Cargando…

Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology

Recent developments for a new spectral irradiance scale realization at the National Institute of Standards and Technology have been targeted to reduce the present relative expanded uncertainties of 0.67 % to 4.34 % (coverage factor of k = 2 and thus a 2 standard deviation estimate) in the spectral i...

Descripción completa

Detalles Bibliográficos
Autor principal: Tsai, Benjamin K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1997
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4894581/
https://www.ncbi.nlm.nih.gov/pubmed/27805142
http://dx.doi.org/10.6028/jres.102.036
_version_ 1782435690728914944
author Tsai, Benjamin K.
author_facet Tsai, Benjamin K.
author_sort Tsai, Benjamin K.
collection PubMed
description Recent developments for a new spectral irradiance scale realization at the National Institute of Standards and Technology have been targeted to reduce the present relative expanded uncertainties of 0.67 % to 4.34 % (coverage factor of k = 2 and thus a 2 standard deviation estimate) in the spectral irradiance scale to 0.17 % for the range from 350 nm to 1100 nm. To accomplish this goal, a suite of filter radiometers calibrated using NIST’s high accuracy cryogenic radiometer have been used to measure the temperature of a high-temperature black-body. A comparison of the filter radiometer calibrations with the spectral irradiance scale along with an evaluation of the black-body calibration technique have been performed. With the aid of a monochromator, the calibrated filter radiometers will then be utilized to calibrate primary and secondary spectral irradiance standard lamps at NIST.
format Online
Article
Text
id pubmed-4894581
institution National Center for Biotechnology Information
language English
publishDate 1997
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-48945812016-10-28 Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology Tsai, Benjamin K. J Res Natl Inst Stand Technol Article Recent developments for a new spectral irradiance scale realization at the National Institute of Standards and Technology have been targeted to reduce the present relative expanded uncertainties of 0.67 % to 4.34 % (coverage factor of k = 2 and thus a 2 standard deviation estimate) in the spectral irradiance scale to 0.17 % for the range from 350 nm to 1100 nm. To accomplish this goal, a suite of filter radiometers calibrated using NIST’s high accuracy cryogenic radiometer have been used to measure the temperature of a high-temperature black-body. A comparison of the filter radiometer calibrations with the spectral irradiance scale along with an evaluation of the black-body calibration technique have been performed. With the aid of a monochromator, the calibrated filter radiometers will then be utilized to calibrate primary and secondary spectral irradiance standard lamps at NIST. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1997 /pmc/articles/PMC4894581/ /pubmed/27805142 http://dx.doi.org/10.6028/jres.102.036 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Tsai, Benjamin K.
Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology
title Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology
title_full Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology
title_fullStr Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology
title_full_unstemmed Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology
title_short Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology
title_sort developments for a new spectral irradiance scale at the national institute of standards and technology
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4894581/
https://www.ncbi.nlm.nih.gov/pubmed/27805142
http://dx.doi.org/10.6028/jres.102.036
work_keys_str_mv AT tsaibenjamink developmentsforanewspectralirradiancescaleatthenationalinstituteofstandardsandtechnology