Cargando…

Comparison of Serum Concentrations of Symmetric Dimethylarginine and Creatinine as Kidney Function Biomarkers in Cats with Chronic Kidney Disease

BACKGROUND: Symmetric dimethylarginine (SDMA) has been shown to be an accurate and precise biomarker for calculating estimated glomerular filtration rate (GFR) in humans, as well as a more sensitive biomarker than serum creatinine concentration (sCr) for assessing renal dysfunction. OBJECTIVES: The...

Descripción completa

Detalles Bibliográficos
Autores principales: Hall, J.A., Yerramilli, M., Obare, E., Jewell, D.E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4895610/
https://www.ncbi.nlm.nih.gov/pubmed/25231385
http://dx.doi.org/10.1111/jvim.12445
_version_ 1782435885419069440
author Hall, J.A.
Yerramilli, M.
Obare, E.
Yerramilli, M.
Jewell, D.E.
author_facet Hall, J.A.
Yerramilli, M.
Obare, E.
Yerramilli, M.
Jewell, D.E.
author_sort Hall, J.A.
collection PubMed
description BACKGROUND: Symmetric dimethylarginine (SDMA) has been shown to be an accurate and precise biomarker for calculating estimated glomerular filtration rate (GFR) in humans, as well as a more sensitive biomarker than serum creatinine concentration (sCr) for assessing renal dysfunction. OBJECTIVES: The purpose of this retrospective study was to report on the utility of measuring serum SDMA concentrations in cats for detection of chronic kidney disease (CKD) before diagnosis by conventional measurement of sCr. ANIMALS: Chronic kidney disease cats (n = 21) included those persistently azotemic for ≥3 months (n = 15), nonazotemic cats with GFR >30% decreased from median GFR of normal cats (n = 4), and nonazotemic cats with calcium oxalate kidney stones (n = 2). Healthy geriatric cats (n = 21) were selected from the same colony. METHODS: Symmetric dimethylarginine concentrations (liquid chromatography‐mass spectroscopy) and sCr (enzymatic colorimetry) were determined retrospectively from historical data or banked serum samples in azotemic cats or at the time GFR (iohexol clearance) was measured in nonazotemic cats. RESULTS: Serum SDMA (r = −0.79) and sCr (r = −0.77) concentrations were significantly correlated to GFR (both P < .0001). Symmetric dimethylarginine became increased before sCr in 17/21 cats (mean, 17.0 months; range, 1.5–48 months). Serum SDMA had higher sensitivity (100%) compared with sCr (17%), but lower specificity (91% versus 100%) and positive predictive value (86% versus 100%). CONCLUSION AND CLINICAL IMPORTANCE: Using serum SDMA as a biomarker for CKD allows earlier detection of CKD in cats compared with sCr, which may be desirable for initiating renoprotective interventions that slow progression of CKD.
format Online
Article
Text
id pubmed-4895610
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-48956102016-06-22 Comparison of Serum Concentrations of Symmetric Dimethylarginine and Creatinine as Kidney Function Biomarkers in Cats with Chronic Kidney Disease Hall, J.A. Yerramilli, M. Obare, E. Yerramilli, M. Jewell, D.E. J Vet Intern Med Standard Articles BACKGROUND: Symmetric dimethylarginine (SDMA) has been shown to be an accurate and precise biomarker for calculating estimated glomerular filtration rate (GFR) in humans, as well as a more sensitive biomarker than serum creatinine concentration (sCr) for assessing renal dysfunction. OBJECTIVES: The purpose of this retrospective study was to report on the utility of measuring serum SDMA concentrations in cats for detection of chronic kidney disease (CKD) before diagnosis by conventional measurement of sCr. ANIMALS: Chronic kidney disease cats (n = 21) included those persistently azotemic for ≥3 months (n = 15), nonazotemic cats with GFR >30% decreased from median GFR of normal cats (n = 4), and nonazotemic cats with calcium oxalate kidney stones (n = 2). Healthy geriatric cats (n = 21) were selected from the same colony. METHODS: Symmetric dimethylarginine concentrations (liquid chromatography‐mass spectroscopy) and sCr (enzymatic colorimetry) were determined retrospectively from historical data or banked serum samples in azotemic cats or at the time GFR (iohexol clearance) was measured in nonazotemic cats. RESULTS: Serum SDMA (r = −0.79) and sCr (r = −0.77) concentrations were significantly correlated to GFR (both P < .0001). Symmetric dimethylarginine became increased before sCr in 17/21 cats (mean, 17.0 months; range, 1.5–48 months). Serum SDMA had higher sensitivity (100%) compared with sCr (17%), but lower specificity (91% versus 100%) and positive predictive value (86% versus 100%). CONCLUSION AND CLINICAL IMPORTANCE: Using serum SDMA as a biomarker for CKD allows earlier detection of CKD in cats compared with sCr, which may be desirable for initiating renoprotective interventions that slow progression of CKD. John Wiley and Sons Inc. 2014-09-17 2014 /pmc/articles/PMC4895610/ /pubmed/25231385 http://dx.doi.org/10.1111/jvim.12445 Text en Copyright © 2014 by the American College of Veterinary Internal Medicine
spellingShingle Standard Articles
Hall, J.A.
Yerramilli, M.
Obare, E.
Yerramilli, M.
Jewell, D.E.
Comparison of Serum Concentrations of Symmetric Dimethylarginine and Creatinine as Kidney Function Biomarkers in Cats with Chronic Kidney Disease
title Comparison of Serum Concentrations of Symmetric Dimethylarginine and Creatinine as Kidney Function Biomarkers in Cats with Chronic Kidney Disease
title_full Comparison of Serum Concentrations of Symmetric Dimethylarginine and Creatinine as Kidney Function Biomarkers in Cats with Chronic Kidney Disease
title_fullStr Comparison of Serum Concentrations of Symmetric Dimethylarginine and Creatinine as Kidney Function Biomarkers in Cats with Chronic Kidney Disease
title_full_unstemmed Comparison of Serum Concentrations of Symmetric Dimethylarginine and Creatinine as Kidney Function Biomarkers in Cats with Chronic Kidney Disease
title_short Comparison of Serum Concentrations of Symmetric Dimethylarginine and Creatinine as Kidney Function Biomarkers in Cats with Chronic Kidney Disease
title_sort comparison of serum concentrations of symmetric dimethylarginine and creatinine as kidney function biomarkers in cats with chronic kidney disease
topic Standard Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4895610/
https://www.ncbi.nlm.nih.gov/pubmed/25231385
http://dx.doi.org/10.1111/jvim.12445
work_keys_str_mv AT hallja comparisonofserumconcentrationsofsymmetricdimethylarginineandcreatinineaskidneyfunctionbiomarkersincatswithchronickidneydisease
AT yerramillim comparisonofserumconcentrationsofsymmetricdimethylarginineandcreatinineaskidneyfunctionbiomarkersincatswithchronickidneydisease
AT obaree comparisonofserumconcentrationsofsymmetricdimethylarginineandcreatinineaskidneyfunctionbiomarkersincatswithchronickidneydisease
AT yerramillim comparisonofserumconcentrationsofsymmetricdimethylarginineandcreatinineaskidneyfunctionbiomarkersincatswithchronickidneydisease
AT jewellde comparisonofserumconcentrationsofsymmetricdimethylarginineandcreatinineaskidneyfunctionbiomarkersincatswithchronickidneydisease