Radiometric Measurement Comparison Using the Ocean Color Temperature Scanner (OCTS) Visible and Near Infrared Integrating Sphere

As a part of the pre-flight calibration and validation activities for the Ocean Color and Temperature Scanner (OCTS) and the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) ocean color satellite instruments, a radiometric measurement comparison was held in February 1995 at the NEC Corporation in Yok...

Descripción completa

Detalles Bibliográficos
Autores principales: Johnson, B. Carol, Sakuma, F., Butler, J. J., Biggar, S. F., Cooper, J. W., Ishida, J., Suzuki, K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1997
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4894588/
https://www.ncbi.nlm.nih.gov/pubmed/27805113
http://dx.doi.org/10.6028/jres.102.043
_version_ 1782435692302827520
author Johnson, B. Carol
Sakuma, F.
Butler, J. J.
Biggar, S. F.
Cooper, J. W.
Ishida, J.
Suzuki, K.
author_facet Johnson, B. Carol
Sakuma, F.
Butler, J. J.
Biggar, S. F.
Cooper, J. W.
Ishida, J.
Suzuki, K.
author_sort Johnson, B. Carol
collection PubMed
description As a part of the pre-flight calibration and validation activities for the Ocean Color and Temperature Scanner (OCTS) and the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) ocean color satellite instruments, a radiometric measurement comparison was held in February 1995 at the NEC Corporation in Yokohama, Japan. Researchers from the National Institute of Standards and Technology (NIST), the National Aeronautics and Space Administration/Goddard Space Flight Center (NASA/GSFC), the University of Arizona Optical Sciences Center (UA), and the National Research Laboratory of Metrology (NRLM) in Tsukuba, Japan used their portable radiometers to measure the spectral radiance of the OCTS visible and near-infrared integrating sphere at four radiance levels. These four levels corresponded to the configuration of the OCTS integrating sphere when the calibration coefficients for five of the eight spectral channels, or bands, of the OCTS instrument were determined. The measurements of the four radiometers differed by −2.7 % to 3.9 % when compared to the NEC calibration of the sphere and the overall agreement was within the combined measurement uncertainties. A comparison of the measurements from the participating radiometers also resulted in agreement within the combined measurement uncertainties. These results are encouraging and demonstrate the utility of comparisons using laboratory calibration integrating sphere sources. Other comparisons will focus on instruments that are scheduled for spacecraft in the NASA study of climate change, the Earth Observing System (EOS).
format Online
Article
Text
id pubmed-4894588
institution National Center for Biotechnology Information
language English
publishDate 1997
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-48945882016-10-28 Radiometric Measurement Comparison Using the Ocean Color Temperature Scanner (OCTS) Visible and Near Infrared Integrating Sphere Johnson, B. Carol Sakuma, F. Butler, J. J. Biggar, S. F. Cooper, J. W. Ishida, J. Suzuki, K. J Res Natl Inst Stand Technol Article As a part of the pre-flight calibration and validation activities for the Ocean Color and Temperature Scanner (OCTS) and the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) ocean color satellite instruments, a radiometric measurement comparison was held in February 1995 at the NEC Corporation in Yokohama, Japan. Researchers from the National Institute of Standards and Technology (NIST), the National Aeronautics and Space Administration/Goddard Space Flight Center (NASA/GSFC), the University of Arizona Optical Sciences Center (UA), and the National Research Laboratory of Metrology (NRLM) in Tsukuba, Japan used their portable radiometers to measure the spectral radiance of the OCTS visible and near-infrared integrating sphere at four radiance levels. These four levels corresponded to the configuration of the OCTS integrating sphere when the calibration coefficients for five of the eight spectral channels, or bands, of the OCTS instrument were determined. The measurements of the four radiometers differed by −2.7 % to 3.9 % when compared to the NEC calibration of the sphere and the overall agreement was within the combined measurement uncertainties. A comparison of the measurements from the participating radiometers also resulted in agreement within the combined measurement uncertainties. These results are encouraging and demonstrate the utility of comparisons using laboratory calibration integrating sphere sources. Other comparisons will focus on instruments that are scheduled for spacecraft in the NASA study of climate change, the Earth Observing System (EOS). [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1997 /pmc/articles/PMC4894588/ /pubmed/27805113 http://dx.doi.org/10.6028/jres.102.043 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Johnson, B. Carol
Sakuma, F.
Butler, J. J.
Biggar, S. F.
Cooper, J. W.
Ishida, J.
Suzuki, K.
Radiometric Measurement Comparison Using the Ocean Color Temperature Scanner (OCTS) Visible and Near Infrared Integrating Sphere
title Radiometric Measurement Comparison Using the Ocean Color Temperature Scanner (OCTS) Visible and Near Infrared Integrating Sphere
title_full Radiometric Measurement Comparison Using the Ocean Color Temperature Scanner (OCTS) Visible and Near Infrared Integrating Sphere
title_fullStr Radiometric Measurement Comparison Using the Ocean Color Temperature Scanner (OCTS) Visible and Near Infrared Integrating Sphere
title_full_unstemmed Radiometric Measurement Comparison Using the Ocean Color Temperature Scanner (OCTS) Visible and Near Infrared Integrating Sphere
title_short Radiometric Measurement Comparison Using the Ocean Color Temperature Scanner (OCTS) Visible and Near Infrared Integrating Sphere
title_sort radiometric measurement comparison using the ocean color temperature scanner (octs) visible and near infrared integrating sphere
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4894588/
https://www.ncbi.nlm.nih.gov/pubmed/27805113
http://dx.doi.org/10.6028/jres.102.043
work_keys_str_mv AT johnsonbcarol radiometricmeasurementcomparisonusingtheoceancolortemperaturescanneroctsvisibleandnearinfraredintegratingsphere
AT sakumaf radiometricmeasurementcomparisonusingtheoceancolortemperaturescanneroctsvisibleandnearinfraredintegratingsphere
AT butlerjj radiometricmeasurementcomparisonusingtheoceancolortemperaturescanneroctsvisibleandnearinfraredintegratingsphere
AT biggarsf radiometricmeasurementcomparisonusingtheoceancolortemperaturescanneroctsvisibleandnearinfraredintegratingsphere
AT cooperjw radiometricmeasurementcomparisonusingtheoceancolortemperaturescanneroctsvisibleandnearinfraredintegratingsphere
AT ishidaj radiometricmeasurementcomparisonusingtheoceancolortemperaturescanneroctsvisibleandnearinfraredintegratingsphere
AT suzukik radiometricmeasurementcomparisonusingtheoceancolortemperaturescanneroctsvisibleandnearinfraredintegratingsphere