Determining the Magnetic Properties of 1 kg Mass Standards

Magnetic interactions may lead to errors in precision mass metrology. An analytical description of such magnetic errors is presented in which the roles of both the volume magnetic susceptibility and permanent magnetization are discussed. The same formalism is then used to describe in detail the cali...

Descripción completa

Detalles Bibliográficos
Autor principal: Davis, Richard S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1995
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4887247/
https://www.ncbi.nlm.nih.gov/pubmed/29151735
http://dx.doi.org/10.6028/jres.100.015
_version_ 1782434711657775104
author Davis, Richard S.
author_facet Davis, Richard S.
author_sort Davis, Richard S.
collection PubMed
description Magnetic interactions may lead to errors in precision mass metrology. An analytical description of such magnetic errors is presented in which the roles of both the volume magnetic susceptibility and permanent magnetization are discussed. The same formalism is then used to describe in detail the calibration and operation of a susceptometer developed at the Bureau International des Poids et Mesures (BIPM). The device has been optimized for the determination of the magnetic properties of 1 kg mass standards.
format Online
Article
Text
id pubmed-4887247
institution National Center for Biotechnology Information
language English
publishDate 1995
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-48872472017-11-17 Determining the Magnetic Properties of 1 kg Mass Standards Davis, Richard S. J Res Natl Inst Stand Technol Article Magnetic interactions may lead to errors in precision mass metrology. An analytical description of such magnetic errors is presented in which the roles of both the volume magnetic susceptibility and permanent magnetization are discussed. The same formalism is then used to describe in detail the calibration and operation of a susceptometer developed at the Bureau International des Poids et Mesures (BIPM). The device has been optimized for the determination of the magnetic properties of 1 kg mass standards. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1995 /pmc/articles/PMC4887247/ /pubmed/29151735 http://dx.doi.org/10.6028/jres.100.015 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Davis, Richard S.
Determining the Magnetic Properties of 1 kg Mass Standards
title Determining the Magnetic Properties of 1 kg Mass Standards
title_full Determining the Magnetic Properties of 1 kg Mass Standards
title_fullStr Determining the Magnetic Properties of 1 kg Mass Standards
title_full_unstemmed Determining the Magnetic Properties of 1 kg Mass Standards
title_short Determining the Magnetic Properties of 1 kg Mass Standards
title_sort determining the magnetic properties of 1 kg mass standards
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4887247/
https://www.ncbi.nlm.nih.gov/pubmed/29151735
http://dx.doi.org/10.6028/jres.100.015
work_keys_str_mv AT davisrichards determiningthemagneticpropertiesof1kgmassstandards