of subcutaneous fat on EIM. These settings should be evaluated for future clinical studies using hand-held localized arrays to perform EIM.
format Online
Article
Text
id pubmed-4882074
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-48820742016-06-10 The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses Li, Le Li, Xiaoyan Hu, Huijing Shin, Henry Zhou, Ping PLoS One Research Article This study investigates the impact of the subcutaneous fat layer (SFL) thickness on localized electrical impedance myography (EIM), as well as the effects of different current electrodes, varying in distance and direction, on EIM output. Twenty-three healthy subjects underwent localized multi-frequency EIM on their biceps brachii muscles with a hand-held electrode array. The EIM measurements were recorded under three different configurations: wide (or outer) longitudinal configuration 6.8 cm, narrow (or inner) longitudinal configuration 4.5 cm, and narrow transverse configuration 4.5 cm. Ultrasound was applied to measure the SFL thickness. Coefficients of determination (R(2)) of three EIM variables (resistance, reactance, and phase) and SFL thickness were calculated. For the longitudinal configuration, the wide distance could reduce the effects of the subcutaneous fat when compared with the narrow distance, but a significant correlation still remained for all three EIM parameters. However, there was no significant correlation between SFL thickness and reactance in the transverse configuration (R(2) = 0.0294, p = 0.434). Utilizing a ratio of 50kHz/100kHz phase was found to be able to help reduce the correlation with SFL thickness for all the three configurations. The findings indicate that the appropriate selection of the current electrode distance, direction and the multi-frequency phase ratio can reduce the impact of subcutaneous fat on EIM. These settings should be evaluated for future clinical studies using hand-held localized arrays to perform EIM. Public Library of Science 2016-05-26 /pmc/articles/PMC4882074/ /pubmed/27227876 http://dx.doi.org/10.1371/journal.pone.0156154 Text en © 2016 Li et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Li, Le
Li, Xiaoyan
Hu, Huijing
Shin, Henry
Zhou, Ping
The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses
title The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses
title_full The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses
title_fullStr The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses
title_full_unstemmed The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses
title_short The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses
title_sort effect of subcutaneous fat on electrical impedance myography: electrode configuration and multi-frequency analyses
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4882074/
https://www.ncbi.nlm.nih.gov/pubmed/27227876
http://dx.doi.org/10.1371/journal.pone.0156154
work_keys_str_mv AT lile theeffectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses
AT lixiaoyan theeffectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses
AT huhuijing theeffectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses
AT shinhenry theeffectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses
AT zhouping theeffectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses
AT lile effectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses
AT lixiaoyan effectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses
AT huhuijing effectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses
AT shinhenry effectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses
AT zhouping effectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses