The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses
This study investigates the impact of the subcutaneous fat layer (SFL) thickness on localized electrical impedance myography (EIM), as well as the effects of different current electrodes, varying in distance and direction, on EIM output. Twenty-three healthy subjects underwent localized multi-freque...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4882074/ https://www.ncbi.nlm.nih.gov/pubmed/27227876 http://dx.doi.org/10.1371/journal.pone.0156154 |
_version_ | 1782434075166900224 |
---|---|
author | Li, Le Li, Xiaoyan Hu, Huijing Shin, Henry Zhou, Ping |
author_facet | Li, Le Li, Xiaoyan Hu, Huijing Shin, Henry Zhou, Ping |
author_sort | Li, Le |
collection | PubMed |
description | This study investigates the impact of the subcutaneous fat layer (SFL) thickness on localized electrical impedance myography (EIM), as well as the effects of different current electrodes, varying in distance and direction, on EIM output. Twenty-three healthy subjects underwent localized multi-frequency EIM on their biceps brachii muscles with a hand-held electrode array. The EIM measurements were recorded under three different configurations: wide (or outer) longitudinal configuration 6.8 cm, narrow (or inner) longitudinal configuration 4.5 cm, and narrow transverse configuration 4.5 cm. Ultrasound was applied to measure the SFL thickness. Coefficients of determination (R(2)) of three EIM variables (resistance, reactance, and phase) and SFL thickness were calculated. For the longitudinal configuration, the wide distance could reduce the effects of the subcutaneous fat when compared with the narrow distance, but a significant correlation still remained for all three EIM parameters. However, there was no significant correlation between SFL thickness and reactance in the transverse configuration (R(2) = 0.0294, p = 0.434). Utilizing a ratio of 50kHz/100kHz phase was found to be able to help reduce the correlation with SFL thickness for all the three configurations. The findings indicate that the appropriate selection of the current electrode distance, direction and the multi-frequency phase ratio can reduce the impact of subcutaneous fat on EIM. These settings should be evaluated for future clinical studies using hand-held localized arrays to perform EIM. |
format | Online Article Text |
id | pubmed-4882074 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-48820742016-06-10 The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses Li, Le Li, Xiaoyan Hu, Huijing Shin, Henry Zhou, Ping PLoS One Research Article This study investigates the impact of the subcutaneous fat layer (SFL) thickness on localized electrical impedance myography (EIM), as well as the effects of different current electrodes, varying in distance and direction, on EIM output. Twenty-three healthy subjects underwent localized multi-frequency EIM on their biceps brachii muscles with a hand-held electrode array. The EIM measurements were recorded under three different configurations: wide (or outer) longitudinal configuration 6.8 cm, narrow (or inner) longitudinal configuration 4.5 cm, and narrow transverse configuration 4.5 cm. Ultrasound was applied to measure the SFL thickness. Coefficients of determination (R(2)) of three EIM variables (resistance, reactance, and phase) and SFL thickness were calculated. For the longitudinal configuration, the wide distance could reduce the effects of the subcutaneous fat when compared with the narrow distance, but a significant correlation still remained for all three EIM parameters. However, there was no significant correlation between SFL thickness and reactance in the transverse configuration (R(2) = 0.0294, p = 0.434). Utilizing a ratio of 50kHz/100kHz phase was found to be able to help reduce the correlation with SFL thickness for all the three configurations. The findings indicate that the appropriate selection of the current electrode distance, direction and the multi-frequency phase ratio can reduce the impact of subcutaneous fat on EIM. These settings should be evaluated for future clinical studies using hand-held localized arrays to perform EIM. Public Library of Science 2016-05-26 /pmc/articles/PMC4882074/ /pubmed/27227876 http://dx.doi.org/10.1371/journal.pone.0156154 Text en © 2016 Li et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Li, Le Li, Xiaoyan Hu, Huijing Shin, Henry Zhou, Ping The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses |
title | The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses |
title_full | The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses |
title_fullStr | The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses |
title_full_unstemmed | The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses |
title_short | The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses |
title_sort | effect of subcutaneous fat on electrical impedance myography: electrode configuration and multi-frequency analyses |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4882074/ https://www.ncbi.nlm.nih.gov/pubmed/27227876 http://dx.doi.org/10.1371/journal.pone.0156154 |
work_keys_str_mv | AT lile theeffectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses AT lixiaoyan theeffectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses AT huhuijing theeffectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses AT shinhenry theeffectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses AT zhouping theeffectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses AT lile effectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses AT lixiaoyan effectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses AT huhuijing effectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses AT shinhenry effectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses AT zhouping effectofsubcutaneousfatonelectricalimpedancemyographyelectrodeconfigurationandmultifrequencyanalyses |