Cargando…

Comparison of noninvasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference

Pulse transit time (PTT) measured as the time delay between invasive proximal and distal blood pressure (BP) or flow waveforms (invasive PTT [I‐PTT]) tightly correlates with BP. PTT estimated as the time delay between noninvasive proximal and distal arterial waveforms could therefore permit cuff‐les...

Descripción completa

Detalles Bibliográficos
Autores principales: Gao, Mingwu, Olivier, N. Bari, Mukkamala, Ramakrishna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4886159/
https://www.ncbi.nlm.nih.gov/pubmed/27233300
http://dx.doi.org/10.14814/phy2.12768
_version_ 1782434588047441920
author Gao, Mingwu
Olivier, N. Bari
Mukkamala, Ramakrishna
author_facet Gao, Mingwu
Olivier, N. Bari
Mukkamala, Ramakrishna
author_sort Gao, Mingwu
collection PubMed
description Pulse transit time (PTT) measured as the time delay between invasive proximal and distal blood pressure (BP) or flow waveforms (invasive PTT [I‐PTT]) tightly correlates with BP. PTT estimated as the time delay between noninvasive proximal and distal arterial waveforms could therefore permit cuff‐less BP monitoring. A popular noninvasive PTT estimate for this application is the time delay between ECG and photoplethysmography (PPG) waveforms (pulse arrival time [PAT]). Another estimate is the time delay between proximal and distal PPG waveforms (PPG‐PTT). PAT and PPG‐PTT were assessed as markers of BP over a wide physiologic range using I‐PTT as a reference. Waveforms for determining I‐PTT, PAT, and PPG‐PTT through central arteries were measured from swine during baseline conditions and infusions of various hemodynamic drugs. Diastolic, mean, and systolic BP varied widely in each subject (group average (mean ± SE) standard deviation between 25 ± 2 and 36 ± 2 mmHg). I‐PTT correlated well with all BP levels (group average R (2) values between 0.86 ± 0.03 and 0.91 ± 0.03). PPG‐PTT also correlated well with all BP levels (group average R (2) values between 0.81 ± 0.03 and 0.85 ± 0.02), and its R (2) values were not significantly different from those of I‐PTT. PAT correlated best with systolic BP (group average R (2) value of 0.70 ± 0.04), but its R (2) values for all BP levels were significantly lower than those of I‐PTT (P < 0.005) and PPG‐PTT (P < 0.02). The pre‐ejection period component of PAT was responsible for its inferior correlation with BP. In sum, PPG‐PTT was not different from I‐PTT and superior to the popular PAT as a marker of BP.
format Online
Article
Text
id pubmed-4886159
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-48861592016-08-17 Comparison of noninvasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference Gao, Mingwu Olivier, N. Bari Mukkamala, Ramakrishna Physiol Rep Original Research Pulse transit time (PTT) measured as the time delay between invasive proximal and distal blood pressure (BP) or flow waveforms (invasive PTT [I‐PTT]) tightly correlates with BP. PTT estimated as the time delay between noninvasive proximal and distal arterial waveforms could therefore permit cuff‐less BP monitoring. A popular noninvasive PTT estimate for this application is the time delay between ECG and photoplethysmography (PPG) waveforms (pulse arrival time [PAT]). Another estimate is the time delay between proximal and distal PPG waveforms (PPG‐PTT). PAT and PPG‐PTT were assessed as markers of BP over a wide physiologic range using I‐PTT as a reference. Waveforms for determining I‐PTT, PAT, and PPG‐PTT through central arteries were measured from swine during baseline conditions and infusions of various hemodynamic drugs. Diastolic, mean, and systolic BP varied widely in each subject (group average (mean ± SE) standard deviation between 25 ± 2 and 36 ± 2 mmHg). I‐PTT correlated well with all BP levels (group average R (2) values between 0.86 ± 0.03 and 0.91 ± 0.03). PPG‐PTT also correlated well with all BP levels (group average R (2) values between 0.81 ± 0.03 and 0.85 ± 0.02), and its R (2) values were not significantly different from those of I‐PTT. PAT correlated best with systolic BP (group average R (2) value of 0.70 ± 0.04), but its R (2) values for all BP levels were significantly lower than those of I‐PTT (P < 0.005) and PPG‐PTT (P < 0.02). The pre‐ejection period component of PAT was responsible for its inferior correlation with BP. In sum, PPG‐PTT was not different from I‐PTT and superior to the popular PAT as a marker of BP. John Wiley and Sons Inc. 2016-05-27 /pmc/articles/PMC4886159/ /pubmed/27233300 http://dx.doi.org/10.14814/phy2.12768 Text en © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Gao, Mingwu
Olivier, N. Bari
Mukkamala, Ramakrishna
Comparison of noninvasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference
title Comparison of noninvasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference
title_full Comparison of noninvasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference
title_fullStr Comparison of noninvasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference
title_full_unstemmed Comparison of noninvasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference
title_short Comparison of noninvasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference
title_sort comparison of noninvasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4886159/
https://www.ncbi.nlm.nih.gov/pubmed/27233300
http://dx.doi.org/10.14814/phy2.12768
work_keys_str_mv AT gaomingwu comparisonofnoninvasivepulsetransittimeestimatesasmarkersofbloodpressureusinginvasivepulsetransittimemeasurementsasareference
AT oliviernbari comparisonofnoninvasivepulsetransittimeestimatesasmarkersofbloodpressureusinginvasivepulsetransittimemeasurementsasareference
AT mukkamalaramakrishna comparisonofnoninvasivepulsetransittimeestimatesasmarkersofbloodpressureusinginvasivepulsetransittimemeasurementsasareference