Radiometric Measurement Comparison Using the Ocean Color Temperature Scanner (OCTS) Visible and Near Infrared Integrating Sphere
As a part of the pre-flight calibration and validation activities for the Ocean Color and Temperature Scanner (OCTS) and the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) ocean color satellite instruments, a radiometric measurement comparison was held in February 1995 at the NEC Corporation in Yok...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
[Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
1997
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4894588/ https://www.ncbi.nlm.nih.gov/pubmed/27805113 http://dx.doi.org/10.6028/jres.102.043 |
_version_ | 1782435692302827520 |
---|---|
author | Johnson, B. Carol Sakuma, F. Butler, J. J. Biggar, S. F. Cooper, J. W. Ishida, J. Suzuki, K. |
author_facet | Johnson, B. Carol Sakuma, F. Butler, J. J. Biggar, S. F. Cooper, J. W. Ishida, J. Suzuki, K. |
author_sort | Johnson, B. Carol |
collection | PubMed |
description | As a part of the pre-flight calibration and validation activities for the Ocean Color and Temperature Scanner (OCTS) and the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) ocean color satellite instruments, a radiometric measurement comparison was held in February 1995 at the NEC Corporation in Yokohama, Japan. Researchers from the National Institute of Standards and Technology (NIST), the National Aeronautics and Space Administration/Goddard Space Flight Center (NASA/GSFC), the University of Arizona Optical Sciences Center (UA), and the National Research Laboratory of Metrology (NRLM) in Tsukuba, Japan used their portable radiometers to measure the spectral radiance of the OCTS visible and near-infrared integrating sphere at four radiance levels. These four levels corresponded to the configuration of the OCTS integrating sphere when the calibration coefficients for five of the eight spectral channels, or bands, of the OCTS instrument were determined. The measurements of the four radiometers differed by −2.7 % to 3.9 % when compared to the NEC calibration of the sphere and the overall agreement was within the combined measurement uncertainties. A comparison of the measurements from the participating radiometers also resulted in agreement within the combined measurement uncertainties. These results are encouraging and demonstrate the utility of comparisons using laboratory calibration integrating sphere sources. Other comparisons will focus on instruments that are scheduled for spacecraft in the NASA study of climate change, the Earth Observing System (EOS). |
format | Online Article Text |
id | pubmed-4894588 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1997 |
publisher | [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology |
record_format | MEDLINE/PubMed |
spelling | pubmed-48945882016-10-28 Radiometric Measurement Comparison Using the Ocean Color Temperature Scanner (OCTS) Visible and Near Infrared Integrating Sphere Johnson, B. Carol Sakuma, F. Butler, J. J. Biggar, S. F. Cooper, J. W. Ishida, J. Suzuki, K. J Res Natl Inst Stand Technol Article As a part of the pre-flight calibration and validation activities for the Ocean Color and Temperature Scanner (OCTS) and the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) ocean color satellite instruments, a radiometric measurement comparison was held in February 1995 at the NEC Corporation in Yokohama, Japan. Researchers from the National Institute of Standards and Technology (NIST), the National Aeronautics and Space Administration/Goddard Space Flight Center (NASA/GSFC), the University of Arizona Optical Sciences Center (UA), and the National Research Laboratory of Metrology (NRLM) in Tsukuba, Japan used their portable radiometers to measure the spectral radiance of the OCTS visible and near-infrared integrating sphere at four radiance levels. These four levels corresponded to the configuration of the OCTS integrating sphere when the calibration coefficients for five of the eight spectral channels, or bands, of the OCTS instrument were determined. The measurements of the four radiometers differed by −2.7 % to 3.9 % when compared to the NEC calibration of the sphere and the overall agreement was within the combined measurement uncertainties. A comparison of the measurements from the participating radiometers also resulted in agreement within the combined measurement uncertainties. These results are encouraging and demonstrate the utility of comparisons using laboratory calibration integrating sphere sources. Other comparisons will focus on instruments that are scheduled for spacecraft in the NASA study of climate change, the Earth Observing System (EOS). [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1997 /pmc/articles/PMC4894588/ /pubmed/27805113 http://dx.doi.org/10.6028/jres.102.043 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright. |
spellingShingle | Article Johnson, B. Carol Sakuma, F. Butler, J. J. Biggar, S. F. Cooper, J. W. Ishida, J. Suzuki, K. Radiometric Measurement Comparison Using the Ocean Color Temperature Scanner (OCTS) Visible and Near Infrared Integrating Sphere |
title | Radiometric Measurement Comparison Using the Ocean Color Temperature Scanner (OCTS) Visible and Near Infrared Integrating Sphere |
title_full | Radiometric Measurement Comparison Using the Ocean Color Temperature Scanner (OCTS) Visible and Near Infrared Integrating Sphere |
title_fullStr | Radiometric Measurement Comparison Using the Ocean Color Temperature Scanner (OCTS) Visible and Near Infrared Integrating Sphere |
title_full_unstemmed | Radiometric Measurement Comparison Using the Ocean Color Temperature Scanner (OCTS) Visible and Near Infrared Integrating Sphere |
title_short | Radiometric Measurement Comparison Using the Ocean Color Temperature Scanner (OCTS) Visible and Near Infrared Integrating Sphere |
title_sort | radiometric measurement comparison using the ocean color temperature scanner (octs) visible and near infrared integrating sphere |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4894588/ https://www.ncbi.nlm.nih.gov/pubmed/27805113 http://dx.doi.org/10.6028/jres.102.043 |
work_keys_str_mv | AT johnsonbcarol radiometricmeasurementcomparisonusingtheoceancolortemperaturescanneroctsvisibleandnearinfraredintegratingsphere AT sakumaf radiometricmeasurementcomparisonusingtheoceancolortemperaturescanneroctsvisibleandnearinfraredintegratingsphere AT butlerjj radiometricmeasurementcomparisonusingtheoceancolortemperaturescanneroctsvisibleandnearinfraredintegratingsphere AT biggarsf radiometricmeasurementcomparisonusingtheoceancolortemperaturescanneroctsvisibleandnearinfraredintegratingsphere AT cooperjw radiometricmeasurementcomparisonusingtheoceancolortemperaturescanneroctsvisibleandnearinfraredintegratingsphere AT ishidaj radiometricmeasurementcomparisonusingtheoceancolortemperaturescanneroctsvisibleandnearinfraredintegratingsphere AT suzukik radiometricmeasurementcomparisonusingtheoceancolortemperaturescanneroctsvisibleandnearinfraredintegratingsphere |