Cargando…

An Uncemented Spreading Stem for the Fixation in the Metaphyseal Femur: A Preliminary Report

Surgical treatment to restore full range of motion and full weight bearing after extensive femoral bone resection in patients with primary or metastatic femoral tumours is individually challenging. Especially when the remaining distal or proximal bone is very short, a rigid fixation of an implant is...

Descripción completa

Detalles Bibliográficos
Autores principales: Burger, Daniel, Pumberger, Matthias, Fuchs, Bruno
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4884583/
https://www.ncbi.nlm.nih.gov/pubmed/27293377
http://dx.doi.org/10.1155/2016/7132838
_version_ 1782434384506257408
author Burger, Daniel
Pumberger, Matthias
Fuchs, Bruno
author_facet Burger, Daniel
Pumberger, Matthias
Fuchs, Bruno
author_sort Burger, Daniel
collection PubMed
description Surgical treatment to restore full range of motion and full weight bearing after extensive femoral bone resection in patients with primary or metastatic femoral tumours is individually challenging. Especially when the remaining distal or proximal bone is very short, a rigid fixation of an implant is difficult to achieve due to the reverse funnel shape of the metaphysis. Herein, we present a novel implant design using a spreading mechanism in the distal part of the prosthesis for rigid, uncemented fixation in the remaining femoral bone after extensive tumour resection of the femur. We present the outcome of 5 female patients who underwent implantation of this spreading stem after extensive proximal or distal femoral bone resection. There was no radiological or clinical loosening or implant-related revision surgery in our follow-up (mean 21.46 months, range 3.5–46 months). This uncemented spreading stem may therefore represent an alternative option for fixation of a prosthetic device in the remaining metaphyseal femur.
format Online
Article
Text
id pubmed-4884583
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-48845832016-06-12 An Uncemented Spreading Stem for the Fixation in the Metaphyseal Femur: A Preliminary Report Burger, Daniel Pumberger, Matthias Fuchs, Bruno Sarcoma Clinical Study Surgical treatment to restore full range of motion and full weight bearing after extensive femoral bone resection in patients with primary or metastatic femoral tumours is individually challenging. Especially when the remaining distal or proximal bone is very short, a rigid fixation of an implant is difficult to achieve due to the reverse funnel shape of the metaphysis. Herein, we present a novel implant design using a spreading mechanism in the distal part of the prosthesis for rigid, uncemented fixation in the remaining femoral bone after extensive tumour resection of the femur. We present the outcome of 5 female patients who underwent implantation of this spreading stem after extensive proximal or distal femoral bone resection. There was no radiological or clinical loosening or implant-related revision surgery in our follow-up (mean 21.46 months, range 3.5–46 months). This uncemented spreading stem may therefore represent an alternative option for fixation of a prosthetic device in the remaining metaphyseal femur. Hindawi Publishing Corporation 2016 2016-05-15 /pmc/articles/PMC4884583/ /pubmed/27293377 http://dx.doi.org/10.1155/2016/7132838 Text en Copyright © 2016 Daniel Burger et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Burger, Daniel
Pumberger, Matthias
Fuchs, Bruno
An Uncemented Spreading Stem for the Fixation in the Metaphyseal Femur: A Preliminary Report
title An Uncemented Spreading Stem for the Fixation in the Metaphyseal Femur: A Preliminary Report
title_full An Uncemented Spreading Stem for the Fixation in the Metaphyseal Femur: A Preliminary Report
title_fullStr An Uncemented Spreading Stem for the Fixation in the Metaphyseal Femur: A Preliminary Report
title_full_unstemmed An Uncemented Spreading Stem for the Fixation in the Metaphyseal Femur: A Preliminary Report
title_short An Uncemented Spreading Stem for the Fixation in the Metaphyseal Femur: A Preliminary Report
title_sort uncemented spreading stem for the fixation in the metaphyseal femur: a preliminary report
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4884583/
https://www.ncbi.nlm.nih.gov/pubmed/27293377
http://dx.doi.org/10.1155/2016/7132838
work_keys_str_mv AT burgerdaniel anuncementedspreadingstemforthefixationinthemetaphysealfemurapreliminaryreport
AT pumbergermatthias anuncementedspreadingstemforthefixationinthemetaphysealfemurapreliminaryreport
AT fuchsbruno anuncementedspreadingstemforthefixationinthemetaphysealfemurapreliminaryreport
AT burgerdaniel uncementedspreadingstemforthefixationinthemetaphysealfemurapreliminaryreport
AT pumbergermatthias uncementedspreadingstemforthefixationinthemetaphysealfemurapreliminaryreport
AT fuchsbruno uncementedspreadingstemforthefixationinthemetaphysealfemurapreliminaryreport