Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology
Recent developments for a new spectral irradiance scale realization at the National Institute of Standards and Technology have been targeted to reduce the present relative expanded uncertainties of 0.67 % to 4.34 % (coverage factor of k = 2 and thus a 2 standard deviation estimate) in the spectral i...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
[Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
1997
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4894581/ https://www.ncbi.nlm.nih.gov/pubmed/27805142 http://dx.doi.org/10.6028/jres.102.036 |
_version_ | 1782435690728914944 |
---|---|
author | Tsai, Benjamin K. |
author_facet | Tsai, Benjamin K. |
author_sort | Tsai, Benjamin K. |
collection | PubMed |
description | Recent developments for a new spectral irradiance scale realization at the National Institute of Standards and Technology have been targeted to reduce the present relative expanded uncertainties of 0.67 % to 4.34 % (coverage factor of k = 2 and thus a 2 standard deviation estimate) in the spectral irradiance scale to 0.17 % for the range from 350 nm to 1100 nm. To accomplish this goal, a suite of filter radiometers calibrated using NIST’s high accuracy cryogenic radiometer have been used to measure the temperature of a high-temperature black-body. A comparison of the filter radiometer calibrations with the spectral irradiance scale along with an evaluation of the black-body calibration technique have been performed. With the aid of a monochromator, the calibrated filter radiometers will then be utilized to calibrate primary and secondary spectral irradiance standard lamps at NIST. |
format | Online Article Text |
id | pubmed-4894581 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1997 |
publisher | [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology |
record_format | MEDLINE/PubMed |
spelling | pubmed-48945812016-10-28 Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology Tsai, Benjamin K. J Res Natl Inst Stand Technol Article Recent developments for a new spectral irradiance scale realization at the National Institute of Standards and Technology have been targeted to reduce the present relative expanded uncertainties of 0.67 % to 4.34 % (coverage factor of k = 2 and thus a 2 standard deviation estimate) in the spectral irradiance scale to 0.17 % for the range from 350 nm to 1100 nm. To accomplish this goal, a suite of filter radiometers calibrated using NIST’s high accuracy cryogenic radiometer have been used to measure the temperature of a high-temperature black-body. A comparison of the filter radiometer calibrations with the spectral irradiance scale along with an evaluation of the black-body calibration technique have been performed. With the aid of a monochromator, the calibrated filter radiometers will then be utilized to calibrate primary and secondary spectral irradiance standard lamps at NIST. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1997 /pmc/articles/PMC4894581/ /pubmed/27805142 http://dx.doi.org/10.6028/jres.102.036 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright. |
spellingShingle | Article Tsai, Benjamin K. Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology |
title | Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology |
title_full | Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology |
title_fullStr | Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology |
title_full_unstemmed | Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology |
title_short | Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology |
title_sort | developments for a new spectral irradiance scale at the national institute of standards and technology |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4894581/ https://www.ncbi.nlm.nih.gov/pubmed/27805142 http://dx.doi.org/10.6028/jres.102.036 |
work_keys_str_mv | AT tsaibenjamink developmentsforanewspectralirradiancescaleatthenationalinstituteofstandardsandtechnology |