Cargando…
Analysis and Calibration of Sources of Electronic Error in PSD Sensor Response
In order to obtain very precise measurements of the position of agents located at a considerable distance using a sensor system based on position sensitive detectors (PSD), it is necessary to analyze and mitigate the factors that generate substantial errors in the system’s response. These sources of...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4883310/ https://www.ncbi.nlm.nih.gov/pubmed/27136562 http://dx.doi.org/10.3390/s16050619 |
_version_ | 1782434247786627072 |
---|---|
author | Rodríguez-Navarro, David Lázaro-Galilea, José Luis Bravo-Muñoz, Ignacio Gardel-Vicente, Alfredo Tsirigotis, Georgios |
author_facet | Rodríguez-Navarro, David Lázaro-Galilea, José Luis Bravo-Muñoz, Ignacio Gardel-Vicente, Alfredo Tsirigotis, Georgios |
author_sort | Rodríguez-Navarro, David |
collection | PubMed |
description | In order to obtain very precise measurements of the position of agents located at a considerable distance using a sensor system based on position sensitive detectors (PSD), it is necessary to analyze and mitigate the factors that generate substantial errors in the system’s response. These sources of error can be divided into electronic and geometric factors. The former stem from the nature and construction of the PSD as well as the performance, tolerances and electronic response of the system, while the latter are related to the sensor’s optical system. Here, we focus solely on the electrical effects, since the study, analysis and correction of these are a prerequisite for subsequently addressing geometric errors. A simple calibration method is proposed, which considers PSD response, component tolerances, temperature variations, signal frequency used, signal to noise ratio (SNR), suboptimal operational amplifier parameters, and analog to digital converter (ADC) quantitation SNR(Q), etc. Following an analysis of these effects and calibration of the sensor, it was possible to correct the errors, thus rendering the effects negligible, as reported in the results section. |
format | Online Article Text |
id | pubmed-4883310 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-48833102016-05-27 Analysis and Calibration of Sources of Electronic Error in PSD Sensor Response Rodríguez-Navarro, David Lázaro-Galilea, José Luis Bravo-Muñoz, Ignacio Gardel-Vicente, Alfredo Tsirigotis, Georgios Sensors (Basel) Article In order to obtain very precise measurements of the position of agents located at a considerable distance using a sensor system based on position sensitive detectors (PSD), it is necessary to analyze and mitigate the factors that generate substantial errors in the system’s response. These sources of error can be divided into electronic and geometric factors. The former stem from the nature and construction of the PSD as well as the performance, tolerances and electronic response of the system, while the latter are related to the sensor’s optical system. Here, we focus solely on the electrical effects, since the study, analysis and correction of these are a prerequisite for subsequently addressing geometric errors. A simple calibration method is proposed, which considers PSD response, component tolerances, temperature variations, signal frequency used, signal to noise ratio (SNR), suboptimal operational amplifier parameters, and analog to digital converter (ADC) quantitation SNR(Q), etc. Following an analysis of these effects and calibration of the sensor, it was possible to correct the errors, thus rendering the effects negligible, as reported in the results section. MDPI 2016-04-29 /pmc/articles/PMC4883310/ /pubmed/27136562 http://dx.doi.org/10.3390/s16050619 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Rodríguez-Navarro, David Lázaro-Galilea, José Luis Bravo-Muñoz, Ignacio Gardel-Vicente, Alfredo Tsirigotis, Georgios Analysis and Calibration of Sources of Electronic Error in PSD Sensor Response |
title | Analysis and Calibration of Sources of Electronic Error in PSD Sensor Response |
title_full | Analysis and Calibration of Sources of Electronic Error in PSD Sensor Response |
title_fullStr | Analysis and Calibration of Sources of Electronic Error in PSD Sensor Response |
title_full_unstemmed | Analysis and Calibration of Sources of Electronic Error in PSD Sensor Response |
title_short | Analysis and Calibration of Sources of Electronic Error in PSD Sensor Response |
title_sort | analysis and calibration of sources of electronic error in psd sensor response |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4883310/ https://www.ncbi.nlm.nih.gov/pubmed/27136562 http://dx.doi.org/10.3390/s16050619 |
work_keys_str_mv | AT rodrigueznavarrodavid analysisandcalibrationofsourcesofelectronicerrorinpsdsensorresponse AT lazarogalileajoseluis analysisandcalibrationofsourcesofelectronicerrorinpsdsensorresponse AT bravomunozignacio analysisandcalibrationofsourcesofelectronicerrorinpsdsensorresponse AT gardelvicentealfredo analysisandcalibrationofsourcesofelectronicerrorinpsdsensorresponse AT tsirigotisgeorgios analysisandcalibrationofsourcesofelectronicerrorinpsdsensorresponse |