Cargando…

Increasing compliance with low tidal volume ventilation in the ICU with two nudge-based interventions: evaluation through intervention time-series analyses

OBJECTIVES: Low tidal volume (TVe) ventilation improves outcomes for ventilated patients, and the majority of clinicians state they implement it. Unfortunately, most patients never receive low TVes. ‘Nudges’ influence decision-making with subtle cognitive mechanisms and are effective in many context...

Descripción completa

Detalles Bibliográficos
Autores principales: Bourdeaux, Christopher P, Thomas, Matthew JC, Gould, Timothy H, Malhotra, Gaurav, Jarvstad, Andreas, Jones, Timothy, Gilchrist, Iain D
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4885280/
https://www.ncbi.nlm.nih.gov/pubmed/27230998
http://dx.doi.org/10.1136/bmjopen-2015-010129
_version_ 1782434496783581184
author Bourdeaux, Christopher P
Thomas, Matthew JC
Gould, Timothy H
Malhotra, Gaurav
Jarvstad, Andreas
Jones, Timothy
Gilchrist, Iain D
author_facet Bourdeaux, Christopher P
Thomas, Matthew JC
Gould, Timothy H
Malhotra, Gaurav
Jarvstad, Andreas
Jones, Timothy
Gilchrist, Iain D
author_sort Bourdeaux, Christopher P
collection PubMed
description OBJECTIVES: Low tidal volume (TVe) ventilation improves outcomes for ventilated patients, and the majority of clinicians state they implement it. Unfortunately, most patients never receive low TVes. ‘Nudges’ influence decision-making with subtle cognitive mechanisms and are effective in many contexts. There have been few studies examining their impact on clinical decision-making. We investigated the impact of 2 interventions designed using principles from behavioural science on the deployment of low TVe ventilation in the intensive care unit (ICU). SETTING: University Hospitals Bristol, a tertiary, mixed medical and surgical ICU with 20 beds, admitting over 1300 patients per year. PARTICIPANTS: Data were collected from 2144 consecutive patients receiving controlled mechanical ventilation for more than 1 hour between October 2010 and September 2014. Patients on controlled mechanical ventilation for more than 20 hours were included in the final analysis. INTERVENTIONS: (1) Default ventilator settings were adjusted to comply with low TVe targets from the initiation of ventilation unless actively changed by a clinician. (2) A large dashboard was deployed displaying TVes in the format mL/kg ideal body weight (IBW) with alerts when TVes were excessive. PRIMARY OUTCOME MEASURE: TVe in mL/kg IBW. FINDINGS: TVe was significantly lower in the defaults group. In the dashboard intervention, TVe fell more quickly and by a greater amount after a TVe of 8 mL/kg IBW was breached when compared with controls. This effect improved in each subsequent year for 3 years. CONCLUSIONS: This study has demonstrated that adjustment of default ventilator settings and a dashboard with alerts for excessive TVe can significantly influence clinical decision-making. This offers a promising strategy to improve compliance with low TVe ventilation, and suggests that using insights from behavioural science has potential to improve the translation of evidence into practice.
format Online
Article
Text
id pubmed-4885280
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-48852802016-06-01 Increasing compliance with low tidal volume ventilation in the ICU with two nudge-based interventions: evaluation through intervention time-series analyses Bourdeaux, Christopher P Thomas, Matthew JC Gould, Timothy H Malhotra, Gaurav Jarvstad, Andreas Jones, Timothy Gilchrist, Iain D BMJ Open Intensive Care OBJECTIVES: Low tidal volume (TVe) ventilation improves outcomes for ventilated patients, and the majority of clinicians state they implement it. Unfortunately, most patients never receive low TVes. ‘Nudges’ influence decision-making with subtle cognitive mechanisms and are effective in many contexts. There have been few studies examining their impact on clinical decision-making. We investigated the impact of 2 interventions designed using principles from behavioural science on the deployment of low TVe ventilation in the intensive care unit (ICU). SETTING: University Hospitals Bristol, a tertiary, mixed medical and surgical ICU with 20 beds, admitting over 1300 patients per year. PARTICIPANTS: Data were collected from 2144 consecutive patients receiving controlled mechanical ventilation for more than 1 hour between October 2010 and September 2014. Patients on controlled mechanical ventilation for more than 20 hours were included in the final analysis. INTERVENTIONS: (1) Default ventilator settings were adjusted to comply with low TVe targets from the initiation of ventilation unless actively changed by a clinician. (2) A large dashboard was deployed displaying TVes in the format mL/kg ideal body weight (IBW) with alerts when TVes were excessive. PRIMARY OUTCOME MEASURE: TVe in mL/kg IBW. FINDINGS: TVe was significantly lower in the defaults group. In the dashboard intervention, TVe fell more quickly and by a greater amount after a TVe of 8 mL/kg IBW was breached when compared with controls. This effect improved in each subsequent year for 3 years. CONCLUSIONS: This study has demonstrated that adjustment of default ventilator settings and a dashboard with alerts for excessive TVe can significantly influence clinical decision-making. This offers a promising strategy to improve compliance with low TVe ventilation, and suggests that using insights from behavioural science has potential to improve the translation of evidence into practice. BMJ Publishing Group 2016-05-26 /pmc/articles/PMC4885280/ /pubmed/27230998 http://dx.doi.org/10.1136/bmjopen-2015-010129 Text en Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/ This is an Open Access article distributed in accordance with the terms of the Creative Commons Attribution (CC BY 4.0) license, which permits others to distribute, remix, adapt and build upon this work, for commercial use, provided the original work is properly cited. See: http://creativecommons.org/licenses/by/4.0/
spellingShingle Intensive Care
Bourdeaux, Christopher P
Thomas, Matthew JC
Gould, Timothy H
Malhotra, Gaurav
Jarvstad, Andreas
Jones, Timothy
Gilchrist, Iain D
Increasing compliance with low tidal volume ventilation in the ICU with two nudge-based interventions: evaluation through intervention time-series analyses
title Increasing compliance with low tidal volume ventilation in the ICU with two nudge-based interventions: evaluation through intervention time-series analyses
title_full Increasing compliance with low tidal volume ventilation in the ICU with two nudge-based interventions: evaluation through intervention time-series analyses
title_fullStr Increasing compliance with low tidal volume ventilation in the ICU with two nudge-based interventions: evaluation through intervention time-series analyses
title_full_unstemmed Increasing compliance with low tidal volume ventilation in the ICU with two nudge-based interventions: evaluation through intervention time-series analyses
title_short Increasing compliance with low tidal volume ventilation in the ICU with two nudge-based interventions: evaluation through intervention time-series analyses
title_sort increasing compliance with low tidal volume ventilation in the icu with two nudge-based interventions: evaluation through intervention time-series analyses
topic Intensive Care
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4885280/
https://www.ncbi.nlm.nih.gov/pubmed/27230998
http://dx.doi.org/10.1136/bmjopen-2015-010129
work_keys_str_mv AT bourdeauxchristopherp increasingcompliancewithlowtidalvolumeventilationintheicuwithtwonudgebasedinterventionsevaluationthroughinterventiontimeseriesanalyses
AT thomasmatthewjc increasingcompliancewithlowtidalvolumeventilationintheicuwithtwonudgebasedinterventionsevaluationthroughinterventiontimeseriesanalyses
AT gouldtimothyh increasingcompliancewithlowtidalvolumeventilationintheicuwithtwonudgebasedinterventionsevaluationthroughinterventiontimeseriesanalyses
AT malhotragaurav increasingcompliancewithlowtidalvolumeventilationintheicuwithtwonudgebasedinterventionsevaluationthroughinterventiontimeseriesanalyses
AT jarvstadandreas increasingcompliancewithlowtidalvolumeventilationintheicuwithtwonudgebasedinterventionsevaluationthroughinterventiontimeseriesanalyses
AT jonestimothy increasingcompliancewithlowtidalvolumeventilationintheicuwithtwonudgebasedinterventionsevaluationthroughinterventiontimeseriesanalyses
AT gilchristiaind increasingcompliancewithlowtidalvolumeventilationintheicuwithtwonudgebasedinterventionsevaluationthroughinterventiontimeseriesanalyses