BACKGROUND: Despite the many perceived benefits of metal-on-metal (MoM) articulation in total hip arthroplasty (THA), there have been growing concerns about metallosis and adverse reaction to metal debris (ARMD). Analysis of size 36 mm MoM articulation THAs is presented. These patients were evaluate...

Descripción completa

Detalles Bibliográficos
Autores principales: Akrawi, Hawar, Hossain, Fahad S, Niculescu, Stefan, Hashim, Zaid, Ng, Arron Biing, Shetty, Ajit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4885293/
https://www.ncbi.nlm.nih.gov/pubmed/27293285
http://dx.doi.org/10.4103/0019-5413.181786
_version_ 1782434499533996032
author Akrawi, Hawar
Hossain, Fahad S
Niculescu, Stefan
Hashim, Zaid
Ng, Arron Biing
Shetty, Ajit
author_facet Akrawi, Hawar
Hossain, Fahad S
Niculescu, Stefan
Hashim, Zaid
Ng, Arron Biing
Shetty, Ajit
author_sort Akrawi, Hawar
collection PubMed
description BACKGROUND: Despite the many perceived benefits of metal-on-metal (MoM) articulation in total hip arthroplasty (THA), there have been growing concerns about metallosis and adverse reaction to metal debris (ARMD). Analysis of size 36 mm MoM articulation THAs is presented. These patients were evaluated for patient characteristics, relationship between blood metal ions levels and the inclination as well as the version of acetabular component, cumulative survival probability at final followup and functional outcome at final followup. MATERIALS AND METHODS: 288, size 36 mm MoM THAs implanted in 269 patients at our institution from 2004 to 2010 were included in this retrospective study. These patients were assessed clinically for hip symptoms, perioperative complications and causes of revision arthroplasty were analysed. Biochemically, blood cobalt and chromium metal ions level were recorded and measurements of acetabular inclination and version were examined. Radiological evaluation utilizing Metal Artefact Reduction Sequence (MARS) MRI was undertaken and implant cumulative survivorship was evaluated. RESULTS: The mean followup was 5 years (range 2–7 years), mean age was 73 years and the mean Oxford hip score was 36.9 (range 5–48). Revision arthroplasty was executed in 20 (7.4%) patients, of which 15 patients underwent single-stage revision THA. The causes of revision arthroplasty were: ARMD changes in 6 (2.2%) patients, infection in 5 (1.9%) patients and aseptic loosening in 5 (1.9%) patients. Three (1.1%) patients had their hips revised for instability, 1 (0.3%) for raised blood metal ions levels. The implant cumulative survival rate, with revision for any reason, was 68.9% at 7 years. CONCLUSIONS: Although medium-sized MoM THA with a 36 mm head has a marginally better survivorship at midterm followup, compared to larger size head MoM articulating THA, our findings nonetheless are still worryingly poor in comparison to what has been quoted in the literature. Furthermore, ARMD-related revision remains the predominant cause of failure in this cohort with medium-sized MoM articulation. No correlation was found between blood metal ions levels and the inclination as well as the version of acetabular component.
format Online
Article
Text
id pubmed-4885293
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-48852932016-06-10 Midterm results of 36 mm metal-on-metal total hip arthroplasty Akrawi, Hawar Hossain, Fahad S Niculescu, Stefan Hashim, Zaid Ng, Arron Biing Shetty, Ajit Indian J Orthop Original Article BACKGROUND: Despite the many perceived benefits of metal-on-metal (MoM) articulation in total hip arthroplasty (THA), there have been growing concerns about metallosis and adverse reaction to metal debris (ARMD). Analysis of size 36 mm MoM articulation THAs is presented. These patients were evaluated for patient characteristics, relationship between blood metal ions levels and the inclination as well as the version of acetabular component, cumulative survival probability at final followup and functional outcome at final followup. MATERIALS AND METHODS: 288, size 36 mm MoM THAs implanted in 269 patients at our institution from 2004 to 2010 were included in this retrospective study. These patients were assessed clinically for hip symptoms, perioperative complications and causes of revision arthroplasty were analysed. Biochemically, blood cobalt and chromium metal ions level were recorded and measurements of acetabular inclination and version were examined. Radiological evaluation utilizing Metal Artefact Reduction Sequence (MARS) MRI was undertaken and implant cumulative survivorship was evaluated. RESULTS: The mean followup was 5 years (range 2–7 years), mean age was 73 years and the mean Oxford hip score was 36.9 (range 5–48). Revision arthroplasty was executed in 20 (7.4%) patients, of which 15 patients underwent single-stage revision THA. The causes of revision arthroplasty were: ARMD changes in 6 (2.2%) patients, infection in 5 (1.9%) patients and aseptic loosening in 5 (1.9%) patients. Three (1.1%) patients had their hips revised for instability, 1 (0.3%) for raised blood metal ions levels. The implant cumulative survival rate, with revision for any reason, was 68.9% at 7 years. CONCLUSIONS: Although medium-sized MoM THA with a 36 mm head has a marginally better survivorship at midterm followup, compared to larger size head MoM articulating THA, our findings nonetheless are still worryingly poor in comparison to what has been quoted in the literature. Furthermore, ARMD-related revision remains the predominant cause of failure in this cohort with medium-sized MoM articulation. No correlation was found between blood metal ions levels and the inclination as well as the version of acetabular component. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC4885293/ /pubmed/27293285 http://dx.doi.org/10.4103/0019-5413.181786 Text en Copyright: © Indian Journal of Orthopaedics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Akrawi, Hawar
Hossain, Fahad S
Niculescu, Stefan
Hashim, Zaid
Ng, Arron Biing
Shetty, Ajit
Midterm results of 36 mm metal-on-metal total hip arthroplasty
title Midterm results of 36 mm metal-on-metal total hip arthroplasty
title_full Midterm results of 36 mm metal-on-metal total hip arthroplasty
title_fullStr Midterm results of 36 mm metal-on-metal total hip arthroplasty
title_full_unstemmed Midterm results of 36 mm metal-on-metal total hip arthroplasty
title_short Midterm results of 36 mm metal-on-metal total hip arthroplasty
title_sort midterm results of 36 mm metal-on-metal total hip arthroplasty
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4885293/
https://www.ncbi.nlm.nih.gov/pubmed/27293285
http://dx.doi.org/10.4103/0019-5413.181786
work_keys_str_mv AT akrawihawar midtermresultsof36mmmetalonmetaltotalhiparthroplasty
AT hossainfahads midtermresultsof36mmmetalonmetaltotalhiparthroplasty
AT niculescustefan midtermresultsof36mmmetalonmetaltotalhiparthroplasty
AT hashimzaid midtermresultsof36mmmetalonmetaltotalhiparthroplasty
AT ngarronbiing midtermresultsof36mmmetalonmetaltotalhiparthroplasty
AT shettyajit midtermresultsof36mmmetalonmetaltotalhiparthroplasty