Nasal highflow improves ventilation in patients with COPD

BACKGROUND: Nasal highflow (NHF) provides a warmed and humidified air stream up to 60 L/min. Recent data demonstrated a positive effect in patients with acute hypoxemic respiratory failure, especially when caused by pneumonia. Preliminary data show a decrease in hypercapnia in patients with COPD. Th...

Descripción completa

Detalles Bibliográficos
Autores principales: Bräunlich, Jens, Köhler, Marcus, Wirtz, Hubert
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4887061/
https://www.ncbi.nlm.nih.gov/pubmed/27307723
http://dx.doi.org/10.2147/COPD.S104616
_version_ 1782434690980904960
author Bräunlich, Jens
Köhler, Marcus
Wirtz, Hubert
author_facet Bräunlich, Jens
Köhler, Marcus
Wirtz, Hubert
author_sort Bräunlich, Jens
collection PubMed
description BACKGROUND: Nasal highflow (NHF) provides a warmed and humidified air stream up to 60 L/min. Recent data demonstrated a positive effect in patients with acute hypoxemic respiratory failure, especially when caused by pneumonia. Preliminary data show a decrease in hypercapnia in patients with COPD. Therefore, NHF should be evaluated as a new ventilatory support device. This study was conducted to assess the impact of different flow rates on ventilatory parameters in patients with COPD. MATERIALS AND METHODS: This interventional clinical study was performed with patients suffering from severe COPD. The aim was to characterize flow-dependent changes in mean airway pressure, breathing volumes, breathing frequency, and decrease in partial pressure of CO(2) (pCO(2)). Mean airway pressure was measured in the nasopharyngeal space (19 patients). To evaluate breathing volumes, we used a polysomnographic device (18 patients). All patients received 20 L/min, 30 L/min, 40 L/min, and 50 L/min and – to illustrate the effects – nasal continuous positive airway pressure and nasal bilevel positive airway pressure. Capillary blood gas analyses were performed in 54 patients with hypercapnic COPD before and two hours after the use of NHF. We compared the extent of decrease in pCO(2) when using 20 L/min and 30 L/min. Additionally, comfort and dyspnea during the use of NHF were surveyed. RESULTS: NHF resulted in a minor flow dependent increase in mean airway pressure. Tidal volume increased, and breathing rate decreased. The calculated minute volume decreased under NHF breathing. In spite of this fact, hypercapnia decreased with increasing flow (20 L/min vs 30 L/min). Additionally, an improvement in dyspnea was observed. The rapid shallow breathing index shows a decrease when using NHF. CONCLUSION: NHF leads to a flow-dependent reduction in pCO(2). This is most likely achieved by a washout of the respiratory tract and a functional reduction in dead space. In summary, NHF enhances effectiveness of breathing in patients with COPD, reduces pCO(2), the work of breathing, and rapid shallow breathing index as an indicator of respiratory work load.
format Online
Article
Text
id pubmed-4887061
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-48870612016-06-15 Nasal highflow improves ventilation in patients with COPD Bräunlich, Jens Köhler, Marcus Wirtz, Hubert Int J Chron Obstruct Pulmon Dis Original Research BACKGROUND: Nasal highflow (NHF) provides a warmed and humidified air stream up to 60 L/min. Recent data demonstrated a positive effect in patients with acute hypoxemic respiratory failure, especially when caused by pneumonia. Preliminary data show a decrease in hypercapnia in patients with COPD. Therefore, NHF should be evaluated as a new ventilatory support device. This study was conducted to assess the impact of different flow rates on ventilatory parameters in patients with COPD. MATERIALS AND METHODS: This interventional clinical study was performed with patients suffering from severe COPD. The aim was to characterize flow-dependent changes in mean airway pressure, breathing volumes, breathing frequency, and decrease in partial pressure of CO(2) (pCO(2)). Mean airway pressure was measured in the nasopharyngeal space (19 patients). To evaluate breathing volumes, we used a polysomnographic device (18 patients). All patients received 20 L/min, 30 L/min, 40 L/min, and 50 L/min and – to illustrate the effects – nasal continuous positive airway pressure and nasal bilevel positive airway pressure. Capillary blood gas analyses were performed in 54 patients with hypercapnic COPD before and two hours after the use of NHF. We compared the extent of decrease in pCO(2) when using 20 L/min and 30 L/min. Additionally, comfort and dyspnea during the use of NHF were surveyed. RESULTS: NHF resulted in a minor flow dependent increase in mean airway pressure. Tidal volume increased, and breathing rate decreased. The calculated minute volume decreased under NHF breathing. In spite of this fact, hypercapnia decreased with increasing flow (20 L/min vs 30 L/min). Additionally, an improvement in dyspnea was observed. The rapid shallow breathing index shows a decrease when using NHF. CONCLUSION: NHF leads to a flow-dependent reduction in pCO(2). This is most likely achieved by a washout of the respiratory tract and a functional reduction in dead space. In summary, NHF enhances effectiveness of breathing in patients with COPD, reduces pCO(2), the work of breathing, and rapid shallow breathing index as an indicator of respiratory work load. Dove Medical Press 2016-05-25 /pmc/articles/PMC4887061/ /pubmed/27307723 http://dx.doi.org/10.2147/COPD.S104616 Text en © 2016 Bräunlich et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Bräunlich, Jens
Köhler, Marcus
Wirtz, Hubert
Nasal highflow improves ventilation in patients with COPD
title Nasal highflow improves ventilation in patients with COPD
title_full Nasal highflow improves ventilation in patients with COPD
title_fullStr Nasal highflow improves ventilation in patients with COPD
title_full_unstemmed Nasal highflow improves ventilation in patients with COPD
title_short Nasal highflow improves ventilation in patients with COPD
title_sort nasal highflow improves ventilation in patients with copd
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4887061/
https://www.ncbi.nlm.nih.gov/pubmed/27307723
http://dx.doi.org/10.2147/COPD.S104616
work_keys_str_mv AT braunlichjens nasalhighflowimprovesventilationinpatientswithcopd
AT kohlermarcus nasalhighflowimprovesventilationinpatientswithcopd
AT wirtzhubert nasalhighflowimprovesventilationinpatientswithcopd