Cargando…

Validation of inflationary noninvasive blood pressure monitoring in the emergency room

OBJECTIVE: The aim of this study was to compare the values of a noninvasive blood pressure (NIBP) measurement during cuff inflation (inflationary NIBP) and deflationary NIBP measurements and to verify whether inflationary NIBP is equivalent to conventional deflationary NIBP and is acceptable for cli...

Descripción completa

Detalles Bibliográficos
Autores principales: Sasaki, Junichi, Kikuchi, Yoshiharu, Usuda, Takashi, Hori, Shingo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4885524/
https://www.ncbi.nlm.nih.gov/pubmed/26241294
http://dx.doi.org/10.1097/MBP.0000000000000145
_version_ 1782434517394391040
author Sasaki, Junichi
Kikuchi, Yoshiharu
Usuda, Takashi
Hori, Shingo
author_facet Sasaki, Junichi
Kikuchi, Yoshiharu
Usuda, Takashi
Hori, Shingo
author_sort Sasaki, Junichi
collection PubMed
description OBJECTIVE: The aim of this study was to compare the values of a noninvasive blood pressure (NIBP) measurement during cuff inflation (inflationary NIBP) and deflationary NIBP measurements and to verify whether inflationary NIBP is equivalent to conventional deflationary NIBP and is acceptable for clinical use in the emergency room (ER). MATERIALS AND METHODS: A total of 2981 NIBP data points were collected from 175 patients (age, 56.5±22.2 years; range, 7–92 years) who had been treated in the resuscitation area of the ER at Keio University Hospital. The data points were obtained using two alternate algorithms with a standard monitor (BSM-6000). One algorithm consisted of continuous inflationary and deflationary measurements in a single cycle (dual algorithm, 1502 data points); this algorithm was used to verify the success rate and the precision of the data. The second algorithm (1479 data points) consisted of only conventional deflationary measurements and was used to verify the duration of the measurement cycle. RESULTS: The success rate of the inflationary NIBP (completed using only the inflationary method) was 69.0%. Failures in the inflationary measurements were caused by arrhythmia and/or body motions. The mean difference and SD of the systolic pressure and the diastolic pressure between inflationary NIBP and deflationary NIBP were −0.6±8.8 and 3.5±7.5 mmHg, respectively. The confidence intervals were −0.6 (95% confidence interval=−1.1 to −0.1) and 3.5 (95% confidence interval=3.0 to 4.0) mmHg. The coefficients of correlation were 0.96 and 0.93. Inflationary NIBP was capable of determining the NIBP more quickly compared with deflationary NIBP (average of 15.9 vs. 34.2 s; P<0.05). CONCLUSION: Inflationary NIBP measurements have a reasonable accuracy and a sufficient rapidity, compared with deflationary NIBP measurements, in ER patients.
format Online
Article
Text
id pubmed-4885524
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-48855242016-06-15 Validation of inflationary noninvasive blood pressure monitoring in the emergency room Sasaki, Junichi Kikuchi, Yoshiharu Usuda, Takashi Hori, Shingo Blood Press Monit Clinical Methods and Pathophysiology OBJECTIVE: The aim of this study was to compare the values of a noninvasive blood pressure (NIBP) measurement during cuff inflation (inflationary NIBP) and deflationary NIBP measurements and to verify whether inflationary NIBP is equivalent to conventional deflationary NIBP and is acceptable for clinical use in the emergency room (ER). MATERIALS AND METHODS: A total of 2981 NIBP data points were collected from 175 patients (age, 56.5±22.2 years; range, 7–92 years) who had been treated in the resuscitation area of the ER at Keio University Hospital. The data points were obtained using two alternate algorithms with a standard monitor (BSM-6000). One algorithm consisted of continuous inflationary and deflationary measurements in a single cycle (dual algorithm, 1502 data points); this algorithm was used to verify the success rate and the precision of the data. The second algorithm (1479 data points) consisted of only conventional deflationary measurements and was used to verify the duration of the measurement cycle. RESULTS: The success rate of the inflationary NIBP (completed using only the inflationary method) was 69.0%. Failures in the inflationary measurements were caused by arrhythmia and/or body motions. The mean difference and SD of the systolic pressure and the diastolic pressure between inflationary NIBP and deflationary NIBP were −0.6±8.8 and 3.5±7.5 mmHg, respectively. The confidence intervals were −0.6 (95% confidence interval=−1.1 to −0.1) and 3.5 (95% confidence interval=3.0 to 4.0) mmHg. The coefficients of correlation were 0.96 and 0.93. Inflationary NIBP was capable of determining the NIBP more quickly compared with deflationary NIBP (average of 15.9 vs. 34.2 s; P<0.05). CONCLUSION: Inflationary NIBP measurements have a reasonable accuracy and a sufficient rapidity, compared with deflationary NIBP measurements, in ER patients. Lippincott Williams & Wilkins 2015-12 2015-11-09 /pmc/articles/PMC4885524/ /pubmed/26241294 http://dx.doi.org/10.1097/MBP.0000000000000145 Text en Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially.http://creativecommons.org/licenses/by-nc-nd/4.0/.
spellingShingle Clinical Methods and Pathophysiology
Sasaki, Junichi
Kikuchi, Yoshiharu
Usuda, Takashi
Hori, Shingo
Validation of inflationary noninvasive blood pressure monitoring in the emergency room
title Validation of inflationary noninvasive blood pressure monitoring in the emergency room
title_full Validation of inflationary noninvasive blood pressure monitoring in the emergency room
title_fullStr Validation of inflationary noninvasive blood pressure monitoring in the emergency room
title_full_unstemmed Validation of inflationary noninvasive blood pressure monitoring in the emergency room
title_short Validation of inflationary noninvasive blood pressure monitoring in the emergency room
title_sort validation of inflationary noninvasive blood pressure monitoring in the emergency room
topic Clinical Methods and Pathophysiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4885524/
https://www.ncbi.nlm.nih.gov/pubmed/26241294
http://dx.doi.org/10.1097/MBP.0000000000000145
work_keys_str_mv AT sasakijunichi validationofinflationarynoninvasivebloodpressuremonitoringintheemergencyroom
AT kikuchiyoshiharu validationofinflationarynoninvasivebloodpressuremonitoringintheemergencyroom
AT usudatakashi validationofinflationarynoninvasivebloodpressuremonitoringintheemergencyroom
AT horishingo validationofinflationarynoninvasivebloodpressuremonitoringintheemergencyroom