Cargando…

Minimally invasive surgery under fluoro-navigation for anterior pelvic ring fractures

BACKGROUND: The incidence of pelvic fractures in trauma patients is reported to be 3–8.2%, with roughly half of these fractures being caused by high energy injuries with a potential for catastrophic hemorrhage and death. Indications for internal fixation of anterior pelvic ring are controversial. Be...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Kai-Hua, Luo, Cong-Feng, Chen, Nong, Hu, Cheng-Fang, Pan, Fu-Gen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4885292/
https://www.ncbi.nlm.nih.gov/pubmed/27293284
http://dx.doi.org/10.4103/0019-5413.181791
_version_ 1782434499308552192
author Zhou, Kai-Hua
Luo, Cong-Feng
Chen, Nong
Hu, Cheng-Fang
Pan, Fu-Gen
author_facet Zhou, Kai-Hua
Luo, Cong-Feng
Chen, Nong
Hu, Cheng-Fang
Pan, Fu-Gen
author_sort Zhou, Kai-Hua
collection PubMed
description BACKGROUND: The incidence of pelvic fractures in trauma patients is reported to be 3–8.2%, with roughly half of these fractures being caused by high energy injuries with a potential for catastrophic hemorrhage and death. Indications for internal fixation of anterior pelvic ring are controversial. Because of fears of disturbing the pelvic hematoma and causing additional hemorrhage, open reduction and internal fixation of pelvic ring disruption is routinely delayed. In contrast to conventional surgery, percutaneous screw fixation is gaining popularity in the treatment of pelvic and acetabular fractures mainly because of minimal soft tissue damage, less operative blood loss, early surgical intervention and comfortable mobilization of the patient. Fluoro-navigation is a new surgical technique in orthopedic trauma surgery. This study is to investigate clinical results of fluoro-navigation surgery in anterior pelvic ring fractures. MATERIALS AND METHODS: From January 2006 to October 2011, 23 patients with anterior pelvic ring fractures were treated with percutaneous cannulated screw under fluoro-navigation. There were 14 men and 9 women, with a mean age of 40.1 years (range 25–55). According to the AO and Orthopedic Trauma Association classification, there were seven A 2.1, two A 2.2, one A 2.3, six B 1.2, one B 2.1: 1, one B 2.2, one C 1.2, two C 1.3 and two C 2.3 types of fractures. Amongst these patients, 13 had posterior pelvic ring injuries, 8 had other injuries including urethral, lumbar vertebrae fractures and femoral fractures. All patients were operated when their general condition stabilized after emergency management. The mean time from injury to percutaneous screw fixation of the anterior pelvic ring fracture was 12 days (3–15 days). All the anterior ring fractures were fixed with cannulated screws by two senior surgeons. They were familiar with the navigation system and had gained much experience in the computer-assisted percutaneous placement of screws. RESULTS: A total of 32 screws were inserted, including 19 in the pubic ramis and 13 in the anterior acetabular columns. The average surgical time was 23.3 min/screw. The average time of X-ray exposure was 19.1 ± 2.5 s/screw. The virtual images of fluoro-navigation were compared with real-time X-rays during and after the surgery. Compared to the final position of the screw, the average deviated distance was 3.11 mm and the average trajectory difference was 2.81°. Blood loss during the operation was minimal (22.3 ml/screw). One screw (3.1%) deviated out of the fracture site during the operation. No superficial or deep infection occurred. No patient sustained recognized neurologic, vascular, or urologic injury as a result of the percutaneous screw fixation. All fractures united at the last followup. CONCLUSIONS: Fluoro-navigation technique could become a safe, accurate, and fairly quick method for the treatment of anterior pelvic ring fractures. Standardization of the operative procedure and training are mandatory for the success of this procedure.
format Online
Article
Text
id pubmed-4885292
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-48852922016-06-10 Minimally invasive surgery under fluoro-navigation for anterior pelvic ring fractures Zhou, Kai-Hua Luo, Cong-Feng Chen, Nong Hu, Cheng-Fang Pan, Fu-Gen Indian J Orthop Original Article BACKGROUND: The incidence of pelvic fractures in trauma patients is reported to be 3–8.2%, with roughly half of these fractures being caused by high energy injuries with a potential for catastrophic hemorrhage and death. Indications for internal fixation of anterior pelvic ring are controversial. Because of fears of disturbing the pelvic hematoma and causing additional hemorrhage, open reduction and internal fixation of pelvic ring disruption is routinely delayed. In contrast to conventional surgery, percutaneous screw fixation is gaining popularity in the treatment of pelvic and acetabular fractures mainly because of minimal soft tissue damage, less operative blood loss, early surgical intervention and comfortable mobilization of the patient. Fluoro-navigation is a new surgical technique in orthopedic trauma surgery. This study is to investigate clinical results of fluoro-navigation surgery in anterior pelvic ring fractures. MATERIALS AND METHODS: From January 2006 to October 2011, 23 patients with anterior pelvic ring fractures were treated with percutaneous cannulated screw under fluoro-navigation. There were 14 men and 9 women, with a mean age of 40.1 years (range 25–55). According to the AO and Orthopedic Trauma Association classification, there were seven A 2.1, two A 2.2, one A 2.3, six B 1.2, one B 2.1: 1, one B 2.2, one C 1.2, two C 1.3 and two C 2.3 types of fractures. Amongst these patients, 13 had posterior pelvic ring injuries, 8 had other injuries including urethral, lumbar vertebrae fractures and femoral fractures. All patients were operated when their general condition stabilized after emergency management. The mean time from injury to percutaneous screw fixation of the anterior pelvic ring fracture was 12 days (3–15 days). All the anterior ring fractures were fixed with cannulated screws by two senior surgeons. They were familiar with the navigation system and had gained much experience in the computer-assisted percutaneous placement of screws. RESULTS: A total of 32 screws were inserted, including 19 in the pubic ramis and 13 in the anterior acetabular columns. The average surgical time was 23.3 min/screw. The average time of X-ray exposure was 19.1 ± 2.5 s/screw. The virtual images of fluoro-navigation were compared with real-time X-rays during and after the surgery. Compared to the final position of the screw, the average deviated distance was 3.11 mm and the average trajectory difference was 2.81°. Blood loss during the operation was minimal (22.3 ml/screw). One screw (3.1%) deviated out of the fracture site during the operation. No superficial or deep infection occurred. No patient sustained recognized neurologic, vascular, or urologic injury as a result of the percutaneous screw fixation. All fractures united at the last followup. CONCLUSIONS: Fluoro-navigation technique could become a safe, accurate, and fairly quick method for the treatment of anterior pelvic ring fractures. Standardization of the operative procedure and training are mandatory for the success of this procedure. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC4885292/ /pubmed/27293284 http://dx.doi.org/10.4103/0019-5413.181791 Text en Copyright: © Indian Journal of Orthopaedics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Zhou, Kai-Hua
Luo, Cong-Feng
Chen, Nong
Hu, Cheng-Fang
Pan, Fu-Gen
Minimally invasive surgery under fluoro-navigation for anterior pelvic ring fractures
title Minimally invasive surgery under fluoro-navigation for anterior pelvic ring fractures
title_full Minimally invasive surgery under fluoro-navigation for anterior pelvic ring fractures
title_fullStr Minimally invasive surgery under fluoro-navigation for anterior pelvic ring fractures
title_full_unstemmed Minimally invasive surgery under fluoro-navigation for anterior pelvic ring fractures
title_short Minimally invasive surgery under fluoro-navigation for anterior pelvic ring fractures
title_sort minimally invasive surgery under fluoro-navigation for anterior pelvic ring fractures
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4885292/
https://www.ncbi.nlm.nih.gov/pubmed/27293284
http://dx.doi.org/10.4103/0019-5413.181791
work_keys_str_mv AT zhoukaihua minimallyinvasivesurgeryunderfluoronavigationforanteriorpelvicringfractures
AT luocongfeng minimallyinvasivesurgeryunderfluoronavigationforanteriorpelvicringfractures
AT chennong minimallyinvasivesurgeryunderfluoronavigationforanteriorpelvicringfractures
AT huchengfang minimallyinvasivesurgeryunderfluoronavigationforanteriorpelvicringfractures
AT panfugen minimallyinvasivesurgeryunderfluoronavigationforanteriorpelvicringfractures