Cargando…

Measurement of Electroretinograms and Visually Evoked Potentials in Awake Moving Mice

The development of new treatments for intractable retinal diseases requires reliable functional assessment tools for animal models. In vivo measurements of neural activity within visual pathways, including electroretinogram (ERG) and visually evoked potential (VEP) recordings, are commonly used for...

Descripción completa

Detalles Bibliográficos
Autores principales: Tomiyama, Yusuke, Fujita, Kosuke, Nishiguchi, Koji M., Tokashiki, Naoyuki, Daigaku, Reiko, Tabata, Kitako, Sugano, Eriko, Tomita, Hiroshi, Nakazawa, Toru
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4892628/
https://www.ncbi.nlm.nih.gov/pubmed/27257864
http://dx.doi.org/10.1371/journal.pone.0156927
_version_ 1782435426963816448
author Tomiyama, Yusuke
Fujita, Kosuke
Nishiguchi, Koji M.
Tokashiki, Naoyuki
Daigaku, Reiko
Tabata, Kitako
Sugano, Eriko
Tomita, Hiroshi
Nakazawa, Toru
author_facet Tomiyama, Yusuke
Fujita, Kosuke
Nishiguchi, Koji M.
Tokashiki, Naoyuki
Daigaku, Reiko
Tabata, Kitako
Sugano, Eriko
Tomita, Hiroshi
Nakazawa, Toru
author_sort Tomiyama, Yusuke
collection PubMed
description The development of new treatments for intractable retinal diseases requires reliable functional assessment tools for animal models. In vivo measurements of neural activity within visual pathways, including electroretinogram (ERG) and visually evoked potential (VEP) recordings, are commonly used for such purposes. In mice, the ERG and VEPs are usually recorded under general anesthesia, a state that may alter sensory transduction and neurotransmission, but seldom in awake freely moving mice. Therefore, it remains unknown whether the electrophysiological assessment of anesthetized mice accurately reflects the physiological function of the visual pathway. Herein, we describe a novel method to record the ERG and VEPs simultaneously in freely moving mice by immobilizing the head using a custom-built restraining device and placing a rotatable cylinder underneath to allow free running or walking during recording. Injection of the commonly used anesthetic mixture xylazine plus ketamine increased and delayed ERG oscillatory potentials by an average of 67.5% and 36.3%, respectively, compared to unanesthetized mice, while having minimal effects on the a-wave and b-wave. Similarly, components of the VEP were enhanced and delayed by up to 300.2% and 39.3%, respectively, in anesthetized mice. Our method for electrophysiological recording in conscious mice is a sensitive and robust means to assess visual function. It uses a conventional electrophysiological recording system and a simple platform that can be built in any laboratory at low cost. Measurements using this method provide objective indices of mouse visual function with high precision and stability, unaffected by anesthetics.
format Online
Article
Text
id pubmed-4892628
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-48926282016-06-16 Measurement of Electroretinograms and Visually Evoked Potentials in Awake Moving Mice Tomiyama, Yusuke Fujita, Kosuke Nishiguchi, Koji M. Tokashiki, Naoyuki Daigaku, Reiko Tabata, Kitako Sugano, Eriko Tomita, Hiroshi Nakazawa, Toru PLoS One Research Article The development of new treatments for intractable retinal diseases requires reliable functional assessment tools for animal models. In vivo measurements of neural activity within visual pathways, including electroretinogram (ERG) and visually evoked potential (VEP) recordings, are commonly used for such purposes. In mice, the ERG and VEPs are usually recorded under general anesthesia, a state that may alter sensory transduction and neurotransmission, but seldom in awake freely moving mice. Therefore, it remains unknown whether the electrophysiological assessment of anesthetized mice accurately reflects the physiological function of the visual pathway. Herein, we describe a novel method to record the ERG and VEPs simultaneously in freely moving mice by immobilizing the head using a custom-built restraining device and placing a rotatable cylinder underneath to allow free running or walking during recording. Injection of the commonly used anesthetic mixture xylazine plus ketamine increased and delayed ERG oscillatory potentials by an average of 67.5% and 36.3%, respectively, compared to unanesthetized mice, while having minimal effects on the a-wave and b-wave. Similarly, components of the VEP were enhanced and delayed by up to 300.2% and 39.3%, respectively, in anesthetized mice. Our method for electrophysiological recording in conscious mice is a sensitive and robust means to assess visual function. It uses a conventional electrophysiological recording system and a simple platform that can be built in any laboratory at low cost. Measurements using this method provide objective indices of mouse visual function with high precision and stability, unaffected by anesthetics. Public Library of Science 2016-06-03 /pmc/articles/PMC4892628/ /pubmed/27257864 http://dx.doi.org/10.1371/journal.pone.0156927 Text en © 2016 Tomiyama et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Tomiyama, Yusuke
Fujita, Kosuke
Nishiguchi, Koji M.
Tokashiki, Naoyuki
Daigaku, Reiko
Tabata, Kitako
Sugano, Eriko
Tomita, Hiroshi
Nakazawa, Toru
Measurement of Electroretinograms and Visually Evoked Potentials in Awake Moving Mice
title Measurement of Electroretinograms and Visually Evoked Potentials in Awake Moving Mice
title_full Measurement of Electroretinograms and Visually Evoked Potentials in Awake Moving Mice
title_fullStr Measurement of Electroretinograms and Visually Evoked Potentials in Awake Moving Mice
title_full_unstemmed Measurement of Electroretinograms and Visually Evoked Potentials in Awake Moving Mice
title_short Measurement of Electroretinograms and Visually Evoked Potentials in Awake Moving Mice
title_sort measurement of electroretinograms and visually evoked potentials in awake moving mice
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4892628/
https://www.ncbi.nlm.nih.gov/pubmed/27257864
http://dx.doi.org/10.1371/journal.pone.0156927
work_keys_str_mv AT tomiyamayusuke measurementofelectroretinogramsandvisuallyevokedpotentialsinawakemovingmice
AT fujitakosuke measurementofelectroretinogramsandvisuallyevokedpotentialsinawakemovingmice
AT nishiguchikojim measurementofelectroretinogramsandvisuallyevokedpotentialsinawakemovingmice
AT tokashikinaoyuki measurementofelectroretinogramsandvisuallyevokedpotentialsinawakemovingmice
AT daigakureiko measurementofelectroretinogramsandvisuallyevokedpotentialsinawakemovingmice
AT tabatakitako measurementofelectroretinogramsandvisuallyevokedpotentialsinawakemovingmice
AT suganoeriko measurementofelectroretinogramsandvisuallyevokedpotentialsinawakemovingmice
AT tomitahiroshi measurementofelectroretinogramsandvisuallyevokedpotentialsinawakemovingmice
AT nakazawatoru measurementofelectroretinogramsandvisuallyevokedpotentialsinawakemovingmice