Cargando…

Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects

Diagnostic test accuracy of D-dimer for acute aortic dissection (AAD) has not been evaluated by meta-analysis with the bivariate model methodology. Four databases were electrically searched. We included both case-control and cohort studies that could provide sufficient data concerning both sensitivi...

Descripción completa

Detalles Bibliográficos
Autores principales: Watanabe, Hiroki, Horita, Nobuyuki, Shibata, Yuji, Minegishi, Shintaro, Ota, Erika, Kaneko, Takeshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4882530/
https://www.ncbi.nlm.nih.gov/pubmed/27230962
http://dx.doi.org/10.1038/srep26893
_version_ 1782434127762423808
author Watanabe, Hiroki
Horita, Nobuyuki
Shibata, Yuji
Minegishi, Shintaro
Ota, Erika
Kaneko, Takeshi
author_facet Watanabe, Hiroki
Horita, Nobuyuki
Shibata, Yuji
Minegishi, Shintaro
Ota, Erika
Kaneko, Takeshi
author_sort Watanabe, Hiroki
collection PubMed
description Diagnostic test accuracy of D-dimer for acute aortic dissection (AAD) has not been evaluated by meta-analysis with the bivariate model methodology. Four databases were electrically searched. We included both case-control and cohort studies that could provide sufficient data concerning both sensitivity and specificity of D-dimer for AAD. Non-English language articles and conference abstract were allowed. Intramural hematoma and penetrating aortic ulcer were regarded as AAD. Based on 22 eligible articles consisting of 1140 AAD subjects and 3860 non-AAD subjects, the diagnostic odds ratio was 28.5 (95% CI 17.6–46.3, I(2) = 17.4%) and the area under curve was 0.946 (95% CI 0.903–0.994). Based on 833 AAD subjects and 1994 non-AAD subjects constituting 12 studies that used the cutoff value of 500 ng/ml, the sensitivity was 0.952 (95% CI 0.901–0.978), the specificity was 0.604 (95% CI 0.485–0.712), positive likelihood ratio was 2.4 (95% CI 1.8–3.3), and negative likelihood ratio was 0.079 (95% CI 0.036–0.172). Sensitivity analysis using data of three high-quality studies almost replicated these results. In conclusion, D-dimer has very good overall accuracy. D-dimer <500 ng/ml largely decreases the possibility of AAD. D-dimer >500 ng/ml moderately increases the possibility of AAD.
format Online
Article
Text
id pubmed-4882530
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-48825302016-06-08 Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects Watanabe, Hiroki Horita, Nobuyuki Shibata, Yuji Minegishi, Shintaro Ota, Erika Kaneko, Takeshi Sci Rep Article Diagnostic test accuracy of D-dimer for acute aortic dissection (AAD) has not been evaluated by meta-analysis with the bivariate model methodology. Four databases were electrically searched. We included both case-control and cohort studies that could provide sufficient data concerning both sensitivity and specificity of D-dimer for AAD. Non-English language articles and conference abstract were allowed. Intramural hematoma and penetrating aortic ulcer were regarded as AAD. Based on 22 eligible articles consisting of 1140 AAD subjects and 3860 non-AAD subjects, the diagnostic odds ratio was 28.5 (95% CI 17.6–46.3, I(2) = 17.4%) and the area under curve was 0.946 (95% CI 0.903–0.994). Based on 833 AAD subjects and 1994 non-AAD subjects constituting 12 studies that used the cutoff value of 500 ng/ml, the sensitivity was 0.952 (95% CI 0.901–0.978), the specificity was 0.604 (95% CI 0.485–0.712), positive likelihood ratio was 2.4 (95% CI 1.8–3.3), and negative likelihood ratio was 0.079 (95% CI 0.036–0.172). Sensitivity analysis using data of three high-quality studies almost replicated these results. In conclusion, D-dimer has very good overall accuracy. D-dimer <500 ng/ml largely decreases the possibility of AAD. D-dimer >500 ng/ml moderately increases the possibility of AAD. Nature Publishing Group 2016-05-27 /pmc/articles/PMC4882530/ /pubmed/27230962 http://dx.doi.org/10.1038/srep26893 Text en Copyright © 2016, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Watanabe, Hiroki
Horita, Nobuyuki
Shibata, Yuji
Minegishi, Shintaro
Ota, Erika
Kaneko, Takeshi
Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects
title Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects
title_full Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects
title_fullStr Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects
title_full_unstemmed Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects
title_short Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects
title_sort diagnostic test accuracy of d-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4882530/
https://www.ncbi.nlm.nih.gov/pubmed/27230962
http://dx.doi.org/10.1038/srep26893
work_keys_str_mv AT watanabehiroki diagnostictestaccuracyofddimerforacuteaorticsyndromesystematicreviewandmetaanalysisof22studieswith5000subjects
AT horitanobuyuki diagnostictestaccuracyofddimerforacuteaorticsyndromesystematicreviewandmetaanalysisof22studieswith5000subjects
AT shibatayuji diagnostictestaccuracyofddimerforacuteaorticsyndromesystematicreviewandmetaanalysisof22studieswith5000subjects
AT minegishishintaro diagnostictestaccuracyofddimerforacuteaorticsyndromesystematicreviewandmetaanalysisof22studieswith5000subjects
AT otaerika diagnostictestaccuracyofddimerforacuteaorticsyndromesystematicreviewandmetaanalysisof22studieswith5000subjects
AT kanekotakeshi diagnostictestaccuracyofddimerforacuteaorticsyndromesystematicreviewandmetaanalysisof22studieswith5000subjects