Cargando…

Effects of R-Phase on Mechanical Responses of a Nickel-Titanium Endodontic Instrument: Structural Characterization and Finite Element Analysis

The effects of the presence of the R-phase in a near-equiatomic NiTi alloy on the mechanical responses of an endodontic instrument were studied by using finite element analysis. The input data for the constitutive model in the simulation were obtained by tensile testing of three NiTi wires: superela...

Descripción completa

Detalles Bibliográficos
Autores principales: Santos, Leandro de Arruda, Resende, Pedro Damas, Bahia, Maria Guiomar de Azevedo, Buono, Vicente Tadeu Lopes
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4893430/
https://www.ncbi.nlm.nih.gov/pubmed/27314059
http://dx.doi.org/10.1155/2016/7617493
_version_ 1782435554613264384
author Santos, Leandro de Arruda
Resende, Pedro Damas
Bahia, Maria Guiomar de Azevedo
Buono, Vicente Tadeu Lopes
author_facet Santos, Leandro de Arruda
Resende, Pedro Damas
Bahia, Maria Guiomar de Azevedo
Buono, Vicente Tadeu Lopes
author_sort Santos, Leandro de Arruda
collection PubMed
description The effects of the presence of the R-phase in a near-equiatomic NiTi alloy on the mechanical responses of an endodontic instrument were studied by using finite element analysis. The input data for the constitutive model in the simulation were obtained by tensile testing of three NiTi wires: superelastic austenite NiTi, austenite + R-phase NiTi, and fully R-phased NiTi. The wires were also characterized by X-ray diffraction and differential scanning calorimetry. A commercially available endodontic instrument was scanned using microcomputed tomography, and the resulting images were used to build the geometrical model. The numerical analyses were performed in ABAQUS using load and boundary conditions based on the ISO 3630-1 specification for the bending and torsion of endodontic instruments. The modeled instrument containing only R-phase demanded the lowest moment to be bent, followed by the one with mixed austenite + R-phase. The superelastic instrument, containing essentially austenite, required the highest bending moment. During bending, the fully R-phased instrument reached the lowest stress values; however, it also experienced the highest angular deflection when subjected to torsion. In summary, this simulation showed that NiTi endodontic instruments containing only R-phase in their microstructure would show higher flexibility without compromising their performance under torsion.
format Online
Article
Text
id pubmed-4893430
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-48934302016-06-16 Effects of R-Phase on Mechanical Responses of a Nickel-Titanium Endodontic Instrument: Structural Characterization and Finite Element Analysis Santos, Leandro de Arruda Resende, Pedro Damas Bahia, Maria Guiomar de Azevedo Buono, Vicente Tadeu Lopes ScientificWorldJournal Research Article The effects of the presence of the R-phase in a near-equiatomic NiTi alloy on the mechanical responses of an endodontic instrument were studied by using finite element analysis. The input data for the constitutive model in the simulation were obtained by tensile testing of three NiTi wires: superelastic austenite NiTi, austenite + R-phase NiTi, and fully R-phased NiTi. The wires were also characterized by X-ray diffraction and differential scanning calorimetry. A commercially available endodontic instrument was scanned using microcomputed tomography, and the resulting images were used to build the geometrical model. The numerical analyses were performed in ABAQUS using load and boundary conditions based on the ISO 3630-1 specification for the bending and torsion of endodontic instruments. The modeled instrument containing only R-phase demanded the lowest moment to be bent, followed by the one with mixed austenite + R-phase. The superelastic instrument, containing essentially austenite, required the highest bending moment. During bending, the fully R-phased instrument reached the lowest stress values; however, it also experienced the highest angular deflection when subjected to torsion. In summary, this simulation showed that NiTi endodontic instruments containing only R-phase in their microstructure would show higher flexibility without compromising their performance under torsion. Hindawi Publishing Corporation 2016 2016-05-22 /pmc/articles/PMC4893430/ /pubmed/27314059 http://dx.doi.org/10.1155/2016/7617493 Text en Copyright © 2016 Leandro de Arruda Santos et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Santos, Leandro de Arruda
Resende, Pedro Damas
Bahia, Maria Guiomar de Azevedo
Buono, Vicente Tadeu Lopes
Effects of R-Phase on Mechanical Responses of a Nickel-Titanium Endodontic Instrument: Structural Characterization and Finite Element Analysis
title Effects of R-Phase on Mechanical Responses of a Nickel-Titanium Endodontic Instrument: Structural Characterization and Finite Element Analysis
title_full Effects of R-Phase on Mechanical Responses of a Nickel-Titanium Endodontic Instrument: Structural Characterization and Finite Element Analysis
title_fullStr Effects of R-Phase on Mechanical Responses of a Nickel-Titanium Endodontic Instrument: Structural Characterization and Finite Element Analysis
title_full_unstemmed Effects of R-Phase on Mechanical Responses of a Nickel-Titanium Endodontic Instrument: Structural Characterization and Finite Element Analysis
title_short Effects of R-Phase on Mechanical Responses of a Nickel-Titanium Endodontic Instrument: Structural Characterization and Finite Element Analysis
title_sort effects of r-phase on mechanical responses of a nickel-titanium endodontic instrument: structural characterization and finite element analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4893430/
https://www.ncbi.nlm.nih.gov/pubmed/27314059
http://dx.doi.org/10.1155/2016/7617493
work_keys_str_mv AT santosleandrodearruda effectsofrphaseonmechanicalresponsesofanickeltitaniumendodonticinstrumentstructuralcharacterizationandfiniteelementanalysis
AT resendepedrodamas effectsofrphaseonmechanicalresponsesofanickeltitaniumendodonticinstrumentstructuralcharacterizationandfiniteelementanalysis
AT bahiamariaguiomardeazevedo effectsofrphaseonmechanicalresponsesofanickeltitaniumendodonticinstrumentstructuralcharacterizationandfiniteelementanalysis
AT buonovicentetadeulopes effectsofrphaseonmechanicalresponsesofanickeltitaniumendodonticinstrumentstructuralcharacterizationandfiniteelementanalysis