Cargando…

Development of Magnetorheological Resistive Exercise Device for Rowing Machine

Training equipment used by professional sportsmen has a great impact on their sport performance. Most universal exercisers may help only to improve the general physical condition due to the specific kinematics and peculiar resistance generated by their loading units. Training of effective techniques...

Descripción completa

Detalles Bibliográficos
Autores principales: Grigas, Vytautas, Šulginas, Anatolijus, Žiliukas, Pranas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4887648/
https://www.ncbi.nlm.nih.gov/pubmed/27293479
http://dx.doi.org/10.1155/2016/8979070
_version_ 1782434761474572288
author Grigas, Vytautas
Šulginas, Anatolijus
Žiliukas, Pranas
author_facet Grigas, Vytautas
Šulginas, Anatolijus
Žiliukas, Pranas
author_sort Grigas, Vytautas
collection PubMed
description Training equipment used by professional sportsmen has a great impact on their sport performance. Most universal exercisers may help only to improve the general physical condition due to the specific kinematics and peculiar resistance generated by their loading units. Training of effective techniques and learning of psychomotor skills are possible only when exercisers conform to the movements and resistance typical for particular sports kinematically and dynamically. Methodology of developing a magnetorheological resistive exercise device for generating the desired law of passive resistance force and its application in a lever-type rowing machine are described in the paper. The structural parameters of a controllable hydraulic cylinder type device were found by means of the computational fluid dynamics simulation performed by ANSYS CFX software. Parameters describing the magnetorheological fluid as non-Newtonian were determined by combining numerical and experimental research of the resistance force generated by the original magnetorheological damper. A structural scheme of the device control system was developed and the variation of the strength of magnetic field that affects the magnetorheological fluid circulating in the device was determined, ensuring a variation of the resistance force on the oar handle adequate for the resistance that occurs during a real boat rowing stroke.
format Online
Article
Text
id pubmed-4887648
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-48876482016-06-12 Development of Magnetorheological Resistive Exercise Device for Rowing Machine Grigas, Vytautas Šulginas, Anatolijus Žiliukas, Pranas Comput Math Methods Med Research Article Training equipment used by professional sportsmen has a great impact on their sport performance. Most universal exercisers may help only to improve the general physical condition due to the specific kinematics and peculiar resistance generated by their loading units. Training of effective techniques and learning of psychomotor skills are possible only when exercisers conform to the movements and resistance typical for particular sports kinematically and dynamically. Methodology of developing a magnetorheological resistive exercise device for generating the desired law of passive resistance force and its application in a lever-type rowing machine are described in the paper. The structural parameters of a controllable hydraulic cylinder type device were found by means of the computational fluid dynamics simulation performed by ANSYS CFX software. Parameters describing the magnetorheological fluid as non-Newtonian were determined by combining numerical and experimental research of the resistance force generated by the original magnetorheological damper. A structural scheme of the device control system was developed and the variation of the strength of magnetic field that affects the magnetorheological fluid circulating in the device was determined, ensuring a variation of the resistance force on the oar handle adequate for the resistance that occurs during a real boat rowing stroke. Hindawi Publishing Corporation 2016 2016-05-18 /pmc/articles/PMC4887648/ /pubmed/27293479 http://dx.doi.org/10.1155/2016/8979070 Text en Copyright © 2016 Vytautas Grigas et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Grigas, Vytautas
Šulginas, Anatolijus
Žiliukas, Pranas
Development of Magnetorheological Resistive Exercise Device for Rowing Machine
title Development of Magnetorheological Resistive Exercise Device for Rowing Machine
title_full Development of Magnetorheological Resistive Exercise Device for Rowing Machine
title_fullStr Development of Magnetorheological Resistive Exercise Device for Rowing Machine
title_full_unstemmed Development of Magnetorheological Resistive Exercise Device for Rowing Machine
title_short Development of Magnetorheological Resistive Exercise Device for Rowing Machine
title_sort development of magnetorheological resistive exercise device for rowing machine
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4887648/
https://www.ncbi.nlm.nih.gov/pubmed/27293479
http://dx.doi.org/10.1155/2016/8979070
work_keys_str_mv AT grigasvytautas developmentofmagnetorheologicalresistiveexercisedeviceforrowingmachine
AT sulginasanatolijus developmentofmagnetorheologicalresistiveexercisedeviceforrowingmachine
AT ziliukaspranas developmentofmagnetorheologicalresistiveexercisedeviceforrowingmachine