Cargando…

Development of a Bolometer Detector System for the NIST High Accuracy Infrared Spectrophotometer

A bolometer detector system was developed for the high accuracy infrared spectrophotometer at the National Institute of Standards and Technology to provide maximum sensitivity, spatial uniformity, and linearity of response covering the entire infrared spectral range. The spatial response variation w...

Descripción completa

Detalles Bibliográficos
Autores principales: Zong, Y., Datla, R. U.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1998
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4890956/
https://www.ncbi.nlm.nih.gov/pubmed/28009364
http://dx.doi.org/10.6028/jres.103.039
_version_ 1782435192620711936
author Zong, Y.
Datla, R. U.
author_facet Zong, Y.
Datla, R. U.
author_sort Zong, Y.
collection PubMed
description A bolometer detector system was developed for the high accuracy infrared spectrophotometer at the National Institute of Standards and Technology to provide maximum sensitivity, spatial uniformity, and linearity of response covering the entire infrared spectral range. The spatial response variation was measured to be within 0.1 %. The linearity of the detector output was measured over three decades of input power. After applying a simple correction procedure, the detector output was found to deviate less than 0.2 % from linear behavior over this range. The noise equivalent power (NEP) of the bolometer system was 6 × 10(−12) [Formula: see text] at the frequency of 80 Hz. The detector output 3 dB roll-off frequency was 200 Hz. The detector output was stable to within ± 0.05 % over a 15 min period. These results demonstrate that the bolometer detector system will serve as an excellent detector for the high accuracy infrared spectrophotometer.
format Online
Article
Text
id pubmed-4890956
institution National Center for Biotechnology Information
language English
publishDate 1998
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-48909562016-12-22 Development of a Bolometer Detector System for the NIST High Accuracy Infrared Spectrophotometer Zong, Y. Datla, R. U. J Res Natl Inst Stand Technol Article A bolometer detector system was developed for the high accuracy infrared spectrophotometer at the National Institute of Standards and Technology to provide maximum sensitivity, spatial uniformity, and linearity of response covering the entire infrared spectral range. The spatial response variation was measured to be within 0.1 %. The linearity of the detector output was measured over three decades of input power. After applying a simple correction procedure, the detector output was found to deviate less than 0.2 % from linear behavior over this range. The noise equivalent power (NEP) of the bolometer system was 6 × 10(−12) [Formula: see text] at the frequency of 80 Hz. The detector output 3 dB roll-off frequency was 200 Hz. The detector output was stable to within ± 0.05 % over a 15 min period. These results demonstrate that the bolometer detector system will serve as an excellent detector for the high accuracy infrared spectrophotometer. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1998 1998-12-01 /pmc/articles/PMC4890956/ /pubmed/28009364 http://dx.doi.org/10.6028/jres.103.039 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Zong, Y.
Datla, R. U.
Development of a Bolometer Detector System for the NIST High Accuracy Infrared Spectrophotometer
title Development of a Bolometer Detector System for the NIST High Accuracy Infrared Spectrophotometer
title_full Development of a Bolometer Detector System for the NIST High Accuracy Infrared Spectrophotometer
title_fullStr Development of a Bolometer Detector System for the NIST High Accuracy Infrared Spectrophotometer
title_full_unstemmed Development of a Bolometer Detector System for the NIST High Accuracy Infrared Spectrophotometer
title_short Development of a Bolometer Detector System for the NIST High Accuracy Infrared Spectrophotometer
title_sort development of a bolometer detector system for the nist high accuracy infrared spectrophotometer
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4890956/
https://www.ncbi.nlm.nih.gov/pubmed/28009364
http://dx.doi.org/10.6028/jres.103.039
work_keys_str_mv AT zongy developmentofabolometerdetectorsystemforthenisthighaccuracyinfraredspectrophotometer
AT datlaru developmentofabolometerdetectorsystemforthenisthighaccuracyinfraredspectrophotometer