Cargando…
Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects
Diagnostic test accuracy of D-dimer for acute aortic dissection (AAD) has not been evaluated by meta-analysis with the bivariate model methodology. Four databases were electrically searched. We included both case-control and cohort studies that could provide sufficient data concerning both sensitivi...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4882530/ https://www.ncbi.nlm.nih.gov/pubmed/27230962 http://dx.doi.org/10.1038/srep26893 |
_version_ | 1782434127762423808 |
---|---|
author | Watanabe, Hiroki Horita, Nobuyuki Shibata, Yuji Minegishi, Shintaro Ota, Erika Kaneko, Takeshi |
author_facet | Watanabe, Hiroki Horita, Nobuyuki Shibata, Yuji Minegishi, Shintaro Ota, Erika Kaneko, Takeshi |
author_sort | Watanabe, Hiroki |
collection | PubMed |
description | Diagnostic test accuracy of D-dimer for acute aortic dissection (AAD) has not been evaluated by meta-analysis with the bivariate model methodology. Four databases were electrically searched. We included both case-control and cohort studies that could provide sufficient data concerning both sensitivity and specificity of D-dimer for AAD. Non-English language articles and conference abstract were allowed. Intramural hematoma and penetrating aortic ulcer were regarded as AAD. Based on 22 eligible articles consisting of 1140 AAD subjects and 3860 non-AAD subjects, the diagnostic odds ratio was 28.5 (95% CI 17.6–46.3, I(2) = 17.4%) and the area under curve was 0.946 (95% CI 0.903–0.994). Based on 833 AAD subjects and 1994 non-AAD subjects constituting 12 studies that used the cutoff value of 500 ng/ml, the sensitivity was 0.952 (95% CI 0.901–0.978), the specificity was 0.604 (95% CI 0.485–0.712), positive likelihood ratio was 2.4 (95% CI 1.8–3.3), and negative likelihood ratio was 0.079 (95% CI 0.036–0.172). Sensitivity analysis using data of three high-quality studies almost replicated these results. In conclusion, D-dimer has very good overall accuracy. D-dimer <500 ng/ml largely decreases the possibility of AAD. D-dimer >500 ng/ml moderately increases the possibility of AAD. |
format | Online Article Text |
id | pubmed-4882530 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-48825302016-06-08 Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects Watanabe, Hiroki Horita, Nobuyuki Shibata, Yuji Minegishi, Shintaro Ota, Erika Kaneko, Takeshi Sci Rep Article Diagnostic test accuracy of D-dimer for acute aortic dissection (AAD) has not been evaluated by meta-analysis with the bivariate model methodology. Four databases were electrically searched. We included both case-control and cohort studies that could provide sufficient data concerning both sensitivity and specificity of D-dimer for AAD. Non-English language articles and conference abstract were allowed. Intramural hematoma and penetrating aortic ulcer were regarded as AAD. Based on 22 eligible articles consisting of 1140 AAD subjects and 3860 non-AAD subjects, the diagnostic odds ratio was 28.5 (95% CI 17.6–46.3, I(2) = 17.4%) and the area under curve was 0.946 (95% CI 0.903–0.994). Based on 833 AAD subjects and 1994 non-AAD subjects constituting 12 studies that used the cutoff value of 500 ng/ml, the sensitivity was 0.952 (95% CI 0.901–0.978), the specificity was 0.604 (95% CI 0.485–0.712), positive likelihood ratio was 2.4 (95% CI 1.8–3.3), and negative likelihood ratio was 0.079 (95% CI 0.036–0.172). Sensitivity analysis using data of three high-quality studies almost replicated these results. In conclusion, D-dimer has very good overall accuracy. D-dimer <500 ng/ml largely decreases the possibility of AAD. D-dimer >500 ng/ml moderately increases the possibility of AAD. Nature Publishing Group 2016-05-27 /pmc/articles/PMC4882530/ /pubmed/27230962 http://dx.doi.org/10.1038/srep26893 Text en Copyright © 2016, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Watanabe, Hiroki Horita, Nobuyuki Shibata, Yuji Minegishi, Shintaro Ota, Erika Kaneko, Takeshi Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects |
title | Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects |
title_full | Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects |
title_fullStr | Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects |
title_full_unstemmed | Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects |
title_short | Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects |
title_sort | diagnostic test accuracy of d-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4882530/ https://www.ncbi.nlm.nih.gov/pubmed/27230962 http://dx.doi.org/10.1038/srep26893 |
work_keys_str_mv | AT watanabehiroki diagnostictestaccuracyofddimerforacuteaorticsyndromesystematicreviewandmetaanalysisof22studieswith5000subjects AT horitanobuyuki diagnostictestaccuracyofddimerforacuteaorticsyndromesystematicreviewandmetaanalysisof22studieswith5000subjects AT shibatayuji diagnostictestaccuracyofddimerforacuteaorticsyndromesystematicreviewandmetaanalysisof22studieswith5000subjects AT minegishishintaro diagnostictestaccuracyofddimerforacuteaorticsyndromesystematicreviewandmetaanalysisof22studieswith5000subjects AT otaerika diagnostictestaccuracyofddimerforacuteaorticsyndromesystematicreviewandmetaanalysisof22studieswith5000subjects AT kanekotakeshi diagnostictestaccuracyofddimerforacuteaorticsyndromesystematicreviewandmetaanalysisof22studieswith5000subjects |