Cargando…

Structural mechanical properties of radiation-sterilized human Bone-Tendon-Bone grafts preserved by different methods

To avoid the risk of infectious disease transmission from donor to recipient, allografts should be terminally sterilized. In the previous paper (Kaminski et al. in Cell Tissue Bank 10:215–219, 2009) we presented the effect of various methods of preservation (deep fresh freezing, glycerolization, lyo...

Descripción completa

Detalles Bibliográficos
Autores principales: Gut, Grzegorz, Marowska, Joanna, Jastrzebska, Anna, Olender, Ewa, Kamiński, Artur
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4882344/
https://www.ncbi.nlm.nih.gov/pubmed/26679928
http://dx.doi.org/10.1007/s10561-015-9538-1
_version_ 1782434099970965504
author Gut, Grzegorz
Marowska, Joanna
Jastrzebska, Anna
Olender, Ewa
Kamiński, Artur
author_facet Gut, Grzegorz
Marowska, Joanna
Jastrzebska, Anna
Olender, Ewa
Kamiński, Artur
author_sort Gut, Grzegorz
collection PubMed
description To avoid the risk of infectious disease transmission from donor to recipient, allografts should be terminally sterilized. In the previous paper (Kaminski et al. in Cell Tissue Bank 10:215–219, 2009) we presented the effect of various methods of preservation (deep fresh freezing, glycerolization, lyophilization), followed by irradiation with different doses of electron beam (EB), on material (intrinsic) mechanical properties of human patellar tendons cut out as for anterior cruciate ligament reconstruction, obtained in failure tensile test. As structural mechanical properties are equally important to predict the behaviour of the graft as a whole functional unit, the purpose of the present paper was to show the results for failure load and elongation, obtained in the same experiment. Paired Bone-Tendon-Bone grafts (BTB) were prepared from cadaveric human patella tendons with both patellar and tibial attachments. They were preserved by deep freezing, glycerolization or lyophilization and subsequently EB-irradiated with the doses of 25, 35, 50 or 100 kGy (fresh-frozen grafts) or a single dose of 35 kGy (glycerolized and lyophilized grafts). Each experimental (irradiated) group was provided with control (non-irradiated), donor-matched group. The specimens from all groups were subjected to mechanical failure tensile test with the use of Instron system in order to measure their structural properties (failure load and elongation). All lyophilized grafts were rehydrated before mechanical testing. In our study we did not observe significant deterioration of structural mechanical properties of BTB grafts processed by fresh-freezing and then terminal sterilized with growing doses of EB up to 100 kGy. In contrast, BTB grafts processed by glycerolization or lyophilization and irradiated with 35 kGy showed significant decrease of failure load. Obtained results suggest that deep-frozen irradiated grafts retain their initial mechanical properties to an extent which does not exclude their clinical application. However, biomechanical investigations constitute only the first step to evaluate the potential clinical usefulness of such allografts and further extensive in vivo studies are needed.
format Online
Article
Text
id pubmed-4882344
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-48823442016-06-21 Structural mechanical properties of radiation-sterilized human Bone-Tendon-Bone grafts preserved by different methods Gut, Grzegorz Marowska, Joanna Jastrzebska, Anna Olender, Ewa Kamiński, Artur Cell Tissue Bank Original Paper To avoid the risk of infectious disease transmission from donor to recipient, allografts should be terminally sterilized. In the previous paper (Kaminski et al. in Cell Tissue Bank 10:215–219, 2009) we presented the effect of various methods of preservation (deep fresh freezing, glycerolization, lyophilization), followed by irradiation with different doses of electron beam (EB), on material (intrinsic) mechanical properties of human patellar tendons cut out as for anterior cruciate ligament reconstruction, obtained in failure tensile test. As structural mechanical properties are equally important to predict the behaviour of the graft as a whole functional unit, the purpose of the present paper was to show the results for failure load and elongation, obtained in the same experiment. Paired Bone-Tendon-Bone grafts (BTB) were prepared from cadaveric human patella tendons with both patellar and tibial attachments. They were preserved by deep freezing, glycerolization or lyophilization and subsequently EB-irradiated with the doses of 25, 35, 50 or 100 kGy (fresh-frozen grafts) or a single dose of 35 kGy (glycerolized and lyophilized grafts). Each experimental (irradiated) group was provided with control (non-irradiated), donor-matched group. The specimens from all groups were subjected to mechanical failure tensile test with the use of Instron system in order to measure their structural properties (failure load and elongation). All lyophilized grafts were rehydrated before mechanical testing. In our study we did not observe significant deterioration of structural mechanical properties of BTB grafts processed by fresh-freezing and then terminal sterilized with growing doses of EB up to 100 kGy. In contrast, BTB grafts processed by glycerolization or lyophilization and irradiated with 35 kGy showed significant decrease of failure load. Obtained results suggest that deep-frozen irradiated grafts retain their initial mechanical properties to an extent which does not exclude their clinical application. However, biomechanical investigations constitute only the first step to evaluate the potential clinical usefulness of such allografts and further extensive in vivo studies are needed. Springer Netherlands 2015-12-17 2016 /pmc/articles/PMC4882344/ /pubmed/26679928 http://dx.doi.org/10.1007/s10561-015-9538-1 Text en © The Author(s) 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Paper
Gut, Grzegorz
Marowska, Joanna
Jastrzebska, Anna
Olender, Ewa
Kamiński, Artur
Structural mechanical properties of radiation-sterilized human Bone-Tendon-Bone grafts preserved by different methods
title Structural mechanical properties of radiation-sterilized human Bone-Tendon-Bone grafts preserved by different methods
title_full Structural mechanical properties of radiation-sterilized human Bone-Tendon-Bone grafts preserved by different methods
title_fullStr Structural mechanical properties of radiation-sterilized human Bone-Tendon-Bone grafts preserved by different methods
title_full_unstemmed Structural mechanical properties of radiation-sterilized human Bone-Tendon-Bone grafts preserved by different methods
title_short Structural mechanical properties of radiation-sterilized human Bone-Tendon-Bone grafts preserved by different methods
title_sort structural mechanical properties of radiation-sterilized human bone-tendon-bone grafts preserved by different methods
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4882344/
https://www.ncbi.nlm.nih.gov/pubmed/26679928
http://dx.doi.org/10.1007/s10561-015-9538-1
work_keys_str_mv AT gutgrzegorz structuralmechanicalpropertiesofradiationsterilizedhumanbonetendonbonegraftspreservedbydifferentmethods
AT marowskajoanna structuralmechanicalpropertiesofradiationsterilizedhumanbonetendonbonegraftspreservedbydifferentmethods
AT jastrzebskaanna structuralmechanicalpropertiesofradiationsterilizedhumanbonetendonbonegraftspreservedbydifferentmethods
AT olenderewa structuralmechanicalpropertiesofradiationsterilizedhumanbonetendonbonegraftspreservedbydifferentmethods
AT kaminskiartur structuralmechanicalpropertiesofradiationsterilizedhumanbonetendonbonegraftspreservedbydifferentmethods