Cargando…

Absolute Position Sensing Based on a Robust Differential Capacitive Sensor with a Grounded Shield Window

A simple differential capacitive sensor is provided in this paper to measure the absolute positions of length measuring systems. By utilizing a shield window inside the differential capacitor, the measurement range and linearity range of the sensor can reach several millimeters. What is more interes...

Descripción completa

Detalles Bibliográficos
Autores principales: Bai, Yang, Lu, Yunfeng, Hu, Pengcheng, Wang, Gang, Xu, Jinxin, Zeng, Tao, Li, Zhengkun, Zhang, Zhonghua, Tan, Jiubin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4883371/
https://www.ncbi.nlm.nih.gov/pubmed/27187393
http://dx.doi.org/10.3390/s16050680
_version_ 1782434261470543872
author Bai, Yang
Lu, Yunfeng
Hu, Pengcheng
Wang, Gang
Xu, Jinxin
Zeng, Tao
Li, Zhengkun
Zhang, Zhonghua
Tan, Jiubin
author_facet Bai, Yang
Lu, Yunfeng
Hu, Pengcheng
Wang, Gang
Xu, Jinxin
Zeng, Tao
Li, Zhengkun
Zhang, Zhonghua
Tan, Jiubin
author_sort Bai, Yang
collection PubMed
description A simple differential capacitive sensor is provided in this paper to measure the absolute positions of length measuring systems. By utilizing a shield window inside the differential capacitor, the measurement range and linearity range of the sensor can reach several millimeters. What is more interesting is that this differential capacitive sensor is only sensitive to one translational degree of freedom (DOF) movement, and immune to the vibration along the other two translational DOFs. In the experiment, we used a novel circuit based on an AC capacitance bridge to directly measure the differential capacitance value. The experimental result shows that this differential capacitive sensor has a sensitivity of 2 × 10(−4) pF/μm with 0.08 μm resolution. The measurement range of this differential capacitive sensor is 6 mm, and the linearity error are less than 0.01% over the whole absolute position measurement range.
format Online
Article
Text
id pubmed-4883371
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-48833712016-05-27 Absolute Position Sensing Based on a Robust Differential Capacitive Sensor with a Grounded Shield Window Bai, Yang Lu, Yunfeng Hu, Pengcheng Wang, Gang Xu, Jinxin Zeng, Tao Li, Zhengkun Zhang, Zhonghua Tan, Jiubin Sensors (Basel) Article A simple differential capacitive sensor is provided in this paper to measure the absolute positions of length measuring systems. By utilizing a shield window inside the differential capacitor, the measurement range and linearity range of the sensor can reach several millimeters. What is more interesting is that this differential capacitive sensor is only sensitive to one translational degree of freedom (DOF) movement, and immune to the vibration along the other two translational DOFs. In the experiment, we used a novel circuit based on an AC capacitance bridge to directly measure the differential capacitance value. The experimental result shows that this differential capacitive sensor has a sensitivity of 2 × 10(−4) pF/μm with 0.08 μm resolution. The measurement range of this differential capacitive sensor is 6 mm, and the linearity error are less than 0.01% over the whole absolute position measurement range. MDPI 2016-05-11 /pmc/articles/PMC4883371/ /pubmed/27187393 http://dx.doi.org/10.3390/s16050680 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bai, Yang
Lu, Yunfeng
Hu, Pengcheng
Wang, Gang
Xu, Jinxin
Zeng, Tao
Li, Zhengkun
Zhang, Zhonghua
Tan, Jiubin
Absolute Position Sensing Based on a Robust Differential Capacitive Sensor with a Grounded Shield Window
title Absolute Position Sensing Based on a Robust Differential Capacitive Sensor with a Grounded Shield Window
title_full Absolute Position Sensing Based on a Robust Differential Capacitive Sensor with a Grounded Shield Window
title_fullStr Absolute Position Sensing Based on a Robust Differential Capacitive Sensor with a Grounded Shield Window
title_full_unstemmed Absolute Position Sensing Based on a Robust Differential Capacitive Sensor with a Grounded Shield Window
title_short Absolute Position Sensing Based on a Robust Differential Capacitive Sensor with a Grounded Shield Window
title_sort absolute position sensing based on a robust differential capacitive sensor with a grounded shield window
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4883371/
https://www.ncbi.nlm.nih.gov/pubmed/27187393
http://dx.doi.org/10.3390/s16050680
work_keys_str_mv AT baiyang absolutepositionsensingbasedonarobustdifferentialcapacitivesensorwithagroundedshieldwindow
AT luyunfeng absolutepositionsensingbasedonarobustdifferentialcapacitivesensorwithagroundedshieldwindow
AT hupengcheng absolutepositionsensingbasedonarobustdifferentialcapacitivesensorwithagroundedshieldwindow
AT wanggang absolutepositionsensingbasedonarobustdifferentialcapacitivesensorwithagroundedshieldwindow
AT xujinxin absolutepositionsensingbasedonarobustdifferentialcapacitivesensorwithagroundedshieldwindow
AT zengtao absolutepositionsensingbasedonarobustdifferentialcapacitivesensorwithagroundedshieldwindow
AT lizhengkun absolutepositionsensingbasedonarobustdifferentialcapacitivesensorwithagroundedshieldwindow
AT zhangzhonghua absolutepositionsensingbasedonarobustdifferentialcapacitivesensorwithagroundedshieldwindow
AT tanjiubin absolutepositionsensingbasedonarobustdifferentialcapacitivesensorwithagroundedshieldwindow