Cargando…
Effective Bolus Dose of Sufentanil to Attenuate Cardiovascular Responses in Laryngoscopic Double-Lumen Endobronchial Intubation
BACKGROUND: Sufentanil is a potent opioid analgesic frequently used in clinical anesthesia. Double-lumen endobronchial intubation induces profound cardiovascular responses in comparison with ordinary endotracheal intubation because of the larger tube diameter and direct irritation of the carina. OBJ...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Kowsar
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4886625/ https://www.ncbi.nlm.nih.gov/pubmed/27252903 http://dx.doi.org/10.5812/aapm.33640 |
_version_ | 1782434643279085568 |
---|---|
author | Choi, Byung-Hee Lee, Yong-Cheol |
author_facet | Choi, Byung-Hee Lee, Yong-Cheol |
author_sort | Choi, Byung-Hee |
collection | PubMed |
description | BACKGROUND: Sufentanil is a potent opioid analgesic frequently used in clinical anesthesia. Double-lumen endobronchial intubation induces profound cardiovascular responses in comparison with ordinary endotracheal intubation because of the larger tube diameter and direct irritation of the carina. OBJECTIVES: The purpose of this study was to determine the effective bolus dose of sufentanil to attenuate hemodynamic changes in response to laryngoscopic double-lumen endobronchial intubation. PATIENTS AND METHODS: We randomly assigned 72 patients aged 18 - 65 years and with an American Society of Anesthesiologists physical status of 1 or 2 to one of four sufentanil dose groups: NS, S0.1, S0.2, or S0.3. The respective doses for the groups were as follows: normal saline, 0.1 mcg/kg of sufentanil, 0.2 mcg/kg of sufentanil, and 0.3 mcg/kg of sufentanil. Blood pressure and heart rate were recorded during the pre-anesthesia period at baseline, pre-intubation, immediate post-intubation, and every minute during 5 minutes after intubation. RESULTS: Baseline mean arterial pressures in the NS, S0.1, S0.2, and S0.3 groups were 89.8 ± 12.1, 89.2 ± 10.9, 88.8 ± 13.6, and 90.7 ± 11.1, respectively. At immediate post-intubation, the mean arterial pressures in the NS, S0.1, S0.2, and S0.3 groups were 129.7 ± 14.7, 120.7 ± 14.2, 120.8 ± 17.2, and 96.7 ± 10.4, respectively. At immediate post-intubation, the mean arterial pressure in the NS, S0.1, and S0.2 groups significantly increased from baseline (P < 0.001), but the S0.3 group showed no difference. In the time point comparison at immediate post- intubation, the S0.3 group had a significantly lower mean arterial pressure than did the NS, S0.1, and S0.2 groups (P < 0.001). CONCLUSIONS: We found that 0.3 mcg/kg of sufentanil attenuates cardiovascular responses to double-lumen endobronchial intubation without adverse effects. |
format | Online Article Text |
id | pubmed-4886625 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Kowsar |
record_format | MEDLINE/PubMed |
spelling | pubmed-48866252016-06-01 Effective Bolus Dose of Sufentanil to Attenuate Cardiovascular Responses in Laryngoscopic Double-Lumen Endobronchial Intubation Choi, Byung-Hee Lee, Yong-Cheol Anesth Pain Med Research Article BACKGROUND: Sufentanil is a potent opioid analgesic frequently used in clinical anesthesia. Double-lumen endobronchial intubation induces profound cardiovascular responses in comparison with ordinary endotracheal intubation because of the larger tube diameter and direct irritation of the carina. OBJECTIVES: The purpose of this study was to determine the effective bolus dose of sufentanil to attenuate hemodynamic changes in response to laryngoscopic double-lumen endobronchial intubation. PATIENTS AND METHODS: We randomly assigned 72 patients aged 18 - 65 years and with an American Society of Anesthesiologists physical status of 1 or 2 to one of four sufentanil dose groups: NS, S0.1, S0.2, or S0.3. The respective doses for the groups were as follows: normal saline, 0.1 mcg/kg of sufentanil, 0.2 mcg/kg of sufentanil, and 0.3 mcg/kg of sufentanil. Blood pressure and heart rate were recorded during the pre-anesthesia period at baseline, pre-intubation, immediate post-intubation, and every minute during 5 minutes after intubation. RESULTS: Baseline mean arterial pressures in the NS, S0.1, S0.2, and S0.3 groups were 89.8 ± 12.1, 89.2 ± 10.9, 88.8 ± 13.6, and 90.7 ± 11.1, respectively. At immediate post-intubation, the mean arterial pressures in the NS, S0.1, S0.2, and S0.3 groups were 129.7 ± 14.7, 120.7 ± 14.2, 120.8 ± 17.2, and 96.7 ± 10.4, respectively. At immediate post-intubation, the mean arterial pressure in the NS, S0.1, and S0.2 groups significantly increased from baseline (P < 0.001), but the S0.3 group showed no difference. In the time point comparison at immediate post- intubation, the S0.3 group had a significantly lower mean arterial pressure than did the NS, S0.1, and S0.2 groups (P < 0.001). CONCLUSIONS: We found that 0.3 mcg/kg of sufentanil attenuates cardiovascular responses to double-lumen endobronchial intubation without adverse effects. Kowsar 2016-04-04 /pmc/articles/PMC4886625/ /pubmed/27252903 http://dx.doi.org/10.5812/aapm.33640 Text en Copyright © 2016, Iranian Society of Regional Anesthesia and Pain Medicine (ISRAPM) http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited. |
spellingShingle | Research Article Choi, Byung-Hee Lee, Yong-Cheol Effective Bolus Dose of Sufentanil to Attenuate Cardiovascular Responses in Laryngoscopic Double-Lumen Endobronchial Intubation |
title | Effective Bolus Dose of Sufentanil to Attenuate Cardiovascular Responses in Laryngoscopic Double-Lumen Endobronchial Intubation |
title_full | Effective Bolus Dose of Sufentanil to Attenuate Cardiovascular Responses in Laryngoscopic Double-Lumen Endobronchial Intubation |
title_fullStr | Effective Bolus Dose of Sufentanil to Attenuate Cardiovascular Responses in Laryngoscopic Double-Lumen Endobronchial Intubation |
title_full_unstemmed | Effective Bolus Dose of Sufentanil to Attenuate Cardiovascular Responses in Laryngoscopic Double-Lumen Endobronchial Intubation |
title_short | Effective Bolus Dose of Sufentanil to Attenuate Cardiovascular Responses in Laryngoscopic Double-Lumen Endobronchial Intubation |
title_sort | effective bolus dose of sufentanil to attenuate cardiovascular responses in laryngoscopic double-lumen endobronchial intubation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4886625/ https://www.ncbi.nlm.nih.gov/pubmed/27252903 http://dx.doi.org/10.5812/aapm.33640 |
work_keys_str_mv | AT choibyunghee effectivebolusdoseofsufentaniltoattenuatecardiovascularresponsesinlaryngoscopicdoublelumenendobronchialintubation AT leeyongcheol effectivebolusdoseofsufentaniltoattenuatecardiovascularresponsesinlaryngoscopicdoublelumenendobronchialintubation |