Cargando…

Effective Bolus Dose of Sufentanil to Attenuate Cardiovascular Responses in Laryngoscopic Double-Lumen Endobronchial Intubation

BACKGROUND: Sufentanil is a potent opioid analgesic frequently used in clinical anesthesia. Double-lumen endobronchial intubation induces profound cardiovascular responses in comparison with ordinary endotracheal intubation because of the larger tube diameter and direct irritation of the carina. OBJ...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Byung-Hee, Lee, Yong-Cheol
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Kowsar 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4886625/
https://www.ncbi.nlm.nih.gov/pubmed/27252903
http://dx.doi.org/10.5812/aapm.33640
_version_ 1782434643279085568
author Choi, Byung-Hee
Lee, Yong-Cheol
author_facet Choi, Byung-Hee
Lee, Yong-Cheol
author_sort Choi, Byung-Hee
collection PubMed
description BACKGROUND: Sufentanil is a potent opioid analgesic frequently used in clinical anesthesia. Double-lumen endobronchial intubation induces profound cardiovascular responses in comparison with ordinary endotracheal intubation because of the larger tube diameter and direct irritation of the carina. OBJECTIVES: The purpose of this study was to determine the effective bolus dose of sufentanil to attenuate hemodynamic changes in response to laryngoscopic double-lumen endobronchial intubation. PATIENTS AND METHODS: We randomly assigned 72 patients aged 18 - 65 years and with an American Society of Anesthesiologists physical status of 1 or 2 to one of four sufentanil dose groups: NS, S0.1, S0.2, or S0.3. The respective doses for the groups were as follows: normal saline, 0.1 mcg/kg of sufentanil, 0.2 mcg/kg of sufentanil, and 0.3 mcg/kg of sufentanil. Blood pressure and heart rate were recorded during the pre-anesthesia period at baseline, pre-intubation, immediate post-intubation, and every minute during 5 minutes after intubation. RESULTS: Baseline mean arterial pressures in the NS, S0.1, S0.2, and S0.3 groups were 89.8 ± 12.1, 89.2 ± 10.9, 88.8 ± 13.6, and 90.7 ± 11.1, respectively. At immediate post-intubation, the mean arterial pressures in the NS, S0.1, S0.2, and S0.3 groups were 129.7 ± 14.7, 120.7 ± 14.2, 120.8 ± 17.2, and 96.7 ± 10.4, respectively. At immediate post-intubation, the mean arterial pressure in the NS, S0.1, and S0.2 groups significantly increased from baseline (P < 0.001), but the S0.3 group showed no difference. In the time point comparison at immediate post- intubation, the S0.3 group had a significantly lower mean arterial pressure than did the NS, S0.1, and S0.2 groups (P < 0.001). CONCLUSIONS: We found that 0.3 mcg/kg of sufentanil attenuates cardiovascular responses to double-lumen endobronchial intubation without adverse effects.
format Online
Article
Text
id pubmed-4886625
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Kowsar
record_format MEDLINE/PubMed
spelling pubmed-48866252016-06-01 Effective Bolus Dose of Sufentanil to Attenuate Cardiovascular Responses in Laryngoscopic Double-Lumen Endobronchial Intubation Choi, Byung-Hee Lee, Yong-Cheol Anesth Pain Med Research Article BACKGROUND: Sufentanil is a potent opioid analgesic frequently used in clinical anesthesia. Double-lumen endobronchial intubation induces profound cardiovascular responses in comparison with ordinary endotracheal intubation because of the larger tube diameter and direct irritation of the carina. OBJECTIVES: The purpose of this study was to determine the effective bolus dose of sufentanil to attenuate hemodynamic changes in response to laryngoscopic double-lumen endobronchial intubation. PATIENTS AND METHODS: We randomly assigned 72 patients aged 18 - 65 years and with an American Society of Anesthesiologists physical status of 1 or 2 to one of four sufentanil dose groups: NS, S0.1, S0.2, or S0.3. The respective doses for the groups were as follows: normal saline, 0.1 mcg/kg of sufentanil, 0.2 mcg/kg of sufentanil, and 0.3 mcg/kg of sufentanil. Blood pressure and heart rate were recorded during the pre-anesthesia period at baseline, pre-intubation, immediate post-intubation, and every minute during 5 minutes after intubation. RESULTS: Baseline mean arterial pressures in the NS, S0.1, S0.2, and S0.3 groups were 89.8 ± 12.1, 89.2 ± 10.9, 88.8 ± 13.6, and 90.7 ± 11.1, respectively. At immediate post-intubation, the mean arterial pressures in the NS, S0.1, S0.2, and S0.3 groups were 129.7 ± 14.7, 120.7 ± 14.2, 120.8 ± 17.2, and 96.7 ± 10.4, respectively. At immediate post-intubation, the mean arterial pressure in the NS, S0.1, and S0.2 groups significantly increased from baseline (P < 0.001), but the S0.3 group showed no difference. In the time point comparison at immediate post- intubation, the S0.3 group had a significantly lower mean arterial pressure than did the NS, S0.1, and S0.2 groups (P < 0.001). CONCLUSIONS: We found that 0.3 mcg/kg of sufentanil attenuates cardiovascular responses to double-lumen endobronchial intubation without adverse effects. Kowsar 2016-04-04 /pmc/articles/PMC4886625/ /pubmed/27252903 http://dx.doi.org/10.5812/aapm.33640 Text en Copyright © 2016, Iranian Society of Regional Anesthesia and Pain Medicine (ISRAPM) http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited.
spellingShingle Research Article
Choi, Byung-Hee
Lee, Yong-Cheol
Effective Bolus Dose of Sufentanil to Attenuate Cardiovascular Responses in Laryngoscopic Double-Lumen Endobronchial Intubation
title Effective Bolus Dose of Sufentanil to Attenuate Cardiovascular Responses in Laryngoscopic Double-Lumen Endobronchial Intubation
title_full Effective Bolus Dose of Sufentanil to Attenuate Cardiovascular Responses in Laryngoscopic Double-Lumen Endobronchial Intubation
title_fullStr Effective Bolus Dose of Sufentanil to Attenuate Cardiovascular Responses in Laryngoscopic Double-Lumen Endobronchial Intubation
title_full_unstemmed Effective Bolus Dose of Sufentanil to Attenuate Cardiovascular Responses in Laryngoscopic Double-Lumen Endobronchial Intubation
title_short Effective Bolus Dose of Sufentanil to Attenuate Cardiovascular Responses in Laryngoscopic Double-Lumen Endobronchial Intubation
title_sort effective bolus dose of sufentanil to attenuate cardiovascular responses in laryngoscopic double-lumen endobronchial intubation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4886625/
https://www.ncbi.nlm.nih.gov/pubmed/27252903
http://dx.doi.org/10.5812/aapm.33640
work_keys_str_mv AT choibyunghee effectivebolusdoseofsufentaniltoattenuatecardiovascularresponsesinlaryngoscopicdoublelumenendobronchialintubation
AT leeyongcheol effectivebolusdoseofsufentaniltoattenuatecardiovascularresponsesinlaryngoscopicdoublelumenendobronchialintubation